Patient Satisfaction and Prosthetic Complications of Three Different Prostheses for Rehabilitation of Atrophied Maxilla Using All-on-4 Concept
Patient Satisfaction and Prosthetic Complications of Three Different Prostheses for Rehabilitation of Atrophied Maxilla Using All-on-4 Concept: A Cross Over Study
The purpose of this cross-over clinical study is to evaluate and compare patient satisfaction and prosthetic complications associated with three different types of implant-supported prostheses used for the rehabilitation of completely edentulous atrophied maxillae following the All-on-4 treatment concept. Participants with a severely resorbed upper jaw will receive four dental implants placed according to the All-on-4 protocol. Each participant will sequentially wear three different prosthetic designs over defined follow-up periods. At the end of each period, patient satisfaction will be assessed using standardized questionnaires, and any mechanical or prosthetic complications will be recorded and compared among the three prosthetic designs.
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
- 절차: A screw-retained Computer-Aided Design and Computer-Aided Manufacturing CAD/CAM titanium framework with monolithic zirconia teeth
- 절차: A screw-retained Computer-Aided Design and Computer-Aided Manufacturing CAD/CAM polyetheretherketone framework with composite resin teeth
- 절차: A Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) titanium milled bar overdenture with polyetheretherketone (PEEK) housing and acrylic resin teeth
연구 유형
연구 유형
등록 (실제)
등록
단계
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
-
Al Mansurah, 이집트
- Faculty of Dentistry, Mansoura University
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Insufficient retention and stability of conventional maxillary dentures.
- Sufficient bone quantity and quality in the anterior maxillary region to install standard implants of at least 11 mm length and 3.7 mm diameter.
- At least 15 mm restorative space (class I) according to Ahuja and Cagna.
Exclusion Criteria:
- Metabolic disorders that affect osseointegration such as diabetes mellitus, hepatic disorders, and osteoporosis.
- History of radiation therapy in the head and neck region.
- Smoking habit.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 크로스오버 할당
- 마스킹: 없음(오픈 라벨)
팔의 수
무기와 개입
참가자 그룹 / 팔참가자 그룹 / 팔 |
개입 / 치료개입 / 치료 |
|---|---|
|
실험적: A screw retained prosthesis first with CAD/CAM titanium framework and zirconium teeth
|
A Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) titanium framework with monolithic zirconia teeth fixed prosthesis screw-retained onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design. |
|
실험적: A screw retained prosthesis first with CAD/CAM PEEK framework and composite teeth
|
A Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) polyetheretherketone (PEEK) framework with composite resin teeth fixed prosthesis screw-retained onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design. |
|
실험적: A CAD/CAM titanium milled bar overdenture with PEEK housing and acrylic teeth
|
Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) titanium milled bar overdenture with polyetheretherketone (PEEK) housing and acrylic teeth onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design. |
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Patient satisfaction
기간: 6 Months
|
Patient satisfaction using Visual Analog Scale across 12 items (retention, stability, occlusion, comfort, ease of cleaning, speech, chewing, bolus quality, appearance, handling, integration, and embarrassment) measured on a 100-mm line, where 0 mm represents 'not satisfied at all' and 100 mm represents 'completely satisfied. |
6 Months
|
|
Technical and prosthetic complications
기간: 6 Months
|
The total number and percentage of technical complications (screw loosening, screw fracture, tooth wear, material chipping, and abutment fracture) evaluated during clinical recall examinations. |
6 Months
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (실제)
기본 완료
연구 완료 (실제)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
기타 연구 ID 번호
- A011012024RP
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .