SMARTwatch for the Diagnosis of ST-segment Elevation Myocardial Infarction in Patients With Chest Pain (SMART-CART-AMI)
Observational and Prospective Diagnostic Validation Study of the SMARTwatch for ST-segment Elevation Myocardial Infarction in Health Area of Cartagena
The main symptom that initiates the diagnostic and therapeutic process for patients with suspected acute coronary syndrome is chest pain. Based on a standard 12-lead electrocardiogram (ECG), patients can be diagnosed with ST-segment elevation myocardial infarction (STEMI), which requires immediate medical treatment. Recently, wearable devices like smartwatches with ECG capabilities have opened new pathways for cardiac triage, but their diagnostic precision and technical viability in a real, unselected Emergency Department setting need to be confirmed.
The primary objective of this prospective, observational study is to compare the diagnostic capacity of a 9-lead ECG obtained with a smartwatch against the standard 12-lead ECG for diagnosing STEMI in patients consulting for chest pain.
During the study, patients evaluated by the on-call cardiologist for ischemic chest pain will undergo their standard care. In addition to the standard 12-lead ECG, a 9-lead ECG will be sequentially recorded using a smartwatch. This is an observational study, meaning the smartwatch recording will not cause any delay in clinical action or negatively impact the patient's standard treatment.
Specifically, the study aims to:
- Analyze the diagnostic agreement between expert cardiologists when blindly and independently classifying the smartwatch recordings versus the standard ECG recordings as "STEMI" or "non-STEMI".
- Evaluate the technical feasibility of using the smartwatch in an Emergency Department setting by assessing the percentage of unreadable records due to artifacts.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
Background and Rationale:
The clinical spectrum of acute coronary syndrome (ACS) is broad, with chest pain being the primary symptom initiating the diagnostic and therapeutic cascade. In patients with ST-segment elevation myocardial infarction (STEMI), immediate reperfusion -primarily via percutaneous coronary intervention (PCI)-is crucial. While primary PCI has significantly reduced mortality, minimizing systemic delays remains vital.
Recently, wearable devices with electrocardiographic (ECG) capabilities have emerged as potential tools for ultra-early cardiac triage. Previous research, such as the SMARTAMI study, demonstrated that a sequential 9-lead smartwatch ECG has high sensitivity and specificity for detecting STEMI. However, these prior studies often compared confirmed myocardial infarction cases with healthy, asymptomatic cohorts in highly controlled environments. There is a critical need to validate the technical feasibility, signal quality, and diagnostic accuracy of this technology in a real-world Emergency Department (ED) setting with unselected patients, where factors like diaphoresis, acute pain, and time urgency complicate the recording process.
Study Design and Clinical Procedures:
This is a prospective, observational diagnostic validation and concordance study conducted in a real-world clinical setting. Patients evaluated by the on-call cardiologist for ischemic-profile chest pain will be consecutively enrolled. The study is purely observational; obtaining the smartwatch ECG will not delay standard clinical care, and standard medical management will remain unaltered.
Following standard protocols, an analog sequential 9-lead ECG (I, II, III, V1-V6) will be recorded using a smartwatch alongside the standard 12-lead ECG.
Blinding and Data Evaluation:
A rigorous double-blind, independent analysis will be performed. The on-call cardiologists responsible for acquiring the tracings in the ED will not participate in their interpretation. Both the standard 12-lead ECGs and the smartwatch ECGs will be completely anonymized using unique alphanumeric codes. Subsequently, independent expert cardiologists will blindly evaluate the tracings, classifying them as "STEMI" or "non-STEMI" without any knowledge of the patient's clinical data or the origin of each specific recording.
Statistical Approach and Sample Size:
Based on prior literature in controlled settings reporting a 93% sensitivity, this real-world study conservatively estimates an 85% expected sensitivity due to ED-specific variables (e.g., signal noise, diaphoresis). To achieve a 10% margin of error with a 95% confidence level, a sample size of 49 confirmed STEMI positive cases is required. Consecutive recruitment will continue uninterrupted until this target is reached. Patients enrolled during this period who are ultimately diagnosed as "non-STEMI" will be retained in the database to calculate the specificity of the device.
Typ studie
Typ studie
Zápis (Odhadovaný)
Zápis
Kontakty a umístění
Studijní místa
-
-
Murcia
-
Cartagena, Murcia, Španělsko, 30202
- Nábor
- Hospital General Universitario Santa Lucía
-
Kontakt:
- Eulalia Gómez Sannicolás
- Telefonní číslo: (+34) 968 110 752
- E-mail: investigacionarea2-sms@carm.es
-
Kontakt:
- Juan A Castillo Moreno, MD, PhD
- E-mail: jacastillomo@gmail.com
-
Vrchní vyšetřovatel:
- Francisco Buendia Santiago, MD
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Patients evaluated by the on-call cardiologist for chest pain with an ischemic profile.
Exclusion Criteria:
- Patients with extreme hemodynamic instability where the additional recording would cause an ethically unacceptable delay in their treatment.
- Patients with a prior diagnosis of left bundle branch block or pacemaker-mediated pacing.
- Patients who decline participation in the registry.
Studijní plán
Jak je studie koncipována?
Detaily designu
Počet skupin / kohort
Kohorty a intervence
Skupina / kohortaSkupina / kohorta |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Obecná kohorta
|
Recording a 9-lead ECG with a smartwatch
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Smartwatch ECG records' ability to diagnose STEMI
Časové okno: From enrollment to the blinded analysis at the end of the recruitment
|
Analyze the diagnostic agreement between expert cardiologists when blindly and independently classifying the smartwatch recordings versus the standard ECG recordings as "STEMI" or "non-STEMI".
|
From enrollment to the blinded analysis at the end of the recruitment
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Publikace a užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Odhadovaný)
Primární dokončení
Dokončení studie (Odhadovaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- I-AREA2_26-68_SMART-CART-AMI
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .