Effect of Simethicone on Screening Colonoscopy
The Effect Of Adding High Dose Simethicone To A Standard Polyethylene Glycol Preparation On Adenoma Detection Rate During Screening Colonoscopy: A Randomized Controlled Pilot Trial
調査の概要
詳細な説明
研究の種類
入学 (実際)
段階
- フェーズ 4
連絡先と場所
研究場所
-
-
Texas
-
El Paso、Texas、アメリカ、79905
- Texas Tech University Health Sciences Center El Paso
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Patients between the ages of 30-80 scheduled for screening colonoscopy.
- Male and female patients
- Ambulatory patients
- Signed informed consent form
Exclusion Criteria:
- Previous colonic surgery
- Patient with mental/physical condition that impairs oral ingestion of preparation
- Allergy or hypersensitivity to simethicone
- Patients with limited mobility (bedridden patients)
- Patients with gastrointestinal obstruction
- Patients with gastroparesis
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:ふるい分け
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Simethicone solution + Polyethylenglycol
This arm of the study will include the patients assigned to take simethicone solution with their colon preparations ( 4L Polyethyleneglycol)
|
Patients will be assigned randomly to take Simethicone Solution plus polyethylenglycol
他の名前:
|
|
アクティブコンパレータ:Polyethylenglycol
This arm of the study will include the patients assigned to take a regular bowel preparation (4L Polyethylenglycol)
|
Patients in this arm will be randomly assigned to take polyethylenglycol as their regular bowel preparation
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Adenoma Detection Rate
時間枠:25 minutes
|
The number of adenomatous polyps removed at colonoscopy
|
25 minutes
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Withdrawal Times
時間枠:6-10 minutes
|
Amount spent withdrawing the scope during the colonoscopy
|
6-10 minutes
|
|
Colon Preparation
時間枠:25 minutes
|
Boston Bowel Preparation Scale (BBPS): scale that rates the quality of the colon preparation based on the amount of stool present. 0:solid stool that cannot be cleared; 1:areas not well seen due to residual stool and/or opaque liquid; 2:small fragments of stool and/or opaque liquid, but mucosa seen well; 3:no residual stool or opaque liquid seen. Score determined by adding the score of each individual segment of the colon (right side, transverse and left side). Scores range from 0 to 3 in each segment, therefore, a total composite score ranges from 0 (poor) to 9 (excellent). Bubble Score (BS): scale that rates the amount of bubbles present in the colon. 0:no or minimal bubbles; 1:bubbles covering up to half the luminal diameter; 2:bubbles covering the circumference of the lumen; 3:bubbles filling the entire lumen. Score determined the same way as BBPS score but in this case a total score of 0 is excellent and 9 is poor. |
25 minutes
|
|
Intraprocedural Use of Simethicone
時間枠:6-10 minutes
|
The number of colonoscopies during which the endoscopist requested simethicone to be flushed through the endoscope.
|
6-10 minutes
|
協力者と研究者
捜査官
- 主任研究者:Antonio H Mendoza-Ladd, MD、Texas Tech University Health Sciences Center, El Paso
出版物と役立つリンク
一般刊行物
- Yoo IK, Jeen YT, Kang SH, Lee JH, Kim SH, Lee JM, Choi HS, Kim ES, Keum B, Chun HJ, Lee HS, Kim CD. Improving of bowel cleansing effect for polyethylene glycol with ascorbic acid using simethicone: A randomized controlled trial. Medicine (Baltimore). 2016 Jul;95(28):e4163. doi: 10.1097/MD.0000000000004163.
- Park JJ, Lee SK, Jang JY, Kim HJ, Kim NH. The effectiveness of simethicone in improving visibility during colonoscopy. Hepatogastroenterology. 2009 Sep-Oct;56(94-95):1321-5.
- Hassan C, Fuccio L, Bruno M, Pagano N, Spada C, Carrara S, Giordanino C, Rondonotti E, Curcio G, Dulbecco P, Fabbri C, Della Casa D, Maiero S, Simone A, Iacopini F, Feliciangeli G, Manes G, Rinaldi A, Zullo A, Rogai F, Repici A. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol. 2012 May;10(5):501-6. doi: 10.1016/j.cgh.2011.12.037. Epub 2012 Jan 10.
- Rex DK, Petrini JL, Baron TH, Chak A, Cohen J, Deal SE, Hoffman B, Jacobson BC, Mergener K, Petersen BT, Safdi MA, Faigel DO, Pike IM. Quality indicators for colonoscopy. Gastrointest Endosc. 2006 Apr;63(4 Suppl):S16-28. doi: 10.1016/j.gie.2006.02.021. No abstract available.
- Moraveji S, Casner N, Bashashati M, Garcia C, Dwivedi A, Zuckerman MJ, Carrion A, Ladd AM. The role of oral simethicone on the adenoma detection rate and other quality indicators of screening colonoscopy: a randomized, controlled, observer-blinded clinical trial. Gastrointest Endosc. 2019 Jul;90(1):141-149. doi: 10.1016/j.gie.2019.03.018. Epub 2019 Mar 26.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。
Simethicone Solutionの臨床試験
-
Shandong University募集
-
Polyak, MaximilianHealth Resources and Services Administration (HRSA)完了
-
Martin-Luther-Universität Halle-Wittenbergまだ募集していません