膝の変形性関節症に対するバイオフィラーPRPアプリケーションの効果の評価
Effect of Biofiller PRP on Function, Pain Level, and Femoral Cartilage Thickness in Knee Osteoarthritis: a Randomized Clinical Study
The aim of this study is to evaluate the effects of biofiller PRP on function, pain level, and femoral cartilage thickness in knee osteoarthritis: a randomized clinical study
調査の概要
詳細な説明
Patients who are admitted and diagnosed with knee osteoarthritis based on anamnesis, physical examination and imaging methods are included in the study
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Konya、トルコ(Türkiye)
- NEU
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
1-45-65 years old 2-Diagnosis of knee OA according to ACR clinical and radiological diagnostic criteria 3-Kellgren Lawrence stage II or III 4-Knee pain for at least 6 months 5-Visual analog scale (VAS) score of at least 3 or more
Exclusion Criteria:
1 - History of surgery or traumatic injury 2-Inflammatory arthritis 3-History of cancer, bleeding diathesis and psychiatric disease 4-Those who have a disease that limits their participation in exercises (severe chronic obstructive lung disease, severe heart failure, history of cerebrovascular events) 5-Hip and ankle problems 6-Participating in another physical therapy program in the last 3 months 7-History of intra-articular injections in the last 6 months
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Biofiller platelet rich plasma
Ten ml of the patient's blood wasdrawn in a syringe . It wascentrifuged firstat 4000 rotations per minute (RPM)for 10 min . The upper part,i.e.,platelet-poor plasma (PPP) was withdrawn in a 5 mL syringe. PRP was incubated in hot incubator at 75 °C for 10 min and then cooled in a refrigerator for 5 min. |
Biofiller platelet rich plasma Arm Description: Ten ml of the patient's blood wasdrawn in a syringe . It wascentrifuged firstat 4000 rotations per minute (RPM)for 10 min . The upper part,i.e.,platelet-poor plasma (PPP) was withdrawn in a 5 mL syringe. PRP was incubated in hot incubator at 75 °C for 10 min and then cooled in a refrigerator for 5 min. |
|
アクティブコンパレータ:Platelet rich plasma
Ten ml of the patient's blood wasdrawn in a syringe . It wascentrifuged firstat 4000 rotations per minute (RPM)for 10 min . |
Biofiller platelet rich plasma Arm Description: Ten ml of the patient's blood wasdrawn in a syringe . It wascentrifuged firstat 4000 rotations per minute (RPM)for 10 min . The upper part,i.e.,platelet-poor plasma (PPP) was withdrawn in a 5 mL syringe. PRP was incubated in hot incubator at 75 °C for 10 min and then cooled in a refrigerator for 5 min. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Visual Analog Scale (VAS) Change from baseline in pain on the VAS at month 3
時間枠:Baseline and month 3
|
Visual Analog Scale (VAS) is used to measure and monitor the intensity of pain. This is a 10 cm ruler that describes painlessness at one end and the most severe pain at the other. A patient scores his/her pain from 0 to 10. |
Baseline and month 3
|
|
Western OntarioMacMaster (WOMAC) Change from baseline in pain and physical functions on Western OntarioMacMaster scale at month
時間枠:Baseline and month 3
|
It is widely used in studies with knee OA patients. The scale, each question of which is evaluated with a 5-point Likert scale, consists of 24 questions. It is filled by patients. There are pain, physical function and stiffness subscales. Pain subscale is evaluated with five items and is scored between 0-20. The hardness subscale has two items and is scored between 0-8. Function subscale consists of 17 items and is scored between 0-68. A high score indicates poor function, pain or stiffness. |
Baseline and month 3
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Femoral cartilage thickness Change from baseline in knee joint on the measuring the femoral cartilage thickness at month 3
時間枠:Baseline and month 3
|
Femoral cartilage thickness is measured by the same physician by placing the probe axially in the suprapatellar region by ultrasonography while the patient is lying on his back and the knees are in maximum flexion. The distance between the thin hyperechoic line at the synovial cartilage interface and the sharp hyperechoic line at the cartilage-bone interface is defined as cartilage thickness |
Baseline and month 3
|
協力者と研究者
捜査官
- 主任研究者:BANU ORDAHAN、Necmettin Erbakan University, Konya, Turkey
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。