소아 집중치료 중인 삽관 소아에서 심초음파를 통한 중심정맥압 추정 (PVCECHO)
소아 집중치료 중인 삽관 소아의 심초음파를 통한 중심정맥압 추정: 전향적 다기관 연구
Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU.
The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP.
When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies.
The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time.
The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
상세 설명
Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU.
The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP.
When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies.
The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time.
The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.
연구 유형
연구 유형
등록 (실제)
등록
연락처 및 위치
연구 장소
-
-
-
Paris, 프랑스, 75019
- Robert Debre Hospital
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
Intubated pediatric patients in an PICU
설명
Inclusion Criteria:
- Newborns and children from 2 days post term to 12 years Mechanical ventilation
- Carriers of a central venous catheter in the superior vena cava and ending in the right atrium"
Exclusion Criteria:
-
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 관찰 모델: COHORT
- 시간 관점: PROSPECTIVE
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
The correlation between the measurement of the Collapsibility Index, the Distensibility Index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the Abdominal Aorta with the measurement of the CVP.
기간: 1 day
|
Correlation coefficient value between CI, DI, and IVC dmax /AO measurements and reference method CVP measurement |
1 day
|
공동 작업자 및 조사자
수사관
수사관
- 수석 연구원: Perrine SEE, MD, Assistace Publique Hopitaux de Paris
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (실제)
기본 완료
연구 완료 (실제)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
기타 연구 ID 번호
- APHP21
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .