- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT03583970
Veno-arterial Extracorporeal Membrane Oxygenation Prior to Left Ventricular Assist Device Implantation. (LVAD-ECMO)
Veno-arterial Extracorporeal Membrane Oxygenation Support Prior to Left Ventricular Assist Device Implantation : Initial Patients Characteristics and 6 Month Follow-up, a Retrospective Study (2013-2017) (LVAD-ECMO)
Cardiogenic shock is an uncommun pathology with a high mortatily rate around 45%. Veno arterial extracorporeal membrane oxygenation (VA-ECMO) is a temporary extracorporeal assist device which restore an adequate blood flow when a circulatory failure occures. VA-ECMO main indication is refractory cardiogenic shock whatever the etiology. Current medical care of terminal cardiac failure includes use of long-term mechanical circulatory support devices (MCSD) such as Left Ventricular Assist Device (LVAD). LVAD therapy may lead to heart transplant (bridge to transplantation), to recovery (bridge to recovery) or to permanent implantation (destination therapy). Few patients with refractory cardiogenic shock treated with VA-ECMO may secondarily need a long term MCSD with LVAD.
LVAD long-term heart assist showed interesting survival rate when implantation occured (71% after 2 years follow-up and 45% after 4 years follow-up) out of acute heart failure situation. There are only few datas concerning LVAD implantion during refractory cardiogenic shock, with a mortality between 20 to 50% in different studies.
In this way, in comparaison of current few datas on the subject of LVAD implantation under VA-ECMO, the investigators (15 french-speacking centers) would retrospectively describe a large population.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Verwacht)
Contacten en locaties
Studie Locaties
-
-
-
Nancy, Frankrijk, 54000
- Werving
- CHRU NANCY
-
Contact:
- Caroline FRITZ, MD
- Telefoonnummer: +33383157379
- E-mail: c.fritz@chru-nancy.fr
-
Contact:
- Bruno LEVY, MD-PhD
- Telefoonnummer: +33383154469
- E-mail: b.levy@chru-nancy.fr
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Veno-arterial ExtraCorporeal Membrane Oxygenation prior to left ventricular assist device implantation.
- Veno-arterial ExtraCorporeal Membrane Oxygenation at the left ventricular assist device implantation operative time
Exclusion Criteria:
- ExtraCorporeal Membrane Oxygenation weaving before left ventricular assist device implantation.
- Cardiac assist devices other than Veno-arterial ExtraCorporeal Membrane Oxygenation
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
6-month hospital discharge after LVAD implantation
Tijdsspanne: 6 month after LVAD implantation
|
6-month hospital discharge after LVAD implantation
|
6 month after LVAD implantation
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Mortality rate
Tijdsspanne: up to six month after LVAD implantation
|
Six month mortality rate after LVAD implantation
|
up to six month after LVAD implantation
|
|
ICU discharge
Tijdsspanne: up to six month after LVAD implantation
|
Days until ICU discharge after LVAD implantation
|
up to six month after LVAD implantation
|
|
Quality of life
Tijdsspanne: up to six month after LVAD implantation
|
ADL and IADL scale
|
up to six month after LVAD implantation
|
Andere uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Hemodynamic Failure
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
Amount of Norepinephrine infused
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Cardiogenic failure
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
Amount of inotrope infused
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Cardio-circulatory failure
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
ECLS assistance
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Renal failure
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
Worst KDIGO stage
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Hepatic failure
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
Worst values of PT/bilirubin/ AST and ALT
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Thrombosis complication
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
Thrombosis event
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Haemorragic complication
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
Haemorragic event
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Respiratory failure
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
Ventilation assistance
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Neurological failure
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
neurological sequelae
|
Before LVAD implantation - up to 28 day - up to 6 month
|
|
Infection complication
Tijdsspanne: Before LVAD implantation - up to 28 day - up to 6 month
|
documented infection
|
Before LVAD implantation - up to 28 day - up to 6 month
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Studie stoel: Bruno Levy, MD-PhD, CHRU NANCY
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Verwacht)
Studie voltooiing (Verwacht)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- PSS2017/LVADECMO-FRITZ/YB
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .