Fibrin Clot Augmentation in Arthroscopic Rotator Cuff Repair
Evaluation of the Efficacy of Autologous Fibrin Clot Applied to the Repair Interface in Arthroscopic Treatment of Rotator Cuff Tears: A Prospective, Randomized, Double-Blind Controlled Trial
The aim of this study is to evaluate whether applying an autologous fibrin clot to the repair site improves tendon healing and clinical outcomes after arthroscopic rotator cuff repair. Fifty patients with rotator cuff tears requiring surgery were randomly assigned to two groups: arthroscopic repair with autologous fibrin clot augmentation or standard arthroscopic repair alone. The fibrin clot is prepared from the patient's own blood without centrifugation. Tendon healing is assessed with magnetic resonance imaging (MRI) using the Sugaya classification at 12 months, and shoulder function and pain are assessed with the ASES score, Constant score and Visual Analog Scale (VAS) preoperatively and at 3, 6 and 12 months.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Rotator cuff tears are a common cause of shoulder pain and dysfunction, and retear after surgical repair remains a significant problem. Biological augmentation strategies aim to enhance healing at the tendon-bone interface. Autologous fibrin clot is a simple, low-cost biological augment that provides a fibrin scaffold containing platelets and growth factors, and it can be prepared intraoperatively without centrifugation or commercial kits.
In this prospective, randomized, double-blind controlled trial, 50 patients aged 18-80 years with full-thickness or partial-thickness rotator cuff tears (Goutallier fatty infiltration grade 1 or 2) and an indication for surgical repair were randomly allocated in a 1:1 ratio using a computer-generated randomization sequence to either the fibrin clot group (n=25) or the control group (n=25). Patients and outcome assessors are blinded to group allocation.
In the fibrin clot group, 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms. The clot is then delivered arthroscopically to the tendon-bone repair interface. The control group undergoes the same arthroscopic rotator cuff repair without fibrin clot application. Both groups follow the same postoperative rehabilitation protocol.
The primary outcome is rotator cuff repair integrity evaluated with MRI according to the Sugaya classification at 12 months postoperatively. Secondary outcomes are ASES score, Constant score and VAS pain score, assessed preoperatively and at 3, 6 and 12 months postoperatively.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Erzurum
-
Erzurum, Erzurum, Turchia (Türkiye), 25240
- Ataturk University Education and Research Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Age between 18 and 80 years
- Full-thickness or partial-thickness rotator cuff tear with an indication for arthroscopic surgical repair
- Goutallier fatty infiltration grade 1 or 2
- Written informed consent
Exclusion Criteria:
- Massive rotator cuff tear
- Advanced glenohumeral osteoarthritis
- Previous open shoulder surgery
- Serious comorbid disease (e.g., uncontrolled diabetes mellitus, advanced rheumatoid arthritis)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Fibrin Clot Group
Arthroscopic rotator cuff repair augmented with an autologous fibrin clot applied to the tendon-bone repair interface. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms, without centrifugation. The clot is delivered arthroscopically to the tendon-bone repair interface.
Altri nomi:
|
|
Comparatore attivo: Control Group
Standard arthroscopic rotator cuff repair without fibrin clot augmentation. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Rotator Cuff Repair Integrity on MRI (Sugaya Classification)
Lasso di tempo: 12 months postoperatively
|
Repair integrity is evaluated with magnetic resonance imaging and classified according to the Sugaya classification (Type I to V). Types I-III are considered healed and Types IV-V are considered retear. The proportion of healed repairs and the retear rate are compared between groups. |
12 months postoperatively
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
American Shoulder and Elbow Surgeons (ASES) Score
Lasso di tempo: Preoperatively and at 3, 6 and 12 months postoperatively
|
Patient-reported shoulder pain and function score ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
Altre misure di risultato
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Constant-Murley Score
Lasso di tempo: Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder function score including pain, activities of daily living, range of motion and strength, ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
|
Visual Analog Scale (VAS) for Pain
Lasso di tempo: Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder pain intensity measured on a 0-10 scale, with 0 indicating no pain and 10 indicating the worst imaginable pain. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
Collaboratori e investigatori
Sponsor
Sponsor
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- ATAUNI-KAEK-2025-10
- 2025-10 (Altro identificatore: Ataturk University Clinical Research Ethics Committee Decision Number)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Individual participant data will not be publicly shared due to patient confidentiality. De-identified data may be made available by the principal investigator upon reasonable request.
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .