このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

The Use of Two Different Smartphone Applications in Measuring

2026年9月21日 更新者:Esra BAYRAMOĞLU DEMİRDÖĞEN、Ahi Evran University Education and Research Hospital

An Investigation of the Intra- and Inter-Rater Reliability of Two Different Smartphone Applications Used in the Measurement of Sagittal Spinal Curvature

This study will include healthy volunteers aged 18-25 years. Demographic information will be recorded, and an experienced physiotherapist will mark five reference points on the spine of the participants, starting from the cervical spine and extending to the lumbar spine. Angle measurements will then be taken from these five reference points using a gravity inclinometer, an Android smartphone, and an iOS phone. Measurements will be repeated twice on the same day and twice again 24-48 hours later using three different devices. The accuracy and similarity of the measurements taken with these three devices will then be compared.

調査の概要

状態

完了

条件

詳細な説明

This study is designed as an observational, methodological study to investigate the intra-rater and inter-rater reliability and concurrent validity of two smartphone-based inclinometer applications used for sagittal spinal curvature assessment.

The study will include healthy volunteers aged 18-25 years. Participants will be informed about the study procedures, and written informed consent will be obtained before enrollment. Demographic and anthropometric characteristics, including age, sex, height, body weight, and body mass index, will be recorded.

Measurement Procedures An experienced physiotherapist will identify and mark five anatomical reference points along the spine, extending from the cervical region to the lumbosacral region. These reference points will be used to standardize the measurement locations across devices and assessment sessions.

Sagittal spinal inclination angles will be measured using three different devices:

A conventional gravity-based bubble inclinometer. An Android smartphone equipped with an inclinometer application. An iOS smartphone equipped with an inclinometer application. Measurements will be performed at the same anatomical reference points using all three devices. The conventional inclinometer will serve as a reference instrument for evaluating the concurrent validity of the smartphone applications.

Reliability Assessment To evaluate intra-rater and inter-rater reliability, measurements will be performed by three assessors using a standardized assessment protocol.

Each measurement will be repeated twice during the initial assessment session. A second assessment session will be conducted 24-48 hours after the first session, during which the measurements will be repeated using the same three devices.

The repeated measurements will allow the evaluation of within-assessor consistency, agreement between different assessors, and measurement stability across assessment sessions.

Concurrent Validity Assessment The measurements obtained from the Android and iOS smartphone applications will be compared with those obtained using the conventional bubble inclinometer.

The agreement between the smartphone applications and the conventional inclinometer will be examined to determine whether smartphone-based measurements provide comparable results for sagittal spinal inclination assessment.

Statistical Analysis Descriptive statistics will be used to summarize participant characteristics and measurement results.

Intraclass correlation coefficients (ICCs) will be calculated to evaluate intra-rater reliability, inter-rater reliability, and test-retest reliability. Measurement error will be examined using the standard error of measurement (SEM) and minimal detectable change (MDC).

Concurrent validity will be assessed through correlation and agreement analyses. Pearson correlation coefficients, Lin's concordance correlation coefficients, and Bland-Altman analyses will be used to investigate the relationships, concordance, and systematic differences between measurements obtained using the smartphone applications and the conventional inclinometer.

Expected Contribution The study aims to provide evidence regarding the reliability and concurrent validity of smartphone-based inclinometer applications for assessing sagittal spinal inclination. The findings may help determine the potential clinical applicability of smartphone-based measurement tools in physiotherapy and rehabilitation assessments.

研究の種類

観察的

入学 (実際)

63

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年~25年 (大人)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

healthy older individuals

説明

Inclusion Criteria:

  • Being over 18 years of age,
  • being able to stand and walk without an assistive device,
  • not having experienced back pain or lower extremity pain in the last 6 months,
  • and being willing to participate in the study.

Exclusion Criteria:

  • Lack of consent,
  • lower extremity injuries (dislocation, sprain) within one month prior to measurement,
  • lower extremity fractures within the last 6 months,
  • tactile sensitivity that prevents the adoption of a free and habitual posture.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 観測モデル:COHORT
  • 時間の展望:CROSS_SECTIONAL

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Assessment of Spinal Curvature
時間枠:Two measurements taken 10 minutes apart.

Description: The following 5 parameters were used for the measurement: 1. ALPHA 1 angle of sacrum (upper beam of the inclinometer, in the middle of the intervertebral space, on the line connecting the posterior superior iliac crests). 2. ALPHA 2 angle - sacrolumbar junction S/L (center of the inclinometer on the line connecting the posterior superior iliac crests). 3. BETA angle - Th12-L1 thoracolumbar junction (center of the inclinometer at the thoracolumbar junction). 4. GAMMA angle - C7-Th1 (center of the inclinometer on C7). 5. DELTA angle - Th3-Th4 (upper beam of the inclinometer at the height of the upper angle of the scapula).

Two measurements taken 10 minutes apart.

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Esra BAYRAMOĞLU DEMİRDÖĞEN、Kırşehir Eğitim ve Araştırma Hastanesi

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年3月14日

一次修了 (実際)

2026年4月15日

研究の完了 (実際)

2026年4月30日

試験登録日

最初に提出

2026年3月30日

QC基準を満たした最初の提出物

2026年3月30日

最初の投稿 (実際)

2026年4月3日

学習記録の更新

投稿された最後の更新 (実際)

2026年9月24日

QC基準を満たした最後の更新が送信されました

2026年9月21日

最終確認日

2026年9月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • KAEU-EBAYRAMOGLUD-006

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。