Observational and Prospective Diagnostic Validation Study of the SMARTwatch for ST-segment Elevation Myocardial Infarction in Health Area of Cartagena

The main symptom that initiates the diagnostic and therapeutic process for patients with suspected acute coronary syndrome is chest pain. Based on a standard 12-lead electrocardiogram (ECG), patients can be diagnosed with ST-segment elevation myocardial infarction (STEMI), which requires immediate medical treatment. Recently, wearable devices like smartwatches with ECG capabilities have opened new pathways for cardiac triage, but their diagnostic precision and technical viability in a real, unselected Emergency Department setting need to be confirmed.

The primary objective of this prospective, observational study is to compare the diagnostic capacity of a 9-lead ECG obtained with a smartwatch against the standard 12-lead ECG for diagnosing STEMI in patients consulting for chest pain.

During the study, patients evaluated by the on-call cardiologist for ischemic chest pain will undergo their standard care. In addition to the standard 12-lead ECG, a 9-lead ECG will be sequentially recorded using a smartwatch. This is an observational study, meaning the smartwatch recording will not cause any delay in clinical action or negatively impact the patient's standard treatment.

Specifically, the study aims to:

  • Analyze the diagnostic agreement between expert cardiologists when blindly and independently classifying the smartwatch recordings versus the standard ECG recordings as "STEMI" or "non-STEMI".
  • Evaluate the technical feasibility of using the smartwatch in an Emergency Department setting by assessing the percentage of unreadable records due to artifacts.

연구 개요

상태

모병

정황

개입 / 치료

상세 설명

Background and Rationale:

The clinical spectrum of acute coronary syndrome (ACS) is broad, with chest pain being the primary symptom initiating the diagnostic and therapeutic cascade. In patients with ST-segment elevation myocardial infarction (STEMI), immediate reperfusion -primarily via percutaneous coronary intervention (PCI)-is crucial. While primary PCI has significantly reduced mortality, minimizing systemic delays remains vital.

Recently, wearable devices with electrocardiographic (ECG) capabilities have emerged as potential tools for ultra-early cardiac triage. Previous research, such as the SMARTAMI study, demonstrated that a sequential 9-lead smartwatch ECG has high sensitivity and specificity for detecting STEMI. However, these prior studies often compared confirmed myocardial infarction cases with healthy, asymptomatic cohorts in highly controlled environments. There is a critical need to validate the technical feasibility, signal quality, and diagnostic accuracy of this technology in a real-world Emergency Department (ED) setting with unselected patients, where factors like diaphoresis, acute pain, and time urgency complicate the recording process.

Study Design and Clinical Procedures:

This is a prospective, observational diagnostic validation and concordance study conducted in a real-world clinical setting. Patients evaluated by the on-call cardiologist for ischemic-profile chest pain will be consecutively enrolled. The study is purely observational; obtaining the smartwatch ECG will not delay standard clinical care, and standard medical management will remain unaltered.

Following standard protocols, an analog sequential 9-lead ECG (I, II, III, V1-V6) will be recorded using a smartwatch alongside the standard 12-lead ECG.

Blinding and Data Evaluation:

A rigorous double-blind, independent analysis will be performed. The on-call cardiologists responsible for acquiring the tracings in the ED will not participate in their interpretation. Both the standard 12-lead ECGs and the smartwatch ECGs will be completely anonymized using unique alphanumeric codes. Subsequently, independent expert cardiologists will blindly evaluate the tracings, classifying them as "STEMI" or "non-STEMI" without any knowledge of the patient's clinical data or the origin of each specific recording.

Statistical Approach and Sample Size:

Based on prior literature in controlled settings reporting a 93% sensitivity, this real-world study conservatively estimates an 85% expected sensitivity due to ED-specific variables (e.g., signal noise, diaphoresis). To achieve a 10% margin of error with a 95% confidence level, a sample size of 49 confirmed STEMI positive cases is required. Consecutive recruitment will continue uninterrupted until this target is reached. Patients enrolled during this period who are ultimately diagnosed as "non-STEMI" will be retained in the database to calculate the specificity of the device.

연구 유형

관찰

등록 (추정된)

100

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Murcia
      • Cartagena, Murcia, 스페인, 30202
        • 모병
        • Hospital General Universitario Santa Lucía
        • 연락하다:
        • 연락하다:
        • 수석 연구원:
          • Francisco Buendia Santiago, MD

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

아니

샘플링 방법

비확률 샘플

연구 인구

The study population consists of unselected patients presenting to the Emergency Department at Hospital Universitario Santa Lucía (Cartagena) who are evaluated by the on-call cardiologist for ischemic-profile chest pain. This represents a real-world clinical cohort in an acute setting. Patients with extreme hemodynamic instability (where an additional recording would delay critical emergency treatment) and those with baseline electrocardiogram alterations (such as prior left bundle branch block or pacemaker-mediated pacing) that preclude proper ST-segment interpretation are excluded from this population.

설명

Inclusion Criteria:

  • Patients evaluated by the on-call cardiologist for chest pain with an ischemic profile.

Exclusion Criteria:

  • Patients with extreme hemodynamic instability where the additional recording would cause an ethically unacceptable delay in their treatment.
  • Patients with a prior diagnosis of left bundle branch block or pacemaker-mediated pacing.
  • Patients who decline participation in the registry.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
개입 / 치료
일반 코호트
Recording a 9-lead ECG with a smartwatch

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Smartwatch ECG records' ability to diagnose STEMI
기간: From enrollment to the blinded analysis at the end of the recruitment
Analyze the diagnostic agreement between expert cardiologists when blindly and independently classifying the smartwatch recordings versus the standard ECG recordings as "STEMI" or "non-STEMI".
From enrollment to the blinded analysis at the end of the recruitment

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 8월 14일

기본 완료 (추정된)

2027년 2월 1일

연구 완료 (추정된)

2027년 2월 1일

연구 등록 날짜

최초 제출

2026년 8월 19일

QC 기준을 충족하는 최초 제출

2026년 8월 19일

처음 게시됨 (실제)

2026년 8월 24일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 8월 26일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 8월 24일

마지막으로 확인됨

2026년 8월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • I-AREA2_26-68_SMART-CART-AMI

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .