Evaluating Percutaneous Repair Of The Atrial Septum With A Novel PFO Occluder: The PROTEA-PFO OUS Study (PROTEA-PFO OUS)
The goal of this clinical trial is to test a new heart device called P3 Occluder System in patients who have a small opening between the upper chambers of the heart (called a Patent Foramen Ovale or PFO) and have experienced a stroke that may be related to this heart opening. The main question it aims to answer is:
• Is the P3 Occluder System safe and effective for closing a PFO in patients who have had a stroke that could be related to a PFO.
Participants will:
- Undergo the procedure to implant the P3 Occluder System, if deemed appropriate.
- Visit their doctor at 1 month, 3 months, 6 months, and 1 year after the procedure for follow up exams.
- Answer a phone call from study staff at 2 years and 3 years after the procedure to answer a survey.
Studie Overzicht
Toestand
Toestand
Conditie
Conditie
Interventie / Behandeling
Interventie / Behandeling
Studietype
Studietype
Inschrijving (Geschat)
Inschrijving
Fase
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
Studiecontact
- Naam: VP, Clinical Affairs
- Telefoonnummer: 1.646.583.0352
- E-mail: clinical@recrosscardio.com
Studie Locaties
-
-
-
Belgrade, Servië
- Werving
- Institute for cardiovascular diseases ''Dedinje'', Belgrade
-
Contact:
- Dr. Valentina Balint
- E-mail: dedinje@ikvbd.com
-
-
Deelname Criteria
Geschiktheidscriteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- Patient must be ≥ 18 and ≤ 65 years of age
- Diagnosis of PFO, defined as visualization of microbubbles per TEE in the left atrium within three cardiac cycles from the right atrial opacification demonstrating right-to-left shunting at rest and/or during Valsalva release.
- Ischemic stroke, defined as acute focal neurological deficit, presumed to be due to focal ischemia and confirmed by MRI or CT to have a neuroanatomically relevant cerebral infarct.
- Modified Rankin score (mRS) ≤ 3.
- Appropriate PFO anatomy for implantation of the investigational device as evaluated and determined by independent committee.
- Patient is willing and capable of providing informed consent.
- Prior to index procedure (7-day window), persons of childbearing potential must have a negative pregnancy test.
Exclusion Criteria:
- Other identifiable causes of stroke, including but not limited to aortic arch plaques (protruding >4 mm into the lumen), large artery atherosclerotic disease proximal to the territory of the index stroke, an established cardioembolic source, small-vessel occlusive disease, or arterial dissection, presence of left atrial appendage thrombus.
- Other arteriopathy of the intracranial or extracranial vessels with >50% stenosis proximal to the territory of the index stroke.
- Intracardiac thrombus or tumor.
- Myocardial Infarction (MI) or unstable angina within the previous 180 days.
- Life expectancy < 2 years.
- Left ventricular aneurysm or akinesis.
- Moderate to severe mitral valve stenosis or severe mitral regurgitation.
- Aortic valve stenosis (mean gradient >20 mmHg) or severe regurgitation.
- Active endocarditis or other infection that may preclude implantation of the investigational device.
- Any valve vegetation or Lambl's excrescence of any left-sided valve.
- Left ventricular dilated cardiomyopathy with LVEF <35%.
- Another source of right-to-left shunts identified at baseline, including an atrial septal defect and/or fenestrated septum and pulmonary arteriovenous malformation.
- History of atrial tachycardia, atrial fibrillation or flutter, AV block, or ventricular arrhythmia requiring antiarrhythmic medication, pacemaker, or AICD.
- Severe renal failure ( Stage 4 CKD, eGFR <30) or patient requiring dialysis.
- Severe liver disease (e.g., documented cirrhosis or active hepatitis).
- Severe lung insufficiency (e.g., need for supplemental oxygen or chronic steroid medications).
- Uncontrolled hypertension, defined as sustained elevated blood pressure >140/90 mm Hg.
- Severe pulmonary artery hypertension, defined as pulmonary systolic pressure of >50mmHg.
- Uncontrolled hyperglycemia, defined as HbA1c value >8% (IFCC: >64 mmol/mol).
- Increased bleeding risk such as severe liver failure, active peptic ulcer, proliferative diabetic retinopathy, history of severe bleeding (e.g.: gastrointestinal bleeding, macroscopic hematuria, intraocular bleeding, intracranial or cerebral hemorrhage), or other history of bleeding or coagulopathy.
- Known hypercoagulable state that would require full anticoagulation. Minimum testing to include lupus anticoagulant, anticardiolipin antibodies, beta-2-glycoprotein, homocysteine.
- Subjects contraindicated for aspirin or clopidogrel.
- Subjects not able to discontinue anticoagulation for indications other than then index stroke.
- Any disorder in the investigator's opinion that could interfere with compliance of safety evaluation or require premature discontinuation of antiplatelet regime post-implantation, as well as any severe concurrent illness that would limit life expectancy (e.g., malignancies).
- Currently an active subject in an investigational drug or device study that could confound the results of this study.
- Any significant valve dysfunction that contraindicates PFO closure or increased pulmonary vascular resistance/severe pulmonary hypertension.
- Contraindication for transesophageal echocardiography (TEE) or intracardiac echocardiography (ICE).
- Any prior percutaneous cardiovascular intervention for AF ablation.
- Known nickel allergy that, in the opinion of the investigator, poses a safety risk with regards to participation in the trial.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Toestel Haalbaarheid
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Aantal wapens
Wapens en interventies
Deelnemersgroep / ArmDeelnemersgroep / Arm |
Interventie / BehandelingInterventie / Behandeling |
|---|---|
|
Experimenteel: Recross P3 Occluder (P3O) -systeem
De Recross P3-occluder (P3O) wordt ontwikkeld met het oog op transcatheterafsluiting van een octrooi foramen ovale (PFO) om het risico op terugkerende ischemische beroerte te verminderen bij patiënten met PFO-geassocieerde beroerte.
|
De Recross P3-occluder (P3O) wordt ontwikkeld met het oog op transcatheterafsluiting van een octrooi foramen ovale (PFO) om het risico op terugkerende ischemische beroerte te verminderen bij patiënten met PFO-geassocieerde beroerte.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Effective PFO Closure
Tijdsspanne: 6 months
|
Effective PFO Closure, at index procedure and at 6 months as measured by TEE, as adjudicated.
|
6 months
|
|
Adverse Cardiovascular Events
Tijdsspanne: 30 days
|
Occurrence of significant adverse events including cardiac death, myocardial infarction, and stroke within 30 days post-procedure
|
30 days
|
Secundaire uitkomstmaten
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Rate of device-related or procedure-related Serious Adverse Events (SAEs)
Tijdsspanne: 30 days; 6 months
|
Rate of device-related or procedure-related Serious Adverse Events (SAEs) at 30 days.
Rate of device-related or procedure-related Serious Adverse Events (SAEs) at 6 months.
|
30 days; 6 months
|
|
Correct device position
Tijdsspanne: 6 months
|
Correct device position as assessed at 6 months on echocardiography, assessed by TTE or TEE.
|
6 months
|
Medewerkers en onderzoekers
Sponsor
Sponsor
Medewerkers
Medewerkers
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Studie start
Primaire voltooiing (Geschat)
Primaire voltooiing
Studie voltooiing (Geschat)
Studie voltooiing
Studieregistratiedata
Eerst ingediend
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Eerst geplaatst
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update geplaatst
Laatste update ingediend die voldeed aan QC-criteria
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
- Cerebrovasculaire aandoeningen
- Hersenziekten
- Ziekten van het centrale zenuwstelsel
- Ziekten van het zenuwstelsel
- Vaatziekten
- Hart-en vaatziekten
- Hartziekten
- Aangeboren afwijkingen
- Cardiovasculaire afwijkingen
- Hartafwijkingen, aangeboren
- Hartinfarct
- Hartseptumdefecten, atrium
- Hartseptumdefecten
- Aangeboren, erfelijke en neonatale ziekten en afwijkingen
- Ischemische beroerte
- Foramen ovale, patent
- Therapeutica
- Drugstherapie
- Geneesmiddelenafgiftesystemen
Andere studie-ID-nummers
Andere studie-ID-nummers
- PL5003
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .