Fibrin Clot Augmentation in Arthroscopic Rotator Cuff Repair
Evaluation of the Efficacy of Autologous Fibrin Clot Applied to the Repair Interface in Arthroscopic Treatment of Rotator Cuff Tears: A Prospective, Randomized, Double-Blind Controlled Trial
The aim of this study is to evaluate whether applying an autologous fibrin clot to the repair site improves tendon healing and clinical outcomes after arthroscopic rotator cuff repair. Fifty patients with rotator cuff tears requiring surgery were randomly assigned to two groups: arthroscopic repair with autologous fibrin clot augmentation or standard arthroscopic repair alone. The fibrin clot is prepared from the patient's own blood without centrifugation. Tendon healing is assessed with magnetic resonance imaging (MRI) using the Sugaya classification at 12 months, and shoulder function and pain are assessed with the ASES score, Constant score and Visual Analog Scale (VAS) preoperatively and at 3, 6 and 12 months.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
Rotator cuff tears are a common cause of shoulder pain and dysfunction, and retear after surgical repair remains a significant problem. Biological augmentation strategies aim to enhance healing at the tendon-bone interface. Autologous fibrin clot is a simple, low-cost biological augment that provides a fibrin scaffold containing platelets and growth factors, and it can be prepared intraoperatively without centrifugation or commercial kits.
In this prospective, randomized, double-blind controlled trial, 50 patients aged 18-80 years with full-thickness or partial-thickness rotator cuff tears (Goutallier fatty infiltration grade 1 or 2) and an indication for surgical repair were randomly allocated in a 1:1 ratio using a computer-generated randomization sequence to either the fibrin clot group (n=25) or the control group (n=25). Patients and outcome assessors are blinded to group allocation.
In the fibrin clot group, 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms. The clot is then delivered arthroscopically to the tendon-bone repair interface. The control group undergoes the same arthroscopic rotator cuff repair without fibrin clot application. Both groups follow the same postoperative rehabilitation protocol.
The primary outcome is rotator cuff repair integrity evaluated with MRI according to the Sugaya classification at 12 months postoperatively. Secondary outcomes are ASES score, Constant score and VAS pain score, assessed preoperatively and at 3, 6 and 12 months postoperatively.
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
Erzurum
-
Erzurum, Erzurum, Tyrkiet (Türkiye), 25240
- Ataturk University Education and Research Hospital
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Age between 18 and 80 years
- Full-thickness or partial-thickness rotator cuff tear with an indication for arthroscopic surgical repair
- Goutallier fatty infiltration grade 1 or 2
- Written informed consent
Exclusion Criteria:
- Massive rotator cuff tear
- Advanced glenohumeral osteoarthritis
- Previous open shoulder surgery
- Serious comorbid disease (e.g., uncontrolled diabetes mellitus, advanced rheumatoid arthritis)
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Dobbelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: Fibrin Clot Group
Arthroscopic rotator cuff repair augmented with an autologous fibrin clot applied to the tendon-bone repair interface. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms, without centrifugation. The clot is delivered arthroscopically to the tendon-bone repair interface.
Andre navne:
|
|
Aktiv komparator: Control Group
Standard arthroscopic rotator cuff repair without fibrin clot augmentation. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. |
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Rotator Cuff Repair Integrity on MRI (Sugaya Classification)
Tidsramme: 12 months postoperatively
|
Repair integrity is evaluated with magnetic resonance imaging and classified according to the Sugaya classification (Type I to V). Types I-III are considered healed and Types IV-V are considered retear. The proportion of healed repairs and the retear rate are compared between groups. |
12 months postoperatively
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
American Shoulder and Elbow Surgeons (ASES) Score
Tidsramme: Preoperatively and at 3, 6 and 12 months postoperatively
|
Patient-reported shoulder pain and function score ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
Andre resultatmål
Andre resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Constant-Murley Score
Tidsramme: Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder function score including pain, activities of daily living, range of motion and strength, ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
|
Visual Analog Scale (VAS) for Pain
Tidsramme: Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder pain intensity measured on a 0-10 scale, with 0 indicating no pain and 10 indicating the worst imaginable pain. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Publikationer og nyttige links
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Anslået)
Primær færdiggørelse
Studieafslutning (Anslået)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- ATAUNI-KAEK-2025-10
- 2025-10 (Anden identifikator: Ataturk University Clinical Research Ethics Committee Decision Number)
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
IPD-planbeskrivelse
Individual participant data will not be publicly shared due to patient confidentiality. De-identified data may be made available by the principal investigator upon reasonable request.
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .