Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Patient Satisfaction and Prosthetic Complications of Three Different Prostheses for Rehabilitation of Atrophied Maxilla Using All-on-4 Concept

18 de novembro de 2026 atualizado por: Ahmed Adel Amin, Delta University for Science and Technology

Patient Satisfaction and Prosthetic Complications of Three Different Prostheses for Rehabilitation of Atrophied Maxilla Using All-on-4 Concept: A Cross Over Study

The purpose of this cross-over clinical study is to evaluate and compare patient satisfaction and prosthetic complications associated with three different types of implant-supported prostheses used for the rehabilitation of completely edentulous atrophied maxillae following the All-on-4 treatment concept. Participants with a severely resorbed upper jaw will receive four dental implants placed according to the All-on-4 protocol. Each participant will sequentially wear three different prosthetic designs over defined follow-up periods. At the end of each period, patient satisfaction will be assessed using standardized questionnaires, and any mechanical or prosthetic complications will be recorded and compared among the three prosthetic designs.

Visão geral do estudo

Status

Concluído

Condições

Intervenção / Tratamento

Tipo de estudo

Intervencional

Inscrição (Real)

18

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Al Mansurah, Egito
        • Faculty of Dentistry, Mansoura University

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

55 anos a 65 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Insufficient retention and stability of conventional maxillary dentures.
  • Sufficient bone quantity and quality in the anterior maxillary region to install standard implants of at least 11 mm length and 3.7 mm diameter.
  • At least 15 mm restorative space (class I) according to Ahuja and Cagna.

Exclusion Criteria:

  • Metabolic disorders that affect osseointegration such as diabetes mellitus, hepatic disorders, and osteoporosis.
  • History of radiation therapy in the head and neck region.
  • Smoking habit.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição cruzada
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: A screw retained prosthesis first with CAD/CAM titanium framework and zirconium teeth

A Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) titanium framework with monolithic zirconia teeth fixed prosthesis screw-retained onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design.

Experimental: A screw retained prosthesis first with CAD/CAM PEEK framework and composite teeth

A Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) polyetheretherketone (PEEK) framework with composite resin teeth fixed prosthesis screw-retained onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design.

Experimental: A CAD/CAM titanium milled bar overdenture with PEEK housing and acrylic teeth

Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) titanium milled bar overdenture with polyetheretherketone (PEEK) housing and acrylic teeth onto four multi-unit abutments placed according to the All-on-4 concept in the completely edentulous maxilla. Participants will wear this prosthesis for a period of [6 months] before crossing over to the next prosthetic design.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Patient satisfaction
Prazo: 6 Months

Patient satisfaction using Visual Analog Scale across 12 items (retention, stability, occlusion, comfort, ease of cleaning, speech, chewing, bolus quality, appearance, handling, integration, and embarrassment) measured on a 100-mm line, where 0 mm represents 'not satisfied at all' and 100 mm represents 'completely satisfied.

6 Months
Technical and prosthetic complications
Prazo: 6 Months

The total number and percentage of technical complications (screw loosening, screw fracture, tooth wear, material chipping, and abutment fracture) evaluated during clinical recall examinations.

6 Months

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

10 de dezembro de 2024

Conclusão Primária (Real)

20 de agosto de 2026

Conclusão do estudo (Real)

20 de agosto de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

12 de novembro de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

18 de novembro de 2026

Primeira postagem (Real)

19 de novembro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

19 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

18 de novembro de 2026

Última verificação

1 de novembro de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • A011012024RP

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .