Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Veno-arterial Extracorporeal Membrane Oxygenation Prior to Left Ventricular Assist Device Implantation. (LVAD-ECMO)

16 de julio de 2018 actualizado por: Caroline FRITZ, Central Hospital, Nancy, France

Veno-arterial Extracorporeal Membrane Oxygenation Support Prior to Left Ventricular Assist Device Implantation : Initial Patients Characteristics and 6 Month Follow-up, a Retrospective Study (2013-2017) (LVAD-ECMO)

Cardiogenic shock is an uncommun pathology with a high mortatily rate around 45%. Veno arterial extracorporeal membrane oxygenation (VA-ECMO) is a temporary extracorporeal assist device which restore an adequate blood flow when a circulatory failure occures. VA-ECMO main indication is refractory cardiogenic shock whatever the etiology. Current medical care of terminal cardiac failure includes use of long-term mechanical circulatory support devices (MCSD) such as Left Ventricular Assist Device (LVAD). LVAD therapy may lead to heart transplant (bridge to transplantation), to recovery (bridge to recovery) or to permanent implantation (destination therapy). Few patients with refractory cardiogenic shock treated with VA-ECMO may secondarily need a long term MCSD with LVAD.

LVAD long-term heart assist showed interesting survival rate when implantation occured (71% after 2 years follow-up and 45% after 4 years follow-up) out of acute heart failure situation. There are only few datas concerning LVAD implantion during refractory cardiogenic shock, with a mortality between 20 to 50% in different studies.

In this way, in comparaison of current few datas on the subject of LVAD implantation under VA-ECMO, the investigators (15 french-speacking centers) would retrospectively describe a large population.

Descripción general del estudio

Tipo de estudio

De observación

Inscripción (Anticipado)

100

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Nancy, Francia, 54000
        • Reclutamiento
        • CHRU NANCY
        • Contacto:
        • Contacto:

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

All patients between 01.01.2013 and 31.12.2017 in the participating centers implanted with LVAD during VA-ECMO therapy for refractory cardiogenic shock.

Descripción

Inclusion Criteria:

  • Veno-arterial ExtraCorporeal Membrane Oxygenation prior to left ventricular assist device implantation.
  • Veno-arterial ExtraCorporeal Membrane Oxygenation at the left ventricular assist device implantation operative time

Exclusion Criteria:

  • ExtraCorporeal Membrane Oxygenation weaving before left ventricular assist device implantation.
  • Cardiac assist devices other than Veno-arterial ExtraCorporeal Membrane Oxygenation

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
6-month hospital discharge after LVAD implantation
Periodo de tiempo: 6 month after LVAD implantation
6-month hospital discharge after LVAD implantation
6 month after LVAD implantation

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Mortality rate
Periodo de tiempo: up to six month after LVAD implantation
Six month mortality rate after LVAD implantation
up to six month after LVAD implantation
ICU discharge
Periodo de tiempo: up to six month after LVAD implantation
Days until ICU discharge after LVAD implantation
up to six month after LVAD implantation
Quality of life
Periodo de tiempo: up to six month after LVAD implantation
ADL and IADL scale
up to six month after LVAD implantation

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
Hemodynamic Failure
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
Amount of Norepinephrine infused
Before LVAD implantation - up to 28 day - up to 6 month
Cardiogenic failure
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
Amount of inotrope infused
Before LVAD implantation - up to 28 day - up to 6 month
Cardio-circulatory failure
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
ECLS assistance
Before LVAD implantation - up to 28 day - up to 6 month
Renal failure
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
Worst KDIGO stage
Before LVAD implantation - up to 28 day - up to 6 month
Hepatic failure
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
Worst values of PT/bilirubin/ AST and ALT
Before LVAD implantation - up to 28 day - up to 6 month
Thrombosis complication
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
Thrombosis event
Before LVAD implantation - up to 28 day - up to 6 month
Haemorragic complication
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
Haemorragic event
Before LVAD implantation - up to 28 day - up to 6 month
Respiratory failure
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
Ventilation assistance
Before LVAD implantation - up to 28 day - up to 6 month
Neurological failure
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
neurological sequelae
Before LVAD implantation - up to 28 day - up to 6 month
Infection complication
Periodo de tiempo: Before LVAD implantation - up to 28 day - up to 6 month
documented infection
Before LVAD implantation - up to 28 day - up to 6 month

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Silla de estudio: Bruno Levy, MD-PhD, CHRU NANCY

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

5 de julio de 2018

Finalización primaria (Anticipado)

1 de junio de 2019

Finalización del estudio (Anticipado)

1 de diciembre de 2020

Fechas de registro del estudio

Enviado por primera vez

6 de junio de 2018

Primero enviado que cumplió con los criterios de control de calidad

28 de junio de 2018

Publicado por primera vez (Actual)

12 de julio de 2018

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

17 de julio de 2018

Última actualización enviada que cumplió con los criterios de control de calidad

16 de julio de 2018

Última verificación

1 de julio de 2018

Más información

Términos relacionados con este estudio

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir