Non-Invasive Cerenkov Luminescence Imaging of Lymphoma, Leukemia and Metastatic Lymph Nodes
The purpose of this study is to see if a new way of imaging called the Cerenkov luminescence or effect that is used with a standard clinical PET/CT and/or investigation scans can be done in order to capture tumor sizes. The investigators believe endoscopies and surgical procedures could benefit from this type of imaging in the future. The Cerenkov imaging could be used as a guide for surgical resections.
The purpose of this study is to use the Cerenkov light from FDG, Iodine-131 tracer sand/or other investigational tracers to image tumors and its sizes in the head, neck, breast, axillary and pelvic regions with a highly sensitive camera. The investigators will be trying to see if we can get another picture of the tumor using the Cerenkov light as part of the standard clinical scan or therapy.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
New York
-
New York, New York, Verenigde Staten, 10065
- Memorial Sloan-Kettering Cancer Center
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Participant is 18 years of age or older.
- Participant is scheduled for standard clinical and/or investigational PET/CT scan or 131I therapy within the Nuclear Medicine Service at Main Hospital.
- Patients must have had pathologic lymph node metastases in the neck, axillary or inguinal area (do not need to be biopsy proven) from either leukemias, lymphomas: , Head and Neck cancers (e.g. tonsillar, nasopharynx, tongue carcinoma, breast cancer or melanoma;or lymphoma or tonsillar or squamous cell carcinoma with metastases in the neck region for PET/CT imaging, or thyroid cancer for thyroid ablation therapy. Any other more infrequent cancer metastasizing with nodal metastasis in the neck, axilla and inguinal regions to cervical lymph nodes is eligible as well as the primary goal is to image pathological (i.e. hypermetabolic) lymph nodes.
- Patients with hypermetabolic activity and uptake in the neck,axilla, breast and inguinal region on scan, defined visually as significant lesion suspicious for malignancy by a nuclear medicine physician or trainee. (We will include a subset of patients with normal lymph nodes during screening. This subset of patients will be imaged as a negative control for this study.)
Exclusion Criteria:
- Patients imaged for Cerenkov luminescence are going to be required to be in a darkened enclosure for at least 10 minutes and sit still during image acquisition, potentially covered by a dark cloth in case that the ambient light level remains too high for the ultra-sensitive camera. Any conditions that would prevent this will exclude the patients.
- There are any other past medical, physiological or demographic concerns. This includes any patients with skin blemishes that are present at the dermis over the tumor, as these are of particular interest for use of this technique.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
---|---|
pts receiving a PET/CT scan with Metastatic LNs
This study seeks to optically image the Cerenkov emissions from the PET tracer 18F-FDG and the radiotherapeutic 131I in a cohort of patients with primary tumor sites and from pathologic lymph nodes after routine 18F-FDG PET 31I radiotherapy and/or investigational study scans.
We will include a subset of patients with normal lymph nodes during screening.
This subset of patients will be imaged as a negative control for this study.
|
We will image (i) patients who are receiving a PET/CT scan for tumors in the head / neck region and (ii) patients with thyroid cancer after 131I radioablation.
Two scans will be completed per patient, one of the primary tumors, as well as a 'background' scan of the contralateral side or, if tumor is there as well, of the forearm.
The device to be used is an intensified charge-coupled device camera (Stanford Photonics, Palo Alto, CA) connected to a laptop PC.
The camera will use a Quartz high-UV transmission 50 mm 0.8f lens.
The Imaging device will be placed approximately 5 cm from the area of the patient to be imaged.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
feasibility of clinical Cerenkov imaging
Tijdsspanne: 2 years
|
is to assess the feasibility of clinical Cerenkov luminescence imaging using current clinical radiotracers (18F-FDG and 131I) and a highly sensitive camera.
|
2 years
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
Correlate Cerenkov imaging
Tijdsspanne: 2 years
|
signal with uptake of the radiotracer.
Cerenkov images will be correlated with images obtained from standard clinical PET/CT and scintigraphy.
|
2 years
|
Medewerkers en onderzoekers
Medewerkers
Onderzoekers
- Hoofdonderzoeker: Jan Grimm, MD, PhD, Memorial Sloan Kettering Cancer Center
Publicaties en nuttige links
Nuttige links
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 12-050
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .