Device Validation of Augmented-Reality ICG Fluorescence Imaging for Sentinel Lymph Node Detection in Breast Cancer

2026. június 28. frissítette: Borislav Kondov, Ss. Cyril and Methodius University of Skopje

Validation of Augmented-Reality/Virtual-Reality Goggle-Based Near-Infrared Fluorescence Imaging for Sentinel Lymph Node Detection in Patients With Breast Cancer

This study evaluates how accurately augmented-reality goggles with indocyanine green (ICG) near-infrared fluorescence can identify sentinel (first-draining) lymph nodes during breast cancer surgery. The goggles and ICG signal are used to mark candidate sentinel nodes, and an additional observer may record near-infrared images during the operation for device-performance assessment. These imaging findings do not change the surgical procedure. The candidate nodes and all removed tissue are examined by histopathology, which serves as the reference standard. Two hundred patients undergoing breast cancer surgery will take part. The study measures how well the goggle-based imaging detects nodes that contain cancer, compared with final pathology.

A tanulmány áttekintése

Részletes leírás

This is a prospective observational device-validation study in patients undergoing breast cancer surgery with axillary evaluation. Augmented-reality goggle-based near-infrared fluorescence imaging with ICG is used to visualize and mark candidate sentinel lymph nodes. Intraoperative near-infrared imaging may be performed by an observer who is not the operating surgeon, solely to assess device performance; observer findings are not communicated to the operating surgeon before wound closure and do not influence the operation. All marked nodes and removed tissue undergo histopathology, which serves as the blinded reference standard. Device performance is assessed on consecutive eligible patients within defined enrollment windows; for each near-infrared imaging device, sensitivity, specificity, positive and negative predictive value, and node-level ROC analysis are estimated against final histopathology, with confidence intervals accounting for clustering of nodes within patients. The study is non-interventional: the imaging does not alter surgical management.

Tanulmány típusa

Megfigyelő

Beiratkozás (Becsült)

200

Kapcsolatok és helyek

Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.

Tanulmányi kapcsolat

Tanulmányozza a kapcsolattartók biztonsági mentését

Tanulmányi helyek

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

  • Felnőtt
  • Idősebb felnőtt

Egészséges önkénteseket fogad

Nem

Mintavételi módszer

Nem valószínűségi minta

Tanulmányi populáció

Patients with histologically proven breast cancer undergoing surgery with axillary lymph node evaluation at the participating center, enrolled consecutively.

Leírás

Inclusion Criteria:

  • Histologically proven breast cancer
  • Age 18 years or older
  • Undergoing breast cancer surgery with sentinel lymph node evaluation and/or axillary lymph node dissection
  • Provides written informed consent

Exclusion Criteria:

  • Pregnancy
  • Neoadjuvant chemotherapy
  • Prior breast surgery
  • Iodine or seafood allergy
  • Indocyanine green (ICG) allergy
  • Declines or is unable to provide informed consent

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

Kohorszok és beavatkozások

Csoport / Kohorsz
Beavatkozás / kezelés
Breast cancer patients undergoing surgery with AR-ICG node imaging
Patients undergoing breast cancer surgery in whom AR-ICG goggle-based near-infrared imaging is used to mark candidate sentinel nodes, with optional observer near-infrared imaging for device-performance assessment; histopathology is the reference standard.
Augmented-reality goggle-based near-infrared fluorescence imaging with indocyanine green (ICG), used to visualize and mark candidate sentinel lymph nodes during breast cancer surgery. Intraoperative near-infrared imaging may also be recorded by an observer for device-performance assessment. Imaging does not alter surgical management; histopathology serves as the reference standard.

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
Node-level diagnostic accuracy of AR-ICG fluorescence imaging versus histopathology
Időkeret: From surgery to final histopathology (up to ~2 weeks after surgery)
Sensitivity, specificity, positive and negative predictive value, and area under the ROC curve for goggle-based near-infrared fluorescence detection of tumor-positive lymph nodes, using final histopathology as the reference standard, with confidence intervals accounting for clustering of nodes within patients.
From surgery to final histopathology (up to ~2 weeks after surgery)

Másodlagos eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
Patient-level sentinel-node detection rate
Időkeret: Final histopathology (up to approximately 2 weeks after surgery)
Proportion of patients in whom at least one sentinel lymph node is identified by AR-ICG near-infrared fluorescence imaging.
Final histopathology (up to approximately 2 weeks after surgery)
Concordance of device-marked nodes with histopathology
Időkeret: Final histopathology (up to approximately 2 weeks after surgery)
Agreement between lymph nodes marked by AR-ICG fluorescence imaging and nodal status confirmed on final histopathology.
Final histopathology (up to approximately 2 weeks after surgery)
Per-device diagnostic performance across near-infrared imaging systems
Időkeret: Through study completion (up to approximately 24 months)
Sensitivity, specificity, positive predictive value, negative predictive value, and area under the ROC curve estimated separately for each near-infrared imaging device evaluated, using final histopathology as the reference standard, on consecutive eligible patients within defined enrollment windows.
Through study completion (up to approximately 24 months)
False-negative rate of AR-ICG fluorescence node detection
Időkeret: Final histopathology (up to approximately 2 weeks after surgery)
Proportion of pathology-confirmed tumor-positive lymph nodes not identified as fluorescent by AR-ICG imaging.
Final histopathology (up to approximately 2 weeks after surgery)
Number of candidate sentinel nodes identified per patient
Időkeret: Intraoperative (day of surgery)
Number of candidate sentinel lymph nodes marked by AR-ICG fluorescence imaging per patient (count).
Intraoperative (day of surgery)

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Publikációk és hasznos linkek

A vizsgálattal kapcsolatos információk beviteléért felelős személy önkéntesen bocsátja rendelkezésre ezeket a kiadványokat. Ezek bármiről szólhatnak, ami a tanulmányhoz kapcsolódik.

Általános kiadványok

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete (Becsült)

2026. július 1.

Elsődleges befejezés (Becsült)

2028. július 1.

A tanulmány befejezése (Becsült)

2028. december 31.

Tanulmányi regisztráció dátumai

Először benyújtva

2026. június 28.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2026. június 28.

Első közzététel (Tényleges)

2026. július 6.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Tényleges)

2026. július 6.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2026. június 28.

Utolsó ellenőrzés

2026. június 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

Terv az egyéni résztvevői adatokhoz (IPD)

Tervezi megosztani az egyéni résztvevői adatokat (IPD)?

NEM

IPD terv leírása

This is a single-center observational device-validation study. Individual participant data are not planned to be shared. De-identified data may be made available from the principal investigator on reasonable request, subject to institutional approval.

Gyógyszer- és eszközinformációk, tanulmányi dokumentumok

Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz

Nem

Egy amerikai FDA által szabályozott eszközterméket tanulmányoz

Nem

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .

Iratkozz fel