The Use of Two Different Smartphone Applications in Measuring
An Investigation of the Intra- and Inter-Rater Reliability of Two Different Smartphone Applications Used in the Measurement of Sagittal Spinal Curvature
This study will include healthy volunteers aged 18-25 years. Demographic information will be recorded, and an experienced physiotherapist will mark five reference points on the spine of the participants, starting from the cervical spine and extending to the lumbar spine. Angle measurements will then be taken from these five reference points using a gravity inclinometer, an Android smartphone, and an iOS phone. Measurements will be repeated twice on the same day and twice again 24-48 hours later using three different devices. The accuracy and similarity of the measurements taken with these three devices will then be compared.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Detailní popis
This study is designed as an observational, methodological study to investigate the intra-rater and inter-rater reliability and concurrent validity of two smartphone-based inclinometer applications used for sagittal spinal curvature assessment.
The study will include healthy volunteers aged 18-25 years. Participants will be informed about the study procedures, and written informed consent will be obtained before enrollment. Demographic and anthropometric characteristics, including age, sex, height, body weight, and body mass index, will be recorded.
Measurement Procedures An experienced physiotherapist will identify and mark five anatomical reference points along the spine, extending from the cervical region to the lumbosacral region. These reference points will be used to standardize the measurement locations across devices and assessment sessions.
Sagittal spinal inclination angles will be measured using three different devices:
A conventional gravity-based bubble inclinometer. An Android smartphone equipped with an inclinometer application. An iOS smartphone equipped with an inclinometer application. Measurements will be performed at the same anatomical reference points using all three devices. The conventional inclinometer will serve as a reference instrument for evaluating the concurrent validity of the smartphone applications.
Reliability Assessment To evaluate intra-rater and inter-rater reliability, measurements will be performed by three assessors using a standardized assessment protocol.
Each measurement will be repeated twice during the initial assessment session. A second assessment session will be conducted 24-48 hours after the first session, during which the measurements will be repeated using the same three devices.
The repeated measurements will allow the evaluation of within-assessor consistency, agreement between different assessors, and measurement stability across assessment sessions.
Concurrent Validity Assessment The measurements obtained from the Android and iOS smartphone applications will be compared with those obtained using the conventional bubble inclinometer.
The agreement between the smartphone applications and the conventional inclinometer will be examined to determine whether smartphone-based measurements provide comparable results for sagittal spinal inclination assessment.
Statistical Analysis Descriptive statistics will be used to summarize participant characteristics and measurement results.
Intraclass correlation coefficients (ICCs) will be calculated to evaluate intra-rater reliability, inter-rater reliability, and test-retest reliability. Measurement error will be examined using the standard error of measurement (SEM) and minimal detectable change (MDC).
Concurrent validity will be assessed through correlation and agreement analyses. Pearson correlation coefficients, Lin's concordance correlation coefficients, and Bland-Altman analyses will be used to investigate the relationships, concordance, and systematic differences between measurements obtained using the smartphone applications and the conventional inclinometer.
Expected Contribution The study aims to provide evidence regarding the reliability and concurrent validity of smartphone-based inclinometer applications for assessing sagittal spinal inclination. The findings may help determine the potential clinical applicability of smartphone-based measurement tools in physiotherapy and rehabilitation assessments.
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Kontakty a umístění
Studijní místa
-
-
-
Kırşehir, Turecko (Türkiye), 40100
- Kırşehir Ahi Evran Üniversitesi
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
healthy older individuals
Popis
Inclusion Criteria:
- Being over 18 years of age,
- being able to stand and walk without an assistive device,
- not having experienced back pain or lower extremity pain in the last 6 months,
- and being willing to participate in the study.
Exclusion Criteria:
- Lack of consent,
- lower extremity injuries (dislocation, sprain) within one month prior to measurement,
- lower extremity fractures within the last 6 months,
- tactile sensitivity that prevents the adoption of a free and habitual posture.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Observační modely: COHORT
- Časové perspektivy: CROSS_SECTIONAL
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Assessment of Spinal Curvature
Časové okno: Two measurements taken 10 minutes apart.
|
Description: The following 5 parameters were used for the measurement: 1. ALPHA 1 angle of sacrum (upper beam of the inclinometer, in the middle of the intervertebral space, on the line connecting the posterior superior iliac crests). 2. ALPHA 2 angle - sacrolumbar junction S/L (center of the inclinometer on the line connecting the posterior superior iliac crests). 3. BETA angle - Th12-L1 thoracolumbar junction (center of the inclinometer at the thoracolumbar junction). 4. GAMMA angle - C7-Th1 (center of the inclinometer on C7). 5. DELTA angle - Th3-Th4 (upper beam of the inclinometer at the height of the upper angle of the scapula). |
Two measurements taken 10 minutes apart.
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Esra BAYRAMOĞLU DEMİRDÖĞEN, Kırşehir Eğitim ve Araştırma Hastanesi
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
Další identifikační čísla studie
- KAEU-EBAYRAMOGLUD-006
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .