Inertial Sensors Used to Learn Manipulation
EFFECT OF REAL-TIME FEEDBACK THROUGH INERTIAL SENSORS IN LEARNING POSTEROANTERIOR THORACIC MANIPULATION
- Background Context: no studies have been identified to analyse the effect of real time feedback (using inertial sensors) on physiotherapy students learning the art of posterior-anterior thoracic manipulation (PATM).
- Purpose: to study the effect caused by real-time feedback on the learning process for PATM, comparing two undergraduate physiotherapy student groups. Hypothesis: significant differences will exist in the execution parameters of manipulation among students receiving real-time feedback versus those who do not.
- Study Design/Setting: longitudinal, pre-post intervention.
- Patient Sample: Sixty-one undergraduate physiotherapy students were divided randomly into two groups, G1 (n = 31) (group without feedback in real time) and G2 (n = 30) (group with real-time feedback).
- Outcome Measures: time, displacement and velocity and improvement (only between groups) to reach maximum peak, to reach minimum peak from maximum peak, total manipulation time.
- Methods: two groups of physiotherapy students learned PATM, one using a traditional method and the other using real-time feedback (inertial sensor). Measures were obtained pre- and post-intervention. Intragroup pre- and post-intervention and intergroup post-intervention scores were calculated. An analysis of the measures' stability was developed through an ICC (1,2).
- Results: the values of ICC ranged from 0.881 to 0.997. Statistically significant differences were found in all variables analysed (intra- and inter-group) in favour of G2.
- Conclusions: the learning process for posterior-anterior thoracic manipulation is facilitated when the student receives real-time feedback.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Participants did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
Exclusion Criteria:
- Refusal to participate in the study
Studijní plán
Jak je studie koncipována?
Detaily designu
- Přidělení: Randomizované
- Intervenční model: Crossover Assignment
- Maskování: Dvojnásobek
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Experimentální: Real Time Feedback
Before beginning practice, one of the teachers performed the manipulation and explained the graph parameters as real-time feedback to consider when interpreting the graph, leaving the graphic as the benchmark execution
|
Before beginning practice, one of the teachers performed the manipulation and explained the graph parameters as real-time feedback to consider when interpreting the graph, leaving the graphic as the benchmark execution
|
|
Aktivní komparátor: Tradicional Learning Method
Two expert teachers in manual therapy provided indications and corrections to the group with a teacher - student ratio of 1:8
|
Two expert teachers in manual therapy provided indications and corrections to the group with a teacher - student ratio of 1:8.
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Change from displacement maximum peak (seconds)
Časové okno: baseline; post-education; 24 weeks follow up
|
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM.
The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor.
The manikin has a ribcage with a deformation capacity similar to that of a human thorax.
This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students.
The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
|
baseline; post-education; 24 weeks follow up
|
|
Change from Time to reach maximum peak (seconds)
Časové okno: baseline; post-education; 24 weeks follow up
|
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM.
The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor.
The manikin has a ribcage with a deformation capacity similar to that of a human thorax.
This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students.
The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
|
baseline; post-education; 24 weeks follow up
|
|
Change from Displacement between maximum and minimum peak (milimitres)
Časové okno: baseline; post-education; 24 weeks follow up
|
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM.
The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor.
The manikin has a ribcage with a deformation capacity similar to that of a human thorax.
This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students.
The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
|
baseline; post-education; 24 weeks follow up
|
|
Change from Total manipulation time (seconds)
Časové okno: baseline; post-education; 24 weeks follow up
|
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM.
The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor.
The manikin has a ribcage with a deformation capacity similar to that of a human thorax.
This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students.
The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
|
baseline; post-education; 24 weeks follow up
|
|
Change from Velocity to reach maximum peak (degrees per second)
Časové okno: baseline; post-education; 24 weeks follow up
|
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM.
The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor.
The manikin has a ribcage with a deformation capacity similar to that of a human thorax.
This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students.
The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
|
baseline; post-education; 24 weeks follow up
|
|
Change from Time to reach peak minimum from maximum peak (seconds)
Časové okno: baseline; post-education; 24 weeks follow up
|
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM.
The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor.
The manikin has a ribcage with a deformation capacity similar to that of a human thorax.
This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students.
The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
|
baseline; post-education; 24 weeks follow up
|
|
Change from Velocity to reach minimum peak from maximum peak (degress/second)
Časové okno: baseline; post-education; 24 weeks follow up
|
An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM.
The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor.
The manikin has a ribcage with a deformation capacity similar to that of a human thorax.
This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students.
The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.
|
baseline; post-education; 24 weeks follow up
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Manuel González-Sánchez, PT, PhD, University of Malaga
- Vrchní vyšetřovatel: Yves Lenfant, PT, University of Malaga
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
Další identifikační čísla studie
- ACuesta07072013
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .