Validation of Augmented-Reality/Virtual-Reality Goggle-Based Near-Infrared Fluorescence Imaging for Sentinel Lymph Node Detection in Patients With Breast Cancer

This study evaluates how accurately augmented-reality goggles with indocyanine green (ICG) near-infrared fluorescence can identify sentinel (first-draining) lymph nodes during breast cancer surgery. The goggles and ICG signal are used to mark candidate sentinel nodes, and an additional observer may record near-infrared images during the operation for device-performance assessment. These imaging findings do not change the surgical procedure. The candidate nodes and all removed tissue are examined by histopathology, which serves as the reference standard. Two hundred patients undergoing breast cancer surgery will take part. The study measures how well the goggle-based imaging detects nodes that contain cancer, compared with final pathology.

Обзор исследования

Подробное описание

This is a prospective observational device-validation study in patients undergoing breast cancer surgery with axillary evaluation. Augmented-reality goggle-based near-infrared fluorescence imaging with ICG is used to visualize and mark candidate sentinel lymph nodes. Intraoperative near-infrared imaging may be performed by an observer who is not the operating surgeon, solely to assess device performance; observer findings are not communicated to the operating surgeon before wound closure and do not influence the operation. All marked nodes and removed tissue undergo histopathology, which serves as the blinded reference standard. Device performance is assessed on consecutive eligible patients within defined enrollment windows; for each near-infrared imaging device, sensitivity, specificity, positive and negative predictive value, and node-level ROC analysis are estimated against final histopathology, with confidence intervals accounting for clustering of nodes within patients. The study is non-interventional: the imaging does not alter surgical management.

Тип исследования

Наблюдательный

Регистрация (Оцененный)

200

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Контакты исследования

Учебное резервное копирование контактов

Места учебы

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Нет

Метод выборки

Невероятностная выборка

Исследуемая популяция

Patients with histologically proven breast cancer undergoing surgery with axillary lymph node evaluation at the participating center, enrolled consecutively.

Описание

Inclusion Criteria:

  • Histologically proven breast cancer
  • Age 18 years or older
  • Undergoing breast cancer surgery with sentinel lymph node evaluation and/or axillary lymph node dissection
  • Provides written informed consent

Exclusion Criteria:

  • Pregnancy
  • Neoadjuvant chemotherapy
  • Prior breast surgery
  • Iodine or seafood allergy
  • Indocyanine green (ICG) allergy
  • Declines or is unable to provide informed consent

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

Когорты и вмешательства

Группа / когорта
Вмешательство/лечение
Breast cancer patients undergoing surgery with AR-ICG node imaging
Patients undergoing breast cancer surgery in whom AR-ICG goggle-based near-infrared imaging is used to mark candidate sentinel nodes, with optional observer near-infrared imaging for device-performance assessment; histopathology is the reference standard.
Augmented-reality goggle-based near-infrared fluorescence imaging with indocyanine green (ICG), used to visualize and mark candidate sentinel lymph nodes during breast cancer surgery. Intraoperative near-infrared imaging may also be recorded by an observer for device-performance assessment. Imaging does not alter surgical management; histopathology serves as the reference standard.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Node-level diagnostic accuracy of AR-ICG fluorescence imaging versus histopathology
Временное ограничение: From surgery to final histopathology (up to ~2 weeks after surgery)
Sensitivity, specificity, positive and negative predictive value, and area under the ROC curve for goggle-based near-infrared fluorescence detection of tumor-positive lymph nodes, using final histopathology as the reference standard, with confidence intervals accounting for clustering of nodes within patients.
From surgery to final histopathology (up to ~2 weeks after surgery)

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Patient-level sentinel-node detection rate
Временное ограничение: Final histopathology (up to approximately 2 weeks after surgery)
Proportion of patients in whom at least one sentinel lymph node is identified by AR-ICG near-infrared fluorescence imaging.
Final histopathology (up to approximately 2 weeks after surgery)
Concordance of device-marked nodes with histopathology
Временное ограничение: Final histopathology (up to approximately 2 weeks after surgery)
Agreement between lymph nodes marked by AR-ICG fluorescence imaging and nodal status confirmed on final histopathology.
Final histopathology (up to approximately 2 weeks after surgery)
Per-device diagnostic performance across near-infrared imaging systems
Временное ограничение: Through study completion (up to approximately 24 months)
Sensitivity, specificity, positive predictive value, negative predictive value, and area under the ROC curve estimated separately for each near-infrared imaging device evaluated, using final histopathology as the reference standard, on consecutive eligible patients within defined enrollment windows.
Through study completion (up to approximately 24 months)
False-negative rate of AR-ICG fluorescence node detection
Временное ограничение: Final histopathology (up to approximately 2 weeks after surgery)
Proportion of pathology-confirmed tumor-positive lymph nodes not identified as fluorescent by AR-ICG imaging.
Final histopathology (up to approximately 2 weeks after surgery)
Number of candidate sentinel nodes identified per patient
Временное ограничение: Intraoperative (day of surgery)
Number of candidate sentinel lymph nodes marked by AR-ICG fluorescence imaging per patient (count).
Intraoperative (day of surgery)

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Публикации и полезные ссылки

Лицо, ответственное за внесение сведений об исследовании, добровольно предоставляет эти публикации. Это может быть что угодно, связанное с исследованием.

Общие публикации

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Оцененный)

1 июля 2026 г.

Первичное завершение (Оцененный)

1 июля 2028 г.

Завершение исследования (Оцененный)

31 декабря 2028 г.

Даты регистрации исследования

Первый отправленный

28 июня 2026 г.

Впервые представлено, что соответствует критериям контроля качества

28 июня 2026 г.

Первый опубликованный (Действительный)

6 июля 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

6 июля 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

28 июня 2026 г.

Последняя проверка

1 июня 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕТ

Описание плана IPD

This is a single-center observational device-validation study. Individual participant data are not planned to be shared. De-identified data may be made available from the principal investigator on reasonable request, subject to institutional approval.

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться