Inertial Sensors Used to Learn Manipulation

2014년 12월 3일 업데이트: Dr. Antonio I Cuesta-Vargas, University of Malaga

EFFECT OF REAL-TIME FEEDBACK THROUGH INERTIAL SENSORS IN LEARNING POSTEROANTERIOR THORACIC MANIPULATION

  • Background Context: no studies have been identified to analyse the effect of real time feedback (using inertial sensors) on physiotherapy students learning the art of posterior-anterior thoracic manipulation (PATM).
  • Purpose: to study the effect caused by real-time feedback on the learning process for PATM, comparing two undergraduate physiotherapy student groups. Hypothesis: significant differences will exist in the execution parameters of manipulation among students receiving real-time feedback versus those who do not.
  • Study Design/Setting: longitudinal, pre-post intervention.
  • Patient Sample: Sixty-one undergraduate physiotherapy students were divided randomly into two groups, G1 (n = 31) (group without feedback in real time) and G2 (n = 30) (group with real-time feedback).
  • Outcome Measures: time, displacement and velocity and improvement (only between groups) to reach maximum peak, to reach minimum peak from maximum peak, total manipulation time.
  • Methods: two groups of physiotherapy students learned PATM, one using a traditional method and the other using real-time feedback (inertial sensor). Measures were obtained pre- and post-intervention. Intragroup pre- and post-intervention and intergroup post-intervention scores were calculated. An analysis of the measures' stability was developed through an ICC (1,2).
  • Results: the values of ICC ranged from 0.881 to 0.997. Statistically significant differences were found in all variables analysed (intra- and inter-group) in favour of G2.
  • Conclusions: the learning process for posterior-anterior thoracic manipulation is facilitated when the student receives real-time feedback.

연구 개요

상태

완전한

정황

개입 / 치료

연구 유형

중재적

등록 (실제)

64

단계

  • 해당 없음

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

예

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Participants did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

Exclusion Criteria:

  • Refusal to participate in the study

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 할당: 무작위
  • 중재 모델: 크로스오버 할당
  • 마스킹: 더블

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: Real Time Feedback
Before beginning practice, one of the teachers performed the manipulation and explained the graph parameters as real-time feedback to consider when interpreting the graph, leaving the graphic as the benchmark execution
Before beginning practice, one of the teachers performed the manipulation and explained the graph parameters as real-time feedback to consider when interpreting the graph, leaving the graphic as the benchmark execution
활성 비교기: Tradicional Learning Method
Two expert teachers in manual therapy provided indications and corrections to the group with a teacher - student ratio of 1:8
Two expert teachers in manual therapy provided indications and corrections to the group with a teacher - student ratio of 1:8.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Change from displacement maximum peak (seconds)
기간: baseline; post-education; 24 weeks follow up
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
baseline; post-education; 24 weeks follow up
Change from Time to reach maximum peak (seconds)
기간: baseline; post-education; 24 weeks follow up
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
baseline; post-education; 24 weeks follow up
Change from Displacement between maximum and minimum peak (milimitres)
기간: baseline; post-education; 24 weeks follow up
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
baseline; post-education; 24 weeks follow up
Change from Total manipulation time (seconds)
기간: baseline; post-education; 24 weeks follow up
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
baseline; post-education; 24 weeks follow up
Change from Velocity to reach maximum peak (degrees per second)
기간: baseline; post-education; 24 weeks follow up
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
baseline; post-education; 24 weeks follow up
Change from Time to reach peak minimum from maximum peak (seconds)
기간: baseline; post-education; 24 weeks follow up
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
baseline; post-education; 24 weeks follow up
Change from Velocity to reach minimum peak from maximum peak (degress/second)
기간: baseline; post-education; 24 weeks follow up
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
baseline; post-education; 24 weeks follow up

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

수사관

  • 수석 연구원: Manuel González-Sánchez, PT, PhD, University of Malaga
  • 수석 연구원: Yves Lenfant, PT, University of Malaga

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작

2012년 2월 1일

기본 완료 (실제)

2012년 6월 1일

연구 완료 (실제)

2012년 9월 1일

연구 등록 날짜

최초 제출

2013년 7월 23일

QC 기준을 충족하는 최초 제출

2013년 7월 29일

처음 게시됨 (추정)

2013년 7월 30일

연구 기록 업데이트

마지막 업데이트 게시됨 (추정)

2014년 12월 4일

QC 기준을 충족하는 마지막 업데이트 제출

2014년 12월 3일

마지막으로 확인됨

2013년 7월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • ACuesta07072013

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .