A Performance Evaluation of the Enlite 3 Sensor
Studie Overzicht
Toestand
Toestand
Conditie
Conditie
Interventie / Behandeling
Interventie / Behandeling
Gedetailleerde beschrijving
Studietype
Studietype
Fase
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
California
-
Walnut Creek, California, Verenigde Staten, 94598
- Diablo Clinical Research
-
-
Washington
-
Renton, Washington, Verenigde Staten, 98057
- Rainier Clinical Research Center
-
-
Deelname Criteria
Geschiktheidscriteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Subject is 14 - 75 years of age at time of screening.
- A clinical diagnosis of type 1 or 2 diabetes for a minimum of 9 months duration as determined via medical record or source documentation by an individual qualified to make a medical diagnosis
- Adequate venous access as assessed by investigator or appropriate staff
- Subjects participating in the high and low glucose challenges must have an established insulin carbohydrate ratio(s) and insulin sensitivity ratio. (The term "established" refers to a ratio that has been previously defined and tested prior to screening visit). Subjects without established ratios may participate under observation only.
Exclusion Criteria:
- Subject will not tolerate tape adhesive in the area of Enlite 3 Sensor placement as assessed by qualified individual.
- Subject has any unresolved adverse skin condition in the area of Enlite 3 Sensors or device placement (e.g., psoriasis, rash, Staphylococcus infection)
- Subject is actively participating in an investigational study (drug or device) wherein they have received treatment from an investigational study (drug or device) in the last 2 weeks
- Subject is female and has a positive pregnancy screening test
- Females of child bearing age and who are sexually active should be excluded if they are not using a form of contraception deemed reliable by investigator.
- Subject is female and plans to become pregnant during the course of the study
- Subject has had a hypoglycemic seizure within the past 6 months.
- Subject has had hypoglycemia resulting in loss of consciousness within the past 6 months prior to screening visit.
- Subject has had an episode of diabetic ketoacidosis (DKA) within the past 6 months prior to screening visit.
- Subject has a history of a seizure disorder.
- Subject has central nervous system or cardiac disorder resulting in syncope.
- Subject has a history of myocardial infarction, unstable angina, coronary artery bypass surgery, coronary artery stenting, transient ischemic attack (TIA), cerebrovascular accident (CVA), angina, congestive heart failure, ventricular rhythm disturbances or thromboembolic disease.
- Subject has a hematocrit(Hct) lower than the normal reference range.
- Subject has a history of adrenal insufficiency
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Aantal wapens
Wapens en interventies
Deelnemersgroep / ArmDeelnemersgroep / Arm |
Interventie / BehandelingInterventie / Behandeling |
|---|---|
|
Actieve vergelijker: Group A
Subjects will be randomly assigned to 2 groups (Group A & Group B) that will determine when they will be participating in the in-clinic YSI frequent sample testing.
|
Use of Enlite 3 Sensor over 168 hours (7 days) when inserted in the arm and used with the 640G Pump in subjects aged 14-75 years who have had a diagnosis of type 1 or type 2 diabetes for at least 12 months.
|
|
Actieve vergelijker: Group B
Subjects will be randomly assigned to 2 groups (Group A & Group B) that will determine when they will be participating in the in-clinic YSI frequent sample testing.
|
Use of Enlite 3 Sensor over 168 hours (7 days) when inserted in the arm and used with the 640G Pump in subjects aged 14-75 years who have had a diagnosis of type 1 or type 2 diabetes for at least 12 months.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Enlite 3 Sensor inserted at Arm accuracy using a real time device: (640G pump) with the minimum calibration requirements (every 12 hours after the second calibration) will be evaluated.
Tijdsspanne: 1 month
|
Glucose sensor values will be compared to Yellow Spring Instruments (YSI)plasma glucose values during Frequent Sample Testing.
|
1 month
|
Medewerkers en onderzoekers
Sponsor
Sponsor
Onderzoekers
Onderzoekers
- Studie directeur: Scott Lee, MD, Medtronic Diabetes
Studie record data
Bestudeer belangrijke data
Studie start
Studie start
Primaire voltooiing (Werkelijk)
Primaire voltooiing
Studie voltooiing (Werkelijk)
Studie voltooiing
Studieregistratiedata
Eerst ingediend
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Eerst geplaatst
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update geplaatst
Laatste update ingediend die voldeed aan QC-criteria
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
Andere studie-ID-nummers
- CEP309
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .