Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Effect of Simethicone on Screening Colonoscopy

3 de junho de 2019 atualizado por: Antonio Mendoza-Ladd, Texas Tech University Health Sciences Center, El Paso

The Effect Of Adding High Dose Simethicone To A Standard Polyethylene Glycol Preparation On Adenoma Detection Rate During Screening Colonoscopy: A Randomized Controlled Pilot Trial

This study is evaluating the effect of adding a high dose of simethicone to the standard polyethylene glycol preparation for screening colonoscopy in the quality of the preparation , adenoma detection rate and withdrawal times.

Visão geral do estudo

Status

Concluído

Condições

Descrição detalhada

A proper bowel preparation is key to a thorough and safe colonoscopy. Several factors affect the mucosal visualization during colonoscopy, and consequently the quality of such evaluation. Undoubtedly, this can have unfavorable implications like missed lesions. One of the most commonly encountered scenarios is the presence of multiple bubbles that interfere with mucosal visualization. When this occurs, simethicone (an antifoam agent used to reduce bloating when ingested orally) is injected through the colonoscope to eliminate the bubbles and get a clear view of the mucosa. A few studies have used oral simethicone in conjunction with oral preparation agents (PEG, magnesium citrate, sodium phosphate) in an attempt to improve the quality of the preparation. Unfortunately these studies have not used the exact same preparation agent with and without simethicone, making it difficult to draw conclusions on its efficacy. However, it is important to understand that simethicone is not intended to decrease the amount of stool in the colon, and it's purpose is to decrease the amount of bubbles interfering with the visualization of the mucosa provided that there is no stool present . Furthermore, it is unclear if adding simethicone to a standard bowel preparation makes a significant difference in key aspects of screening colonoscopy such as adenoma detection rate or withdrawal times. This prospective randomized controlled, observer blinded study at Texas Tech University Health Sciences Center in El Paso, aims at studying the effect of simethicone on the overall colon preparation as well as on adenoma detection rate and withdrawal times.

Tipo de estudo

Intervencional

Inscrição (Real)

268

Estágio

  • Fase 4

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Texas
      • El Paso, Texas, Estados Unidos, 79905
        • Texas Tech University Health Sciences Center El Paso

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

30 anos a 80 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  1. Patients between the ages of 30-80 scheduled for screening colonoscopy.
  2. Male and female patients
  3. Ambulatory patients
  4. Signed informed consent form

Exclusion Criteria:

  1. Previous colonic surgery
  2. Patient with mental/physical condition that impairs oral ingestion of preparation
  3. Allergy or hypersensitivity to simethicone
  4. Patients with limited mobility (bedridden patients)
  5. Patients with gastrointestinal obstruction
  6. Patients with gastroparesis

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Triagem
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Simethicone solution + Polyethylenglycol
This arm of the study will include the patients assigned to take simethicone solution with their colon preparations ( 4L Polyethyleneglycol)
Patients will be assigned randomly to take Simethicone Solution plus polyethylenglycol
Outros nomes:
  • mylicon
Comparador Ativo: Polyethylenglycol
This arm of the study will include the patients assigned to take a regular bowel preparation (4L Polyethylenglycol)
Patients in this arm will be randomly assigned to take polyethylenglycol as their regular bowel preparation

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Adenoma Detection Rate
Prazo: 25 minutes
The number of adenomatous polyps removed at colonoscopy
25 minutes

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Withdrawal Times
Prazo: 6-10 minutes
Amount spent withdrawing the scope during the colonoscopy
6-10 minutes
Colon Preparation
Prazo: 25 minutes

Boston Bowel Preparation Scale (BBPS): scale that rates the quality of the colon preparation based on the amount of stool present. 0:solid stool that cannot be cleared; 1:areas not well seen due to residual stool and/or opaque liquid; 2:small fragments of stool and/or opaque liquid, but mucosa seen well; 3:no residual stool or opaque liquid seen. Score determined by adding the score of each individual segment of the colon (right side, transverse and left side). Scores range from 0 to 3 in each segment, therefore, a total composite score ranges from 0 (poor) to 9 (excellent).

Bubble Score (BS): scale that rates the amount of bubbles present in the colon. 0:no or minimal bubbles; 1:bubbles covering up to half the luminal diameter; 2:bubbles covering the circumference of the lumen; 3:bubbles filling the entire lumen. Score determined the same way as BBPS score but in this case a total score of 0 is excellent and 9 is poor.

25 minutes
Intraprocedural Use of Simethicone
Prazo: 6-10 minutes
The number of colonoscopies during which the endoscopist requested simethicone to be flushed through the endoscope.
6-10 minutes

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Antonio H Mendoza-Ladd, MD, Texas Tech University Health Sciences Center, El Paso

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Publicações Gerais

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

15 de março de 2017

Conclusão Primária (Real)

10 de abril de 2019

Conclusão do estudo (Real)

10 de abril de 2019

Datas de inscrição no estudo

Enviado pela primeira vez

10 de abril de 2017

Enviado pela primeira vez que atendeu aos critérios de CQ

13 de abril de 2017

Primeira postagem (Real)

18 de abril de 2017

Atualizações de registro de estudo

Última Atualização Postada (Real)

5 de junho de 2019

Última atualização enviada que atendeu aos critérios de controle de qualidade

3 de junho de 2019

Última verificação

1 de junho de 2019

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Sim

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Sim

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em Adenoma de cólon

Ensaios clínicos em Simethicone Solution

Se inscrever