神経迷走神経刺激と脳性麻痺
Acute Effects of Transcutaneous Auricular Vagus Nerve Stimulation on Autonomic Nervous System Regulation and Spasticity in Children With Spastic Cerebral Palsy: A Preliminary Study
This study investigated the acute effects of transcutaneous auricular vagus nerve stimulation (taVNS) on autonomic nervous system regulation and spasticity in children with spastic cerebral palsy. A total of 20 children aged 2-15 years participated in this prospective, single-group pretest-posttest study. All participants received a single 20-minute session of bilateral taVNS. Autonomic nervous system regulation was assessed using heart rate variability (HRV) parameters, while spasticity was evaluated using the Modified Ashworth Scale (MAS). Measurements were performed before and after the intervention to investigate the immediate effects of taVNS.
調査の概要
詳細な説明
This prospective, single-group pretest-posttest clinical study investigated the acute effects of transcutaneous auricular vagus nerve stimulation (taVNS) on autonomic nervous system regulation and spasticity in children with spastic cerebral palsy (CP). The study was conducted at the Physical Medicine and Rehabilitation Department of Bursa VM Medical Park Hospital, Türkiye, between January and March 2025.
A total of 20 children aged 2-15 years with a diagnosis of spastic cerebral palsy were included. All participants completed the study, and no dropouts occurred.
Assessment Procedures
Participants' demographic characteristics, including age, sex, height, weight, and body mass index, were recorded. Gross motor function was classified using the Gross Motor Function Classification System (GMFCS).
Spasticity was assessed using the Modified Ashworth Scale (MAS), which evaluates resistance to passive movement. Bilateral elbow flexors, wrist flexors, knee extensors, and ankle plantar flexors were assessed, resulting in eight individual scores per participant. The mean of these scores was used as the composite MAS score.
Autonomic nervous system regulation was evaluated through heart rate variability (HRV) measurements using the Elite HRV device. The recorded parameters included average heart rate, root mean square of successive differences (RMSSD), percentage of successive normal-to-normal intervals differing by more than 50 milliseconds (pNN50), low-frequency power (LF), high-frequency power (HF), and the LF/HF ratio.
HRV measurements were obtained during a one-minute recording period in the seated position with guided breathing.
Intervention
All participants received a single 20-minute session of bilateral transcutaneous auricular vagus nerve stimulation using the Vagustim device. Electrodes were positioned on the concha and tragus regions of both ears.
Stimulation was delivered using biphasic current at a frequency of 10 Hz and a pulse width of 300 microseconds. Stimulation intensity was gradually increased to the maximum comfortable level tolerated by each participant. The mean applied intensity was 0.8 ± 0.3 mA.
Participants were positioned supine during stimulation.
Assessment Timeline
Before the intervention, participants rested in a seated position for five minutes, followed by a one-minute HRV recording and MAS assessment.
Following the 20-minute taVNS session, participants returned to a seated position and rested for five minutes before the post-intervention HRV measurement. Spasticity was subsequently reassessed using the MAS.
The primary outcomes were changes in HRV parameters and spasticity following the single taVNS session.
Statistical Analysis
Data were analyzed using IBM SPSS Statistics version 28.0. Normality was assessed using the Kolmogorov-Smirnov and Shapiro-Wilk tests. Paired-samples t-tests were used for normally distributed variables, while Wilcoxon signed-rank tests were applied to non-normally distributed variables. Spearman correlation analysis was performed to examine associations between GMFCS levels and changes in spasticity and autonomic nervous system parameters.
Statistical significance was set at p < 0.05.
All 20 participants completed the intervention and assessments, with no missing data or reported adverse events.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Bursa
-
Bursa、Bursa、トルコ(Türkiye)、16160
- Mudanya University
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
Children aged 2-15 years diagnosed with spastic cerebral palsy (CP) by a physical medicine and rehabilitation specialist or neurologist.
Written informed consent provided by parents or legal guardians and willingness of the child to participate.
Clinical stability without acute illness or comorbidities that could affect autonomic function or spasticity.
Exclusion Criteria:
Severe intellectual disability preventing understanding of or participation in study procedures.
Uncontrolled cardiovascular, respiratory, or autonomic disorders (e.g., arrhythmia or severe asthma).
Presence of medical devices potentially affected by vagus nerve stimulation (e.g., pacemakers or cochlear implants).
Risk of vagus nerve stimulation interacting with antiepileptic medication or triggering epileptic seizures.
Inability of the child or parent/legal guardian to comply with the study protocol or cooperate with study procedures.
Botulinum toxin injections within the previous three months.
Initiation or dose adjustment of oral antispastic medications (e.g., baclofen, tizanidine, or diazepam) within the previous month.
Initiation of a new rehabilitation program or intensification of an existing rehabilitation program within the previous four weeks.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:nervus vagus stimulation
All 20 participants received a single 20-minute session of bilateral transcutaneous auricular vagus nerve stimulation (taVNS) using the Vagustim device. Stimulation was delivered through electrodes positioned on the concha and tragus regions of both ears, using biphasic current at a frequency of 10 Hz and a pulse width of 300 microseconds. Stimulation intensity was gradually increased to the maximum comfortable level tolerated by each participant. Spasticity and heart rate variability (HRV) parameters were assessed before and after the intervention to evaluate its acute effects. |
Transcutaneous auricular vagus nerve stimulation (taVNS) was administered bilaterally using the Vagustim device (Vagustim Medical Technologies, Istanbul, Türkiye). Participants received a single 20-minute stimulation session in the supine position. Electrodes were placed on the concha and tragus regions of both ears. Stimulation was delivered using biphasic current at a frequency of 10 Hz and a pulse width of 300 microseconds. The stimulation intensity was gradually increased to the maximum level tolerated by each participant. The mean applied stimulation intensity was 0.8 ± 0.3 mA (range: 0.4-1.5 mA). |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Spasticity Assessed Using the Modified Ashworth Scale (MAS)
時間枠:The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
Spasticity was assessed using the Modified Ashworth Scale (MAS), which evaluates resistance to passive movement on a scale ranging from 0 (normal muscle tone) to 4 (complete rigidity). Bilateral elbow flexors, wrist flexors, knee extensors, and ankle plantar flexors were evaluated, yielding eight individual scores per participant. The mean of these eight scores was calculated as the composite MAS score. Higher scores indicated greater spasticity. Measurements were performed before and after the intervention to assess acute changes in spasticity following a single session of transcutaneous auricular vagus nerve stimulation (taVNS). |
The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
|
Autonomic Nervous System Activity Value/RMSSD
時間枠:The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
The autonomic nervous system cannot be directly evaluated through physiological tests. However, advancements in technology have introduced methods like heart rate variability (HRV) analysis, widely used in scientific research. HRV analysis measures RR waves during rest and will be employed in this study using the Elite HRV Corsense device. Key parameters include: RMSSD: Reflects parasympathetic activity and forms the basis of HRV and and is expressed in milliseconds |
The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
|
Autonomic nervous system activity/ LF Power
時間枠:The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
The autonomic nervous system cannot be directly evaluated through physiological tests. However, advancements in technology have introduced methods like heart rate variability (HRV) analysis, widely used in scientific research. HRV analysis measures RR waves during rest and will be employed in this study using the Elite HRV Corsense device.LF Power: Indicates sympathetic activity (0.04-0.15 Hz range) and t is expressed as the square of milliseconds |
The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
|
Autonomic nervous system activity / HF Power
時間枠:The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
The autonomic nervous system cannot be directly evaluated through physiological tests. However, advancements in technology have introduced methods like heart rate variability (HRV) analysis, widely used in scientific research. HRV analysis measures RR waves during rest and will be employed in this study using the Elite HRV Corsense device.HF Power: Represents parasympathetic activity (0.15-0.40 Hz range) and t is expressed as the square of milliseconds |
The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
|
Autonomic nervous system activity - LF/HF
時間枠:The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
The autonomic nervous system cannot be directly evaluated through physiological tests. However, advancements in technology have introduced methods like heart rate variability (HRV) analysis, widely used in scientific research. HRV analysis measures RR waves during rest and will be employed in this study using the Elite HRV Corsense device.LF/HF Ratio: Measures sympathovagal balance. |
The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
|
Heart Rate
時間枠:The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
HRV analysis measures RR waves during rest and will be employed in this study using the Elite HRV Corsense device.The participants' average heart rate will be recorded in beats per minute (bpm). |
The assessments will be conducted before and immediately after the application of vagus nerve stimulation (VNS).
|
協力者と研究者
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- E-10840098-202.3.02-526
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。