Hyperoxemia and Oxygen Reserve Index During Neurointerventional Anesthesia
Arterial Hyperoxemia and Oxygen Reserve Index During Elective Neurointerventional Procedures Under General Anesthesia: A Prospective Observational Study
The goal of this observational study is to learn how often high blood oxygen levels (hyperoxemia) occur in adults receiving general anesthesia for planned (elective) neurointerventional procedures, such as brain aneurysm coiling or other catheter-based treatments of brain vessels. It will also look at how well a non-invasive finger sensor measurement called the Oxygen Reserve Index (ORi) reflects arterial oxygen levels.
The main questions it aims to answer are:
- How often is the arterial oxygen pressure (PaO2) 150 mmHg or higher in blood gas samples taken as part of routine care during these procedures?
- How does ORi relate to PaO2, and can ORi help identify high oxygen levels?
Participants will:
- Receive anesthesia and their procedure exactly as planned by their care team; the study does not change any treatment, oxygen setting, or ventilator setting.
- Have a painless ORi sensor placed on a finger, similar to a standard pulse oximeter, during anesthesia.
- Have their routine monitoring values and the results of arterial blood gas samples taken for routine clinical care recorded.
No extra blood samples will be taken for the study, and ORi values will not be used to guide care.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
Background and rationale:
Oxygen is routinely given during general anesthesia to prevent hypoxemia. However, oxygen given beyond the patient's needs may cause arterial hyperoxemia, which has been linked to vasoconstriction, oxidative stress, and absorption atelectasis. Normobaric hyperoxia has been shown to reduce cerebral blood flow, and cumulative hyperoxemia exposure has been associated with unfavorable outcomes in ventilated patients with aneurysmal subarachnoid hemorrhage. Although these findings come from critically ill populations, they provide a physiological rationale for describing arterial oxygen levels in patients undergoing elective neurointerventional procedures, in whom maintaining cerebral perfusion is essential.
Standard pulse oximetry (SpO2) plateaus at high arterial oxygen levels and cannot detect hyperoxemia. The Oxygen Reserve Index (ORi) is a continuous, non-invasive, dimensionless index (0 to 1) derived from multi-wavelength pulse co-oximetry, reported to reflect oxygenation changes in the moderately hyperoxic range (approximately PaO2 100-200 mmHg). The ORi-PaO2 relationship varies across populations and clinical settings, and it has not been described in stable adults undergoing elective neurointerventional procedures under general anesthesia.
Study design:
This is a single-center, prospective, observational study conducted at the Department of Anesthesiology and Reanimation and the Interventional Radiology Unit of University of Health Sciences Fatih Sultan Mehmet Training and Research Hospital, Istanbul, Türkiye. No randomization, group allocation, or clinical intervention will be performed.
Procedures:
Anesthesia induction and maintenance, ventilator settings, FiO2, fluids, vasoactive drugs, and all other management will follow the attending anesthesiologist's routine practice. In addition to standard monitoring, an ORi-capable pulse co-oximetry sensor will be applied. ORi values will be recorded by the investigator but will not be used for clinical decision-making, and no changes in FiO2, ventilation, or treatment will be made based on ORi.
ORi, SpO2, FiO2, heart rate, mean arterial pressure, end-tidal carbon dioxide, body temperature, perfusion index, and signal quality will be recorded at the following time points: 5 minutes after intubation and initiation of mechanical ventilation (T1), 30 minutes (T2) and 60 minutes (T3) after the start of the procedure, every 60 minutes thereafter starting at 120 minutes if the procedure continues (T4 onward), and at the end of the procedure before FiO2 is increased for emergence (Tend).
Whenever an arterial blood gas sample is drawn by the clinical team for routine care, PaO2, PaCO2, pH, SaO2, hemoglobin, and lactate will be recorded and matched with ORi, SpO2, FiO2, perfusion index, and hemodynamic values recorded at the time of sampling or within 1 minute. No additional blood samples will be drawn for research purposes, and the timing and number of routine samples will not be altered.
Patients without a routine arterial blood gas will remain in the cohort for descriptive analyses; PaO2-based analyses will include all valid matched ORi-PaO2 pairs.
Sample size and statistical analysis:
Assuming an expected hyperoxemia proportion of 50%, a 95% confidence level, and a precision of +/-10%, the minimum required sample size is 96 patients; 100 patients will be enrolled to account for missing data. The proportion of matched measurements with PaO2 >=150 mmHg will be reported with 95% confidence intervals. Repeated measurements will be analyzed with mixed-effects models. The ORi-PaO2 relationship, including possible nonlinearity and plateau behavior, will be evaluated with appropriate regression models. The ability of ORi to discriminate PaO2 >=150 and >=200 mmHg will be explored with ROC analysis, accounting for within-patient clustering. A p value <0.05 will be considered statistically significant.
Data protection:
All data will be de-identified, recorded on study case report forms, and used by the study team for scientific purposes only.
研究の種類
研究の種類
入学 (推定)
入学
連絡先と場所
研究連絡先
研究連絡先
- 名前:Cansu Ofluoglu, MD
- 電話番号:+905358640564
- メール:cansuakin.iu@gmail.com
研究場所
-
-
-
Istanbul、トルコ(Türkiye)、34000
- University of Health Sciences Fatih Sultan Mehmet Training and Research Hospital Scientific Research
-
コンタクト:
- Cansu Ofluoglu, MD
- 電話番号:+905358640564
- メール:cansuakin.iu@gmail.com
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
Adult patients (ASA I-III) scheduled for elective neurointerventional procedures under general anesthesia with routine invasive arterial monitoring at the Interventional Radiology Unit of University of Health Sciences Fatih Sultan Mehmet Training and Research Hospital, Istanbul, Türkiye. Eligible patients will be enrolled consecutively.
説明
Inclusion Criteria:
- Age 18 years or older
- American Society of Anesthesiologists (ASA) physical status I-III
- Scheduled for an elective neurointerventional procedure
- Procedure performed under general anesthesia
- Invasive arterial pressure monitoring and arterial blood gas sampling planned as part of routine clinical care
- Written informed consent obtained from the patient or, when required, the legal representative
Exclusion Criteria:
- Refusal to participate
- Emergency neurointerventional procedure
- ASA physical status IV or higher
- Pregnancy
- Mechanical ventilation before the procedure
- Chronic respiratory failure requiring long-term home oxygen therapy
- Severe peripheral circulatory impairment or technical signal failure preventing reliable ORi measurement
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:COHORT
- 時間の展望:PROSPECTIVE
グループ/コホートの数
コホートと介入
グループ/コホートグループ/コホート |
介入・治療介入・治療 |
|---|---|
|
Elective Neurointerventional Procedures Under General Anesthesia
Adult patients (ASA I-III) undergoing elective neurointerventional procedures under general anesthesia with routine invasive arterial pressure monitoring. All anesthetic, ventilatory, and oxygen management follows routine clinical practice. An ORi-capable pulse co-oximetry sensor is applied for observational recording only; ORi values are not used for clinical decisions. Routine monitoring data and results of arterial blood gas samples drawn for clinical care are recorded. No additional blood samples are taken for research purposes. |
Non-invasive ORi measurement via multi-wavelength pulse co-oximetry, recorded blinded to the anesthesia team and not used to guide care. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Proportion of Matched Arterial Blood Gas Measurements With PaO2 >=150 mmHg
時間枠:Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
Number of valid matched ORi-PaO2 measurement pairs with PaO2 >=150 mmHg divided by the total number of valid matched pairs, multiplied by 100. Only arterial blood gas samples drawn for routine clinical care and matched to a valid ORi value recorded at the time of sampling or within 1 minute are included. Reported with 95% confidence interval. |
Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Proportion of Matched Arterial Blood Gas Measurements With PaO2 >=200 mmHg
時間枠:Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
Number of valid matched ORi-PaO2 pairs with PaO2 >=200 mmHg divided by the total number of valid matched pairs, multiplied by 100, reported with 95% confidence interval. |
Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
|
Proportion of Patients With at Least One PaO2 >=150 mmHg and >=200 mmHg Measurement
時間枠:Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
Percentage of patients with at least one valid matched arterial blood gas measurement showing PaO2 >=150 mmHg, and separately >=200 mmHg, among patients with at least one valid matched measurement. |
Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
|
Per-Patient Proportion of Hyperoxemic Measurements
時間枠:Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
For each patient, the number of matched measurements with PaO2 >=150 mmHg (and >=200 mmHg) divided by that patient's total number of matched measurements, summarized across patients. |
Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
|
Perioperative Changes in ORi, SpO2, FiO2, and Hemodynamic Parameters
時間枠:Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
ORi (dimensionless, 0-1), SpO2 (%), FiO2 (%), heart rate (beats/min), mean arterial pressure (mmHg), end-tidal CO2 (mmHg), body temperature (degrees C), and perfusion index recorded at T1 (5 min after intubation), T2 (30 min), T3 (60 min), every 60 min thereafter from 120 min, and Tend (end of procedure before FiO2 increase). Changes over time analyzed with mixed-effects models. |
Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
|
Relationship Between ORi and PaO2
時間枠:Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
Association between ORi and PaO2 in matched measurement pairs, evaluated with linear and nonlinear regression models accounting for repeated measurements within patients, including assessment of a possible plateau in ORi at higher PaO2 values. |
Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
|
Discriminative Ability of ORi for PaO2 >=150 mmHg and >=200 mmHg
時間枠:Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
Area under the receiver operating characteristic curve (AUROC) of ORi for detecting PaO2 >=150 mmHg and >=200 mmHg in matched pairs, with optimal cut-off, sensitivity, and specificity. Exploratory analysis accounting for within-patient clustering. |
Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
|
Factors Associated With Hyperoxemia
時間枠:Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
Association of hyperoxemia (PaO2 >=150 mmHg) with patient characteristics (age, sex, body mass index, ASA class, comorbidities), anesthesia characteristics (FiO2, anesthesia duration), and procedure characteristics (procedure type, duration, contrast volume), evaluated with multivariable mixed-effects models. |
Intraoperative period, from intubation to the end of the procedure before FiO2 is increased for emergence (approximately 1-4 hours)
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (推定)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
キーワード
追加の関連 MeSH 用語
その他の研究ID番号
その他の研究ID番号
- FSM-ORİ-ANGİO-2026
- 2026/09-80 (その他の識別子:University of Health Sciences Fatih Sultan Mehmet Training and Research Hospital Scientific Research Ethics Committee)
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。