This study evaluates how accurately augmented-reality goggles with indocyanine green (ICG) near-infrared fluorescence can identify sentinel (first-draining) lymph nodes during breast cancer surgery. The goggles and ICG signal are used to mark candidate sentinel nodes, and an additional observer may record near-infrared images during the operation for device-performance assessment. These imaging findings do not change the surgical procedure. The candidate nodes and all removed tissue are examined by histopathology, which serves as the reference standard. Two hundred patients undergoing breast cancer surgery will take part. The study measures how well the goggle-based imaging detects nodes that contain cancer, compared with final pathology.

Panoramica dello studio

Descrizione dettagliata

This is a prospective observational device-validation study in patients undergoing breast cancer surgery with axillary evaluation. Augmented-reality goggle-based near-infrared fluorescence imaging with ICG is used to visualize and mark candidate sentinel lymph nodes. Intraoperative near-infrared imaging may be performed by an observer who is not the operating surgeon, solely to assess device performance; observer findings are not communicated to the operating surgeon before wound closure and do not influence the operation. All marked nodes and removed tissue undergo histopathology, which serves as the blinded reference standard. Device performance is assessed on consecutive eligible patients within defined enrollment windows; for each near-infrared imaging device, sensitivity, specificity, positive and negative predictive value, and node-level ROC analysis are estimated against final histopathology, with confidence intervals accounting for clustering of nodes within patients. The study is non-interventional: the imaging does not alter surgical management.

Tipo di studio

Osservativo

Iscrizione (Stimato)

200

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

No

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Patients with histologically proven breast cancer undergoing surgery with axillary lymph node evaluation at the participating center, enrolled consecutively.

Descrizione

Inclusion Criteria:

  • Histologically proven breast cancer
  • Age 18 years or older
  • Undergoing breast cancer surgery with sentinel lymph node evaluation and/or axillary lymph node dissection
  • Provides written informed consent

Exclusion Criteria:

  • Pregnancy
  • Neoadjuvant chemotherapy
  • Prior breast surgery
  • Iodine or seafood allergy
  • Indocyanine green (ICG) allergy
  • Declines or is unable to provide informed consent

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
Breast cancer patients undergoing surgery with AR-ICG node imaging
Patients undergoing breast cancer surgery in whom AR-ICG goggle-based near-infrared imaging is used to mark candidate sentinel nodes, with optional observer near-infrared imaging for device-performance assessment; histopathology is the reference standard.
Augmented-reality goggle-based near-infrared fluorescence imaging with indocyanine green (ICG), used to visualize and mark candidate sentinel lymph nodes during breast cancer surgery. Intraoperative near-infrared imaging may also be recorded by an observer for device-performance assessment. Imaging does not alter surgical management; histopathology serves as the reference standard.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Node-level diagnostic accuracy of AR-ICG fluorescence imaging versus histopathology
Lasso di tempo: From surgery to final histopathology (up to ~2 weeks after surgery)
Sensitivity, specificity, positive and negative predictive value, and area under the ROC curve for goggle-based near-infrared fluorescence detection of tumor-positive lymph nodes, using final histopathology as the reference standard, with confidence intervals accounting for clustering of nodes within patients.
From surgery to final histopathology (up to ~2 weeks after surgery)

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Patient-level sentinel-node detection rate
Lasso di tempo: Final histopathology (up to approximately 2 weeks after surgery)
Proportion of patients in whom at least one sentinel lymph node is identified by AR-ICG near-infrared fluorescence imaging.
Final histopathology (up to approximately 2 weeks after surgery)
Concordance of device-marked nodes with histopathology
Lasso di tempo: Final histopathology (up to approximately 2 weeks after surgery)
Agreement between lymph nodes marked by AR-ICG fluorescence imaging and nodal status confirmed on final histopathology.
Final histopathology (up to approximately 2 weeks after surgery)
Per-device diagnostic performance across near-infrared imaging systems
Lasso di tempo: Through study completion (up to approximately 24 months)
Sensitivity, specificity, positive predictive value, negative predictive value, and area under the ROC curve estimated separately for each near-infrared imaging device evaluated, using final histopathology as the reference standard, on consecutive eligible patients within defined enrollment windows.
Through study completion (up to approximately 24 months)
False-negative rate of AR-ICG fluorescence node detection
Lasso di tempo: Final histopathology (up to approximately 2 weeks after surgery)
Proportion of pathology-confirmed tumor-positive lymph nodes not identified as fluorescent by AR-ICG imaging.
Final histopathology (up to approximately 2 weeks after surgery)
Number of candidate sentinel nodes identified per patient
Lasso di tempo: Intraoperative (day of surgery)
Number of candidate sentinel lymph nodes marked by AR-ICG fluorescence imaging per patient (count).
Intraoperative (day of surgery)

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Pubblicazioni generali

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 luglio 2026

Completamento primario (Stimato)

1 luglio 2028

Completamento dello studio (Stimato)

31 dicembre 2028

Date di iscrizione allo studio

Primo inviato

28 giugno 2026

Primo inviato che soddisfa i criteri di controllo qualità

28 giugno 2026

Primo Inserito (Effettivo)

6 luglio 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

6 luglio 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

28 giugno 2026

Ultimo verificato

1 giugno 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Descrizione del piano IPD

This is a single-center observational device-validation study. Individual participant data are not planned to be shared. De-identified data may be made available from the principal investigator on reasonable request, subject to institutional approval.

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Cancro al seno

3
Sottoscrivi