- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT03119168
Effect of Simethicone on Screening Colonoscopy
The Effect Of Adding High Dose Simethicone To A Standard Polyethylene Glycol Preparation On Adenoma Detection Rate During Screening Colonoscopy: A Randomized Controlled Pilot Trial
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Detaljert beskrivelse
Studietype
Registrering (Faktiske)
Fase
- Fase 4
Kontakter og plasseringer
Studiesteder
-
-
Texas
-
El Paso, Texas, Forente stater, 79905
- Texas Tech University Health Sciences Center El Paso
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Patients between the ages of 30-80 scheduled for screening colonoscopy.
- Male and female patients
- Ambulatory patients
- Signed informed consent form
Exclusion Criteria:
- Previous colonic surgery
- Patient with mental/physical condition that impairs oral ingestion of preparation
- Allergy or hypersensitivity to simethicone
- Patients with limited mobility (bedridden patients)
- Patients with gastrointestinal obstruction
- Patients with gastroparesis
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Screening
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Dobbelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
---|---|
Eksperimentell: Simethicone solution + Polyethylenglycol
This arm of the study will include the patients assigned to take simethicone solution with their colon preparations ( 4L Polyethyleneglycol)
|
Patients will be assigned randomly to take Simethicone Solution plus polyethylenglycol
Andre navn:
|
Aktiv komparator: Polyethylenglycol
This arm of the study will include the patients assigned to take a regular bowel preparation (4L Polyethylenglycol)
|
Patients in this arm will be randomly assigned to take polyethylenglycol as their regular bowel preparation
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
---|---|---|
Adenoma Detection Rate
Tidsramme: 25 minutes
|
The number of adenomatous polyps removed at colonoscopy
|
25 minutes
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
---|---|---|
Withdrawal Times
Tidsramme: 6-10 minutes
|
Amount spent withdrawing the scope during the colonoscopy
|
6-10 minutes
|
Colon Preparation
Tidsramme: 25 minutes
|
Boston Bowel Preparation Scale (BBPS): scale that rates the quality of the colon preparation based on the amount of stool present. 0:solid stool that cannot be cleared; 1:areas not well seen due to residual stool and/or opaque liquid; 2:small fragments of stool and/or opaque liquid, but mucosa seen well; 3:no residual stool or opaque liquid seen. Score determined by adding the score of each individual segment of the colon (right side, transverse and left side). Scores range from 0 to 3 in each segment, therefore, a total composite score ranges from 0 (poor) to 9 (excellent). Bubble Score (BS): scale that rates the amount of bubbles present in the colon. 0:no or minimal bubbles; 1:bubbles covering up to half the luminal diameter; 2:bubbles covering the circumference of the lumen; 3:bubbles filling the entire lumen. Score determined the same way as BBPS score but in this case a total score of 0 is excellent and 9 is poor. |
25 minutes
|
Intraprocedural Use of Simethicone
Tidsramme: 6-10 minutes
|
The number of colonoscopies during which the endoscopist requested simethicone to be flushed through the endoscope.
|
6-10 minutes
|
Samarbeidspartnere og etterforskere
Etterforskere
- Hovedetterforsker: Antonio H Mendoza-Ladd, MD, Texas Tech University Health Sciences Center, El Paso
Publikasjoner og nyttige lenker
Generelle publikasjoner
- Yoo IK, Jeen YT, Kang SH, Lee JH, Kim SH, Lee JM, Choi HS, Kim ES, Keum B, Chun HJ, Lee HS, Kim CD. Improving of bowel cleansing effect for polyethylene glycol with ascorbic acid using simethicone: A randomized controlled trial. Medicine (Baltimore). 2016 Jul;95(28):e4163. doi: 10.1097/MD.0000000000004163.
- Park JJ, Lee SK, Jang JY, Kim HJ, Kim NH. The effectiveness of simethicone in improving visibility during colonoscopy. Hepatogastroenterology. 2009 Sep-Oct;56(94-95):1321-5.
- Hassan C, Fuccio L, Bruno M, Pagano N, Spada C, Carrara S, Giordanino C, Rondonotti E, Curcio G, Dulbecco P, Fabbri C, Della Casa D, Maiero S, Simone A, Iacopini F, Feliciangeli G, Manes G, Rinaldi A, Zullo A, Rogai F, Repici A. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol. 2012 May;10(5):501-6. doi: 10.1016/j.cgh.2011.12.037. Epub 2012 Jan 10.
- Rex DK, Petrini JL, Baron TH, Chak A, Cohen J, Deal SE, Hoffman B, Jacobson BC, Mergener K, Petersen BT, Safdi MA, Faigel DO, Pike IM. Quality indicators for colonoscopy. Gastrointest Endosc. 2006 Apr;63(4 Suppl):S16-28. doi: 10.1016/j.gie.2006.02.021. No abstract available.
- Moraveji S, Casner N, Bashashati M, Garcia C, Dwivedi A, Zuckerman MJ, Carrion A, Ladd AM. The role of oral simethicone on the adenoma detection rate and other quality indicators of screening colonoscopy: a randomized, controlled, observer-blinded clinical trial. Gastrointest Endosc. 2019 Jul;90(1):141-149. doi: 10.1016/j.gie.2019.03.018. Epub 2019 Mar 26.
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- E17034
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
produkt produsert i og eksportert fra USA
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .
Kliniske studier på Adenom tykktarm
-
The University of Hong KongQueen Mary Hospital, Hong KongFullført
-
Singapore General HospitalUkjent
-
Hospital Universitario de CanariasUkjent
-
Technical University of MunichFullført
-
Ningbo No. 1 HospitalFullført
-
Massachusetts General HospitalFullført
-
Changhai HospitalXiangya Hospital of Central South University; Fudan University; Xuzhou Central... og andre samarbeidspartnereRekruttering
-
Soonchunhyang University HospitalFullført
-
The University of Hong KongFullført
-
Hospital Universitario de CanariasUkjent
Kliniske studier på Simethicone Solution
-
Bausch & Lomb IncorporatedFullførtUheldig effekt av kontaktlinseløsningMalaysia
-
Milton S. Hershey Medical CenterLehigh Valley Hospital; St. Luke's Hospital, Pennsylvania; The Reading Hospital...Fullført
-
LG ChemAvsluttetDorsalt håndvolumtapKorea, Republikken
-
Yale UniversityRekrutteringKoronar bypass-graftkirurgi | Utskifting av aortaklaffenForente stater
-
Bausch & Lomb IncorporatedFullførtKontaktlinsebrukForente stater
-
LG ChemAvsluttet
-
Zimmer BiometFullført
-
Miltenyi Biotec, Inc.AvsluttetKoronararteriesykdom | Iskemisk kardiomyopatiForente stater
-
LG ChemFullførtFor å evaluere effektiviteten og sikkerheten til YVOIRE Y-Solution 720 injisert i midten av ansiktetVolumdefekter i midten av ansiktetKina
-
LG ChemFullførtKjevevolumunderskuddØsterrike, Polen