Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Shear Wave Ultrasound Elastography in Noninvasive Diagnosis of Thyroid Nodules

26 maggio 2015 aggiornato da: Manjiri Dighe, University of Washington

Efficacy of Shear Wave Ultrasound Elastography in Noninvasive Diagnosis of Thyroid Nodules

Shear wave ultrasound elastography is a new technique of finding the softness or hardness in tissue by applying a "push" generated by the machine. This technique will help in diagnosing malignancy in the thyroid gland without biopsy and avoiding biopsy in noncancerous nodules.

Panoramica dello studio

Stato

Sconosciuto

Condizioni

Intervento / Trattamento

Descrizione dettagliata

Thyroid nodules are a common medical problem. With the wide use of various imaging modalities, incidentally detected thyroid nodules are becoming more common. However most of these nodules are benign with only a small proportion of 5-10% being malignant. With the increasing number of nodules detected, evaluation of these thyroid nodules presents a diagnostic challenge since the imaging modality used for evaluation at present, i.e., ultrasound (US) alone, has a low specificity of approximately 50-70%. In order to improve specificity to confidently diagnose malignancy in the thyroid nodule, a fine needle aspiration (FNA) biopsy is performed.

In recent years, US elastography has been shown to have high specificity of 90- 98% in various studies in differentiating between benign and malignant nodules. US elastography works on the principle of detecting the stiffness within a tissue by applying compression which can be manual compression or by generation of a remote radiation force by focused ultrasonic beams called as shear waves. Shear Wave Ultrasound (SWUS) elastography is an objective method of US elastography that detects the stiffness within the nodule since the strength of the shear wave generated is known and can be controlled. SWUS elastography has shown promise in being able to noninvasively diagnose papillary carcinoma in previous studies involving preoperative patients.

The investigators propose to perform a study to investigate the efficacy of SWUS elastography in diagnosing malignant thyroid nodules and noninvasively decreasing the number of FNAs performed by avoiding FNA in benign nodules. The Investigators will enroll patients with thyroid nodules before they undergo FNA biopsy or surgery. We also propose to compare routine US and SWUS elastography and their combined use in differentiating malignant from benign nodules. The investigators hypothesize that SWUS elastography can be used as a noninvasive screening tool, prior to an FNA, to screen out benign and malignant nodules with high level of confidence and reduce the number of biopsies in the future.

Tipo di studio

Interventistico

Iscrizione (Anticipato)

175

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Washington
      • Seattle, Washington, Stati Uniti, 98195
        • University of Washington Medical Center

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Clinical diagnosis of thyroid nodule
  • Referred for thyroid FNA or surgery

Exclusion Criteria:

  • Minors; age <18
  • Unable to provide informed consent

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Diagnostico
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: SWUS Elastography
This is a noninvasive technique using focused ultrasonic beams (pushing beams.) Several pushing beams at increasing depths are transmitted to generate a quasi-plane shear wave frame that propagates throughout the imaging area. After generating the shear wave, an ultrafast imaging sequence is performed to acquire successive raw radiofrequency dots at a very high frame rate (up to 20,000 per second). A tissue elasticity assessment can be derived from shear wave propagation speed. A color-coded image is displayed; softer tissue in blue and stiffer tissue in red. Quantitative information is delivered by drawing regions of interest on the thyroid and surrounding tissues which is the Elasticity Index expressed in kilo-Pascal (kPa). Due to the lack of manual compression and known value of the strength of pushing beam, SWUS gives an objective number to stiffness within the nodule.
Altri nomi:
  • Aixplorer Ultrasound System (SuperSonic Imagine, Inc)

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Correlating stiffness from the SWUS elastography with indentometer and pathology findings
Lasso di tempo: Up to 2 months. A one-time SWUS elastography will be performed on Day 1 within 2 months prior to the patients scheduled clinical FNA or surgery.

SWUS elastography can provide an objective score of stiffness, i.e., the Elasticity Index.

Stiffness from the SWUS elastography will be correlated with the elasticity measured with an indentometer to validate the Elasticity Index. The Elasticity Index will also be correlated with the histopathologic diagnosis. The sensitivity and specificity of the method for the diagnosis of malignancy will be assessed.

Up to 2 months. A one-time SWUS elastography will be performed on Day 1 within 2 months prior to the patients scheduled clinical FNA or surgery.

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Correlating SWUS findings with routine US findings
Lasso di tempo: Up to 2 months. A one-time SWUS elastography will be performed on Day 1 within 2 months prior to the patients scheduled clinical FNA or surgery.
The investigators will compare the SWUS findings to the routine US findings. This will help us develop criteria based on combined findings to decide if a thyroid nodule is suspicious enough to warrant a FNA biopsy. These criteria can then be used for future prospective studies.
Up to 2 months. A one-time SWUS elastography will be performed on Day 1 within 2 months prior to the patients scheduled clinical FNA or surgery.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Manjiri K. Dighe, MD, University of Washington

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Pubblicazioni generali

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

1 novembre 2012

Completamento primario (Anticipato)

1 luglio 2015

Completamento dello studio (Anticipato)

1 agosto 2015

Date di iscrizione allo studio

Primo inviato

12 dicembre 2012

Primo inviato che soddisfa i criteri di controllo qualità

21 dicembre 2012

Primo Inserito (Stima)

31 dicembre 2012

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Stima)

28 maggio 2015

Ultimo aggiornamento inviato che soddisfa i criteri QC

26 maggio 2015

Ultimo verificato

1 maggio 2015

Maggiori informazioni

Termini relativi a questo studio

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su SWUS Elastography

3
Sottoscrivi