Patient Satisfaction and Prosthetic Complications of Three Different Prostheses for Rehabilitation of Atrophied Maxilla Using All-on-4 Concept
Patient Satisfaction and Prosthetic Complications of Three Different Prostheses for Rehabilitation of Atrophied Maxilla Using All-on-4 Concept: A Cross Over Study
The purpose of this cross-over clinical study is to evaluate and compare patient satisfaction and prosthetic complications associated with three different types of implant-supported prostheses used for the rehabilitation of completely edentulous atrophied maxillae following the All-on-4 treatment concept. Participants with a severely resorbed upper jaw will receive four dental implants placed according to the All-on-4 protocol. Each participant will sequentially wear three different prosthetic designs over defined follow-up periods. At the end of each period, patient satisfaction will be assessed using standardized questionnaires, and any mechanical or prosthetic complications will be recorded and compared among the three prosthetic designs.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
- Procedimiento: A screw-retained Computer-Aided Design and Computer-Aided Manufacturing CAD/CAM titanium framework with monolithic zirconia teeth
- Procedimiento: A screw-retained Computer-Aided Design and Computer-Aided Manufacturing CAD/CAM polyetheretherketone framework with composite resin teeth
- Procedimiento: A Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) titanium milled bar overdenture with polyetheretherketone (PEEK) housing and acrylic resin teeth
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Al Mansurah, Egipto
- Faculty of Dentistry, Mansoura University
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Insufficient retention and stability of conventional maxillary dentures.
- Sufficient bone quantity and quality in the anterior maxillary region to install standard implants of at least 11 mm length and 3.7 mm diameter.
- At least 15 mm restorative space (class I) according to Ahuja and Cagna.
Exclusion Criteria:
- Metabolic disorders that affect osseointegration such as diabetes mellitus, hepatic disorders, and osteoporosis.
- History of radiation therapy in the head and neck region.
- Smoking habit.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación cruzada
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: A screw retained prosthesis first with CAD/CAM titanium framework and zirconium teeth
|
A Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) titanium framework with monolithic zirconia teeth fixed prosthesis screw-retained onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design. |
|
Experimental: A screw retained prosthesis first with CAD/CAM PEEK framework and composite teeth
|
A Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) polyetheretherketone (PEEK) framework with composite resin teeth fixed prosthesis screw-retained onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design. |
|
Experimental: A CAD/CAM titanium milled bar overdenture with PEEK housing and acrylic teeth
|
Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) titanium milled bar overdenture with polyetheretherketone (PEEK) housing and acrylic teeth onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Patient satisfaction
Periodo de tiempo: 6 Months
|
Patient satisfaction using Visual Analog Scale across 12 items (retention, stability, occlusion, comfort, ease of cleaning, speech, chewing, bolus quality, appearance, handling, integration, and embarrassment) measured on a 100-mm line, where 0 mm represents 'not satisfied at all' and 100 mm represents 'completely satisfied. |
6 Months
|
|
Technical and prosthetic complications
Periodo de tiempo: 6 Months
|
The total number and percentage of technical complications (screw loosening, screw fracture, tooth wear, material chipping, and abutment fracture) evaluated during clinical recall examinations. |
6 Months
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
- Resorción ósea
- Enfermedades óseas
- Enfermedades musculoesqueléticas
- Enfermedades Estomatognáticas
- Enfermedades de la mandíbula
- Enfermedades maxilares
- Maxilar atrófico
- Salud pública
- Medio ambiente y salud pública
- Características de la población
- Ambiente
- Entorno, controlado
- Demografía
- Mediciones epidemiológicas
- Instalaciones públicas y privadas no médicas
- Características de residencia
- Alojamiento
- polyetheretherketone
Otros números de identificación del estudio
Otros números de identificación del estudio
- A011012024RP
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .