経カテーテル大動脈弁移植後に新たに発症した持続性左脚ブロックを有する患者における高度房室ブロックの検出のための外来心電図モニタリング。 「MARE」研究 (MARE)
The purpose of this study is to determine the incidence and predictors of high degree or complete atrioventricular block (AVB) (paroxysmal or persistent) in patients with new-onset persistent left bundle branch block (NOP-LBBB) following transcatheter aortic valve implantation (TAVI) and to evaluate the usefulness of the Reveal LINQ® insertable Cardiac Monitor (ICM) (Medtronic, Inc., Minneapolis, USA) for the detection of significant arrhythmias in patients with NOP-LBBB following TAVI.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
This is a prospective observational study including patients undergoing TAVI with either self- or balloon-expandable valves. After the procedure, patients will be on ECG monitoring during the hospitalization period (or at least 72 hours), and an ECG will be performed daily until hospital discharge in all patients. Patients with new-onset persistent LBBB at hospital discharge (new-onset LBBB of a duration of at least 48 h which persists at hospital discharge, at least 3 days and up to 15 days after the procedure) will receive an implantable loop recorder Reveal ICM LINQ®, which will be implanted subcutaneously to record adequate QRS complexes and P waves. The patients will be followed in outpatient clinic visits at 1, 12, 24 and 36 months after TAVR, or if symptoms suggestive of cardiac origin or relevant arrhythmic events occur. The device will be manually interrogated in each visit. Phone contacts will be also carried out every three months.
研究の種類
研究の種類
入学 (推定)
入学
段階
段階
- 適用できない
連絡先と場所
研究場所
-
-
Quebec
-
Québec、Quebec、カナダ、G1V 4G5
- 募集
- IUCPQ
-
コンタクト:
- Emilie Pelletier Beaumont, M.Sc.
- 電話番号:3929 418-656-8711
- メール:Emilie.Pelletier-Beaumont@criucpq.ulaval.ca
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
-Patients undergoing TAVI with either balloon or self-expandable valves who develop new-onset LBBB persistent at hospital discharge, at least 3 days after the procedure
Exclusion Criteria:
- Failure to provide informed consent
- Baseline pacemaker/defibrillator or pacemaker/defibrillator implanted during the hospitalization period following the TAVI procedure
- Pre-existing complete LBBB
- Patients with a life-expectancy of less than 2 years
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:埋め込み型ループ レコーダーは、ICM LINQ® を明らかにします。
|
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
-高度または完全なAVBの発症率と時期
時間枠:1年
|
1年
|
|
-治療の変更または主要な有害事象につながるIRLによって特定された不整脈イベントの発生率
時間枠:1年
|
1年
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
-AVBの高度または完全な割合
時間枠:TAVI施術後1ヶ月以内
|
TAVI施術後1ヶ月以内
|
|
|
-AVBの高度または完全な割合
時間枠:6ヶ月のフォローアップ
|
6ヶ月のフォローアップ
|
|
|
-高度または完全なAVBの割合
時間枠:24か月のフォローアップ
|
24か月のフォローアップ
|
|
|
-高度または完全なAVBの割合
時間枠:36ヶ月のフォローアップ
|
36ヶ月のフォローアップ
|
|
|
-新たな心房細動または心室性不整脈の発生率
時間枠:TAVI処置後の最初の3年以内
|
TAVI処置後の最初の3年以内
|
|
|
-経時的な左心室機能と僧帽弁逆流の変化
時間枠:TAVI処置後の最初の3年以内
|
TAVI処置後の最初の3年以内
|
|
|
-Electrocardiographic and device-related factors predicting the occurence of high degree or complete AVB in patients with new-onset LBBB after TAVI
時間枠:Within the first 3 years following TAVI procedure
|
Periprocedural results of TAVI of patients with NOP-LVV will be used to characterize predictors of high degree or complete AVB. Moreover, electrocardiographic characteristics at hospital discharge of patients with NOP-LVV will also be used to characterize predictors of high degree or complete AVB. |
Within the first 3 years following TAVI procedure
|
協力者と研究者
スポンサー
スポンサー
捜査官
捜査官
- 主任研究者:Josep Rodes, MD、Fondation IUCPQ
出版物と役立つリンク
一般刊行物
- Krahn AD, Klein GJ, Yee R, Takle-Newhouse T, Norris C. Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators. Circulation. 1999 Jan 26;99(3):406-10. doi: 10.1161/01.cir.99.3.406.
- Lombardi F, Calosso E, Mascioli G, Marangoni E, Donato A, Rossi S, Pala M, Foti F, Lunati M. Utility of implantable loop recorder (Reveal Plus) in the diagnosis of unexplained syncope. Europace. 2005 Jan;7(1):19-24. doi: 10.1016/j.eupc.2004.09.003.
- Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA 3rd, Freedman RA, Gettes LS, Gillinov AM, Gregoratos G, Hammill SC, Hayes DL, Hlatky MA, Newby LK, Page RL, Schoenfeld MH, Silka MJ, Stevenson LW, Sweeney MO; American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines; Heart Rhythm Society. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. Circulation. 2013 Jan 22;127(3):e283-352. doi: 10.1161/CIR.0b013e318276ce9b. Epub 2012 Dec 19. No abstract available.
- Surawicz B, Childers R, Deal BJ, Gettes LS, Bailey JJ, Gorgels A, Hancock EW, Josephson M, Kligfield P, Kors JA, Macfarlane P, Mason JW, Mirvis DM, Okin P, Pahlm O, Rautaharju PM, van Herpen G, Wagner GS, Wellens H; American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; American College of Cardiology Foundation; Heart Rhythm Society. AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society. Endorsed by the International Society for Computerized Electrocardiology. J Am Coll Cardiol. 2009 Mar 17;53(11):976-81. doi: 10.1016/j.jacc.2008.12.013. No abstract available.
- Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodes-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB; Valve Academic Research Consortium (VARC)-2. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg. 2012 Nov;42(5):S45-60. doi: 10.1093/ejcts/ezs533. Epub 2012 Oct 1.
- Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, Krucoff MW, Mack M, Mehran R, Miller C, Morel MA, Petersen J, Popma JJ, Takkenberg JJ, Vahanian A, van Es GA, Vranckx P, Webb JG, Windecker S, Serruys PW. Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium. J Am Coll Cardiol. 2011 Jan 18;57(3):253-69. doi: 10.1016/j.jacc.2010.12.005. Epub 2011 Jan 7.
- Thompson R, Mitchell A, Ahmed M, Towers M, Yacoub M. Conduction defects in aortic valve disease. Am Heart J. 1979 Jul;98(1):3-10. doi: 10.1016/0002-8703(79)90313-2. No abstract available.
- El-Khally Z, Thibault B, Staniloae C, Theroux P, Dubuc M, Roy D, Guerra P, Macle L, Talajic M. Prognostic significance of newly acquired bundle branch block after aortic valve replacement. Am J Cardiol. 2004 Oct 15;94(8):1008-11. doi: 10.1016/j.amjcard.2004.06.055.
- Thomas JL, Dickstein RA, Parker FB Jr, Potts JL, Poirier RA, Fruehan CT, Eich RH. Prognostic significance of the development of left bundle conduction defects following aortic valve replacement. J Thorac Cardiovasc Surg. 1982 Sep;84(3):382-6.
- Foppl M, Hoffmann A, Amann FW, Roth J, Stulz P, Hasse J, Gradel E, Burckhardt D. Sudden cardiac death after aortic valve surgery: incidence and concomitant factors. Clin Cardiol. 1989 Apr;12(4):202-7. doi: 10.1002/clc.4960120405.
- van der Boon RM, Nuis RJ, Van Mieghem NM, Jordaens L, Rodes-Cabau J, van Domburg RT, Serruys PW, Anderson RH, de Jaegere PP. New conduction abnormalities after TAVI--frequency and causes. Nat Rev Cardiol. 2012 May 1;9(8):454-63. doi: 10.1038/nrcardio.2012.58.
- Dou J, Xia L, Zhang Y, Shou G, Wei Q, Liu F, Crozier S. Mechanical analysis of congestive heart failure caused by bundle branch block based on an electromechanical canine heart model. Phys Med Biol. 2009 Jan 21;54(2):353-71. doi: 10.1088/0031-9155/54/2/012. Epub 2008 Dec 19.
- Piazza N, Nuis RJ, Tzikas A, Otten A, Onuma Y, Garcia-Garcia H, Schultz C, van Domburg R, van Es GA, van Geuns R, de Jaegere P, Serruys PW. Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation. EuroIntervention. 2010 Sep;6(4):475-84. doi: 10.4244/EIJ30V6I4A80.
- Houthuizen P, Van Garsse LA, Poels TT, de Jaegere P, van der Boon RM, Swinkels BM, Ten Berg JM, van der Kley F, Schalij MJ, Baan J Jr, Cocchieri R, Brueren GR, van Straten AH, den Heijer P, Bentala M, van Ommen V, Kluin J, Stella PR, Prins MH, Maessen JG, Prinzen FW. Left bundle-branch block induced by transcatheter aortic valve implantation increases risk of death. Circulation. 2012 Aug 7;126(6):720-8. doi: 10.1161/CIRCULATIONAHA.112.101055. Epub 2012 Jul 12.
- Testa L, Latib A, De Marco F, De Carlo M, Agnifili M, Latini RA, Petronio AS, Ettori F, Poli A, De Servi S, Ramondo A, Napodano M, Klugmann S, Ussia GP, Tamburino C, Brambilla N, Colombo A, Bedogni F. Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System. Circulation. 2013 Mar 26;127(12):1300-7. doi: 10.1161/CIRCULATIONAHA.112.001099. Epub 2013 Feb 26.
- Urena M, Mok M, Serra V, Dumont E, Nombela-Franco L, DeLarochelliere R, Doyle D, Igual A, Larose E, Amat-Santos I, Cote M, Cuellar H, Pibarot P, de Jaegere P, Philippon F, Garcia del Blanco B, Rodes-Cabau J. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve. J Am Coll Cardiol. 2012 Oct 30;60(18):1743-52. doi: 10.1016/j.jacc.2012.07.035. Epub 2012 Oct 3.
- Moya A, Garcia-Civera R, Croci F, Menozzi C, Brugada J, Ammirati F, Del Rosso A, Bellver-Navarro A, Garcia-Sacristan J, Bortnik M, Mont L, Ruiz-Granell R, Navarro X; Bradycardia detection in Bundle Branch Block (B4) study. Diagnosis, management, and outcomes of patients with syncope and bundle branch block. Eur Heart J. 2011 Jun;32(12):1535-41. doi: 10.1093/eurheartj/ehr071. Epub 2011 Mar 28.
- Furukawa T, Maggi R, Bertolone C, Fontana D, Brignole M. Additional diagnostic value of very prolonged observation by implantable loop recorder in patients with unexplained syncope. J Cardiovasc Electrophysiol. 2012 Jan;23(1):67-71. doi: 10.1111/j.1540-8167.2011.02133.x. Epub 2011 Jul 21.
- Paruchuri V, Adhaduk M, Garikipati NV, Steinberg JS, Mittal S. Clinical utility of a novel wireless implantable loop recorder in the evaluation of patients with unexplained syncope. Heart Rhythm. 2011 Jun;8(6):858-63. doi: 10.1016/j.hrthm.2011.01.039. Epub 2011 Feb 2.
- Krahn AD, Klein GJ, Yee R, Hoch JS, Skanes AC. Cost implications of testing strategy in patients with syncope: randomized assessment of syncope trial. J Am Coll Cardiol. 2003 Aug 6;42(3):495-501. doi: 10.1016/s0735-1097(03)00659-4.
- Crossley GH, Boyle A, Vitense H, Chang Y, Mead RH; CONNECT Investigators. The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: the value of wireless remote monitoring with automatic clinician alerts. J Am Coll Cardiol. 2011 Mar 8;57(10):1181-9. doi: 10.1016/j.jacc.2010.12.012. Epub 2011 Jan 20.
- Goldberger JJ, Cain ME, Hohnloser SH, Kadish AH, Knight BP, Lauer MS, Maron BJ, Page RL, Passman RS, Siscovick D, Siscovick D, Stevenson WG, Zipes DP; American Heart Association; American College of Cardiology Foundation; Heart Rhythm Society. American Heart Association/American College of Cardiology Foundation/Heart Rhythm Society scientific statement on noninvasive risk stratification techniques for identifying patients at risk for sudden cardiac death: a scientific statement from the American Heart Association Council on Clinical Cardiology Committee on Electrocardiography and Arrhythmias and Council on Epidemiology and Prevention. Circulation. 2008 Sep 30;118(14):1497-1518. No abstract available.
- Muntane-Carol G, Urena M, Nombela-Franco L, Amat-Santos I, Kleiman N, Munoz-Garcia A, Atienza F, Serra V, Deyell MW, Veiga-Fernandez G, Masson JB, Canadas-Godoy V, Himbert D, Castrodeza J, Elizaga J, Francisco Pascual J, Webb JG, de la Torre Hernandez JM, Asmarats L, Pelletier-Beaumont E, Philippon F, Rodes-Cabau J. Arrhythmic burden in patients with new-onset persistent left bundle branch block after transcatheter aortic valve replacement: 2-year results of the MARE study. Europace. 2021 Feb 5;23(2):254-263. doi: 10.1093/europace/euaa213.
- Rodes-Cabau J, Urena M, Nombela-Franco L, Amat-Santos I, Kleiman N, Munoz-Garcia A, Atienza F, Serra V, Deyell MW, Veiga-Fernandez G, Masson JB, Canadas-Godoy V, Himbert D, Castrodeza J, Elizaga J, Francisco Pascual J, Webb JG, de la Torre JM, Asmarats L, Pelletier-Beaumont E, Philippon F. Arrhythmic Burden as Determined by Ambulatory Continuous Cardiac Monitoring in Patients With New-Onset Persistent Left Bundle Branch Block Following Transcatheter Aortic Valve Replacement: The MARE Study. JACC Cardiovasc Interv. 2018 Aug 13;11(15):1495-1505. doi: 10.1016/j.jcin.2018.04.016. Epub 2018 Jul 18.
- Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH. Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv. 2008 Aug;1(1):74-81. doi: 10.1161/CIRCINTERVENTIONS.108.780858.
- Task Force members; Brignole M, Vardas P, Hoffman E, Huikuri H, Moya A, Ricci R, Sulke N, Wieling W; EHRA Scientific Documents Committee; Auricchio A, Lip GY, Almendral J, Kirchhof P, Aliot E, Gasparini M, Braunschweig F; Document Reviewers; Lip GY, Almendral J, Kirchhof P, Botto GL; EHRA Scientific Documents Committee. Indications for the use of diagnostic implantable and external ECG loop recorders. Europace. 2009 May;11(5):671-87. doi: 10.1093/europace/eup097. No abstract available.
研究記録日
主要日程の研究
研究開始
研究開始
一次修了 (実際)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (推定)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。