Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Odhad centrálního venózního tlaku echokardiografií u intubovaných dětí v pediatrické intenzivní péči (PVCECHO)

4. listopadu 2026 aktualizováno: Assistance Publique - Hôpitaux de Paris

Odhad centrálního venózního tlaku pomocí echokardiografie u intubovaných dětí v pediatrické intenzivní péči: prospektivní multicentrická studie

Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU.

The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP.

When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies.

The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time.

The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.

Přehled studie

Postavení

Dokončeno

Podmínky

Intervence / Léčba

Detailní popis

Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU.

The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP.

When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies.

The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time.

The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.

Typ studie

Pozorovací

Zápis (Aktuální)

120

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Paris, Francie, 75019
        • Robert Debre Hospital

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

2 dny až 12 let (Dítě)

Přijímá zdravé dobrovolníky

N/A

Pohlaví způsobilá ke studiu

Všechno

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

Intubated pediatric patients in an PICU

Popis

Inclusion Criteria:

  • Newborns and children from 2 days post term to 12 years Mechanical ventilation
  • Carriers of a central venous catheter in the superior vena cava and ending in the right atrium"

Exclusion Criteria:

-

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Observační modely: COHORT
  • Časové perspektivy: PROSPECTIVE

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
The correlation between the measurement of the Collapsibility Index, the Distensibility Index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the Abdominal Aorta with the measurement of the CVP.
Časové okno: 1 day

Correlation coefficient value between CI, DI, and IVC dmax /AO measurements and reference method CVP measurement

1 day

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Sponzor

Vyšetřovatelé

  • Vrchní vyšetřovatel: Perrine SEE, MD, Assistace Publique Hopitaux de Paris

Publikace a užitečné odkazy

Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

3. listopadu 2021

Primární dokončení (Aktuální)

3. listopadu 2022

Dokončení studie (Aktuální)

3. listopadu 2022

Termíny zápisu do studia

První předloženo

4. ledna 2022

První předloženo, které splnilo kritéria kontroly kvality

4. ledna 2022

První zveřejněno (Aktuální)

19. ledna 2022

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

6. listopadu 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

4. listopadu 2026

Naposledy ověřeno

1. listopadu 2026

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • APHP21

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NEROZHODNÝ

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .