Kinesiology Taping Versus Self-Mobilization for Neck Pain Related to Prolonged Electronic Device Use
Effects of Kinesiology Taping Versus Self-Sustained Natural Apophyseal Glide Mobilization on Pain, Neck Disability, Cervical Proprioception, Respiratory Muscle Strength, and Upper Trapezius Muscle Activity in Individuals With Neck Pain Related to Prolonged Electronic Device Use: A Randomized Controlled Trial
The goal of this clinical trial is to learn whether kinesiology taping or self-mobilization better reduces neck pain in adults who use electronic devices for long periods each day. The main questions it aims to answer are:
- Does kinesiology taping or self-mobilization lead to greater reduction in neck pain after 4 weeks?
- Do the two treatments differ in their effects on neck-related disability, neck position sense, breathing muscle strength, and upper trapezius muscle activity?
Researchers will compare kinesiology taping with self-sustained natural apophyseal glide (self-SNAG) mobilization to see which approach is more effective.
Participants will:
- Be randomly assigned to one of the two treatment groups
- Receive kinesiology tape applied to the back of the neck every 4 days for 4 weeks, or learn and perform a towel-assisted neck self-mobilization exercise for 4 weeks
- Receive education on posture and self-management
- Complete assessments of pain, neck disability, neck position sense, breathing muscle strength, and neck-shoulder muscle activity at the start of the study, after 4 weeks, and 1 month later
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
Prolonged use of electronic devices is associated with sustained cervical flexion and altered activation of the cervicoscapular musculature, particularly the upper trapezius. Kinesiology taping and Mulligan self-mobilization are commonly used conservative approaches; however, their comparative effects on pain, cervical proprioception, respiratory muscle strength, and muscle activity in this population remain unclear.
In this single-blind, two-arm, parallel-group randomized controlled trial, adults with neck pain (VAS > 3/10) and a history of electronic device use of at least 4 hours per day during the preceding year will be randomized to kinesiology taping (8 applications over 4 weeks) or self-SNAG mobilization performed with mirror-based visual feedback. Both groups will receive standardized education on posture and self-management.
Bilateral upper trapezius surface electromyography will be recorded during isometric shoulder elevation using a wireless sEMG system, with electrode placement according to SENIAM guidelines, and normalized to maximum voluntary isometric contraction. A bilateral upper trapezius EMG asymmetry index will be derived from the normalized right- and left-side values.
Primary and secondary outcomes will be analyzed using linear mixed-effects models with random intercepts for participants. As a pre-specified secondary analysis, the association between baseline bilateral upper trapezius EMG asymmetry and change in pain intensity will be examined, including its interaction with treatment group.
研究の種類
研究の種類
入学 (推定)
入学
段階
段階
- 適用できない
連絡先と場所
研究連絡先
研究連絡先
- 名前:Emrah Zirek Assistant Professor, Ph. D.
- 電話番号:+905446457700
- メール:ezirek@bingol.edu.tr
研究場所
-
-
Bingöl
-
Bingoel、Bingöl、トルコ(Türkiye)、12000
- 募集
- Bingol University, Faculty of Physical Therapy and Rehabilitation
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Age 18 years or older
- Neck pain with an intensity greater than 3 on a 10-point Visual Analog Scale
- Use of electronic devices for at least 4 hours per day during the preceding year
- Willingness to participate and provision of written informed consent
Exclusion Criteria:
- Cervical or shoulder surgery within the past 6 months
- Previously diagnosed cervical pathology, including whiplash-associated disorder, cervical spondylolisthesis, disc herniation, or rheumatoid arthritis
- Current use of analgesics, opioids, or corticosteroids
- Skin allergy, open wounds, or skin lesions in the cervical region that preclude kinesiology tape application
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:Kinesiology Taping
Participants receive kinesiology tape (5 cm wide, 0.5 mm thick, water-resistant) applied to the posterior cervical region in a seated neutral position. A Y-strip is applied over the cervical extensors from T1-T2 to C1-C2 with approximately 25% tension, and a second strip is applied perpendicularly across C3-C6. The tape is reapplied every 4 days by a trained physiotherapist for a total of 8 applications over 4 weeks. Participants also receive standardized education on posture and self-management. |
Elastic therapeutic tape applied to the posterior cervical region (Y-strip over the cervical extensors with approximately 25% tension and a perpendicular strip across C3-C6), reapplied every 4 days for 8 applications over 4 weeks. |
|
アクティブコンパレータ:Self-SNAG Mobilization
Participants are trained by an experienced physiotherapist to perform towel-assisted self-administered sustained natural apophyseal glide (self-SNAG) mobilization at the C5 level, with mirror-based visual feedback. The end-range rotation position is sustained for 3 seconds, with 10 repetitions per session within a pain-free range, [frequency, e.g., once daily] for 4 weeks. Participants also receive standardized education on posture and self-management. |
Towel-assisted self-administered sustained natural apophyseal glide at C5 with mirror-based visual feedback, 10 repetitions per session with 3-second end-range holds, performed over 4 weeks. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in Neck Pain Intensity (Visual Analog Scale)
時間枠:Baseline and week 4 (end of intervention)
|
Neck pain intensity is assessed using a 10-point Visual Analog Scale (0 = no pain, 10 = worst imaginable pain). Higher scores indicate greater pain. |
Baseline and week 4 (end of intervention)
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in Neck-Related Disability (Neck Disability Index)
時間枠:Baseline, week 4, and week 8
|
Self-reported neck-related disability is assessed using the 10-item Neck Disability Index (total score 0-50). Higher scores indicate greater disability. |
Baseline, week 4, and week 8
|
|
Change in Cervical Joint Position Sense Error
時間枠:Baseline, week 4, and week 8
|
Cervical joint position sense error is measured in centimeters using a head-mounted laser pointer and a target placed 90 cm from the seated participant, following active cervical flexion, extension, and left and right rotation. The mean deviation across five repetitions per direction is recorded. Higher values indicate poorer proprioceptive accuracy. |
Baseline, week 4, and week 8
|
|
Change in Upper Trapezius Muscle Activity (Surface Electromyography)
時間枠:Baseline, week 4, and week 8
|
Bilateral upper trapezius activity is recorded with wireless surface electromyography during isometric shoulder elevation (three 7-second contractions) and expressed as root-mean-square amplitude normalized to maximum voluntary isometric contraction (%MVIC). |
Baseline, week 4, and week 8
|
|
Bilateral Upper Trapezius EMG Asymmetry Index
時間枠:Baseline, week 4, and week 8
|
EMG asymmetry is calculated from normalized right- and left-side upper trapezius activity as |Right - Left| / [(Right + Left) / 2] x 100. A value of 0% indicates perfect symmetry; higher values indicate greater bilateral imbalance. Baseline asymmetry will be examined as a predictor of change in pain intensity. |
Baseline, week 4, and week 8
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
その他の研究ID番号
- BINGOL-7-5
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
Individual participant data will not be shared publicly. De-identified data may be made available from the principal investigator upon reasonable request.
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。