이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

The Use of Two Different Smartphone Applications in Measuring

2026년 9월 21일 업데이트: Esra BAYRAMOĞLU DEMİRDÖĞEN, Ahi Evran University Education and Research Hospital

An Investigation of the Intra- and Inter-Rater Reliability of Two Different Smartphone Applications Used in the Measurement of Sagittal Spinal Curvature

This study will include healthy volunteers aged 18-25 years. Demographic information will be recorded, and an experienced physiotherapist will mark five reference points on the spine of the participants, starting from the cervical spine and extending to the lumbar spine. Angle measurements will then be taken from these five reference points using a gravity inclinometer, an Android smartphone, and an iOS phone. Measurements will be repeated twice on the same day and twice again 24-48 hours later using three different devices. The accuracy and similarity of the measurements taken with these three devices will then be compared.

연구 개요

상태

완전한

정황

상세 설명

This study is designed as an observational, methodological study to investigate the intra-rater and inter-rater reliability and concurrent validity of two smartphone-based inclinometer applications used for sagittal spinal curvature assessment.

The study will include healthy volunteers aged 18-25 years. Participants will be informed about the study procedures, and written informed consent will be obtained before enrollment. Demographic and anthropometric characteristics, including age, sex, height, body weight, and body mass index, will be recorded.

Measurement Procedures An experienced physiotherapist will identify and mark five anatomical reference points along the spine, extending from the cervical region to the lumbosacral region. These reference points will be used to standardize the measurement locations across devices and assessment sessions.

Sagittal spinal inclination angles will be measured using three different devices:

A conventional gravity-based bubble inclinometer. An Android smartphone equipped with an inclinometer application. An iOS smartphone equipped with an inclinometer application. Measurements will be performed at the same anatomical reference points using all three devices. The conventional inclinometer will serve as a reference instrument for evaluating the concurrent validity of the smartphone applications.

Reliability Assessment To evaluate intra-rater and inter-rater reliability, measurements will be performed by three assessors using a standardized assessment protocol.

Each measurement will be repeated twice during the initial assessment session. A second assessment session will be conducted 24-48 hours after the first session, during which the measurements will be repeated using the same three devices.

The repeated measurements will allow the evaluation of within-assessor consistency, agreement between different assessors, and measurement stability across assessment sessions.

Concurrent Validity Assessment The measurements obtained from the Android and iOS smartphone applications will be compared with those obtained using the conventional bubble inclinometer.

The agreement between the smartphone applications and the conventional inclinometer will be examined to determine whether smartphone-based measurements provide comparable results for sagittal spinal inclination assessment.

Statistical Analysis Descriptive statistics will be used to summarize participant characteristics and measurement results.

Intraclass correlation coefficients (ICCs) will be calculated to evaluate intra-rater reliability, inter-rater reliability, and test-retest reliability. Measurement error will be examined using the standard error of measurement (SEM) and minimal detectable change (MDC).

Concurrent validity will be assessed through correlation and agreement analyses. Pearson correlation coefficients, Lin's concordance correlation coefficients, and Bland-Altman analyses will be used to investigate the relationships, concordance, and systematic differences between measurements obtained using the smartphone applications and the conventional inclinometer.

Expected Contribution The study aims to provide evidence regarding the reliability and concurrent validity of smartphone-based inclinometer applications for assessing sagittal spinal inclination. The findings may help determine the potential clinical applicability of smartphone-based measurement tools in physiotherapy and rehabilitation assessments.

연구 유형

관찰

등록 (실제)

63

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

      • Kırşehir, 터키 (Türkiye), 40100
        • Kırşehir Ahi Evran Üniversitesi

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 (성인)

건강한 자원 봉사자를 받아들입니다

예

연구 대상 성별

모두

샘플링 방법

비확률 샘플

연구 인구

healthy older individuals

설명

Inclusion Criteria:

  • Being over 18 years of age,
  • being able to stand and walk without an assistive device,
  • not having experienced back pain or lower extremity pain in the last 6 months,
  • and being willing to participate in the study.

Exclusion Criteria:

  • Lack of consent,
  • lower extremity injuries (dislocation, sprain) within one month prior to measurement,
  • lower extremity fractures within the last 6 months,
  • tactile sensitivity that prevents the adoption of a free and habitual posture.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 관찰 모델: COHORT
  • 시간 관점: CROSS_SECTIONAL

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Assessment of Spinal Curvature
기간: Two measurements taken 10 minutes apart.

Description: The following 5 parameters were used for the measurement: 1. ALPHA 1 angle of sacrum (upper beam of the inclinometer, in the middle of the intervertebral space, on the line connecting the posterior superior iliac crests). 2. ALPHA 2 angle - sacrolumbar junction S/L (center of the inclinometer on the line connecting the posterior superior iliac crests). 3. BETA angle - Th12-L1 thoracolumbar junction (center of the inclinometer at the thoracolumbar junction). 4. GAMMA angle - C7-Th1 (center of the inclinometer on C7). 5. DELTA angle - Th3-Th4 (upper beam of the inclinometer at the height of the upper angle of the scapula).

Two measurements taken 10 minutes apart.

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

수사관

  • 수석 연구원: Esra BAYRAMOĞLU DEMİRDÖĞEN, Kırşehir Eğitim ve Araştırma Hastanesi

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 3월 14일

기본 완료 (실제)

2026년 4월 15일

연구 완료 (실제)

2026년 4월 30일

연구 등록 날짜

최초 제출

2026년 3월 30일

QC 기준을 충족하는 최초 제출

2026년 3월 30일

처음 게시됨 (실제)

2026년 4월 3일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 9월 24일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 9월 21일

마지막으로 확인됨

2026년 9월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • KAEU-EBAYRAMOGLUD-006

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .