Fibrin Clot Augmentation in Arthroscopic Rotator Cuff Repair
Evaluation of the Efficacy of Autologous Fibrin Clot Applied to the Repair Interface in Arthroscopic Treatment of Rotator Cuff Tears: A Prospective, Randomized, Double-Blind Controlled Trial
The aim of this study is to evaluate whether applying an autologous fibrin clot to the repair site improves tendon healing and clinical outcomes after arthroscopic rotator cuff repair. Fifty patients with rotator cuff tears requiring surgery were randomly assigned to two groups: arthroscopic repair with autologous fibrin clot augmentation or standard arthroscopic repair alone. The fibrin clot is prepared from the patient's own blood without centrifugation. Tendon healing is assessed with magnetic resonance imaging (MRI) using the Sugaya classification at 12 months, and shoulder function and pain are assessed with the ASES score, Constant score and Visual Analog Scale (VAS) preoperatively and at 3, 6 and 12 months.
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
상세 설명
Rotator cuff tears are a common cause of shoulder pain and dysfunction, and retear after surgical repair remains a significant problem. Biological augmentation strategies aim to enhance healing at the tendon-bone interface. Autologous fibrin clot is a simple, low-cost biological augment that provides a fibrin scaffold containing platelets and growth factors, and it can be prepared intraoperatively without centrifugation or commercial kits.
In this prospective, randomized, double-blind controlled trial, 50 patients aged 18-80 years with full-thickness or partial-thickness rotator cuff tears (Goutallier fatty infiltration grade 1 or 2) and an indication for surgical repair were randomly allocated in a 1:1 ratio using a computer-generated randomization sequence to either the fibrin clot group (n=25) or the control group (n=25). Patients and outcome assessors are blinded to group allocation.
In the fibrin clot group, 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms. The clot is then delivered arthroscopically to the tendon-bone repair interface. The control group undergoes the same arthroscopic rotator cuff repair without fibrin clot application. Both groups follow the same postoperative rehabilitation protocol.
The primary outcome is rotator cuff repair integrity evaluated with MRI according to the Sugaya classification at 12 months postoperatively. Secondary outcomes are ASES score, Constant score and VAS pain score, assessed preoperatively and at 3, 6 and 12 months postoperatively.
연구 유형
연구 유형
등록 (실제)
등록
단계
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Erzurum
-
Erzurum, Erzurum, 터키 (Türkiye), 25240
- Ataturk University Education and Research Hospital
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Age between 18 and 80 years
- Full-thickness or partial-thickness rotator cuff tear with an indication for arthroscopic surgical repair
- Goutallier fatty infiltration grade 1 or 2
- Written informed consent
Exclusion Criteria:
- Massive rotator cuff tear
- Advanced glenohumeral osteoarthritis
- Previous open shoulder surgery
- Serious comorbid disease (e.g., uncontrolled diabetes mellitus, advanced rheumatoid arthritis)
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 더블
팔의 수
무기와 개입
참가자 그룹 / 팔참가자 그룹 / 팔 |
개입 / 치료개입 / 치료 |
|---|---|
|
실험적: Fibrin Clot Group
Arthroscopic rotator cuff repair augmented with an autologous fibrin clot applied to the tendon-bone repair interface. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms, without centrifugation. The clot is delivered arthroscopically to the tendon-bone repair interface.
다른 이름들:
|
|
활성 비교기: Control Group
Standard arthroscopic rotator cuff repair without fibrin clot augmentation. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. |
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Rotator Cuff Repair Integrity on MRI (Sugaya Classification)
기간: 12 months postoperatively
|
Repair integrity is evaluated with magnetic resonance imaging and classified according to the Sugaya classification (Type I to V). Types I-III are considered healed and Types IV-V are considered retear. The proportion of healed repairs and the retear rate are compared between groups. |
12 months postoperatively
|
2차 결과 측정
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
American Shoulder and Elbow Surgeons (ASES) Score
기간: Preoperatively and at 3, 6 and 12 months postoperatively
|
Patient-reported shoulder pain and function score ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
기타 결과 측정
기타 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Constant-Murley Score
기간: Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder function score including pain, activities of daily living, range of motion and strength, ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
|
Visual Analog Scale (VAS) for Pain
기간: Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder pain intensity measured on a 0-10 scale, with 0 indicating no pain and 10 indicating the worst imaginable pain. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
공동 작업자 및 조사자
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (추정된)
기본 완료
연구 완료 (추정된)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
기타 연구 ID 번호
기타 연구 ID 번호
- ATAUNI-KAEK-2025-10
- 2025-10 (기타 식별자: Ataturk University Clinical Research Ethics Committee Decision Number)
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
Individual participant data will not be publicly shared due to patient confidentiality. De-identified data may be made available by the principal investigator upon reasonable request.
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .