- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT04284644
Co-induction Technique Compared to Standard Inhalational and Intravenous Induction Techniques
A Novel Co-induction Technique Compared to Standard Inhalational and Intravenous Induction Techniques: a Prospective Randomized Control Study
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
Co-induction technique refers to the use of a combination of medications to reach the desired therapeutic target. This technique is considered an approach that can be of a great benefit to patients with chronic medical illnesses and those who have moderate to high risk for general anaesthesia.
In the present study, the investigators examined the safety of a novel co-induction approach that relied on a simple timing and dosing alterations to the classical approaches of inhalational sevoflurane and propofol induction. The significance of this study is to find a reliable safe alternative method of induction that can provide optimal parameters,when compared to the classical methods of induction. The investigators evaluated the time needed for laryngeal mask airway (LMA) insertion, number of LMA insertion trials, succession of LMA insertion, adverse events related to the airway, respiratory and cardiovascular systems, haemodynamic stability and satisfaction scores of enrolled patients.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Amman, Jordanië, 11942
- Jordan University Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- patients with Age ≥ 65 years.
- American Society of Anaesthesiologists' (ASA) score II or III.
- minimally invasive endoscopic urological procedures.
Exclusion Criteria:
- patient refusal.
- Age < 65 years.
- family history of malignant hyperthermia.
- prolonged surgery that needed intubation.
- body mass index (BMI) > 35 kg/m2.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Preventie
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Group P
Patient received a dose of 1.5 mg/kg of Propofol slowly over 2 minutes for induction.
|
Patients were given 1.5 mcg/Kg of fentanyl intravenously.
two minutes after the fentanyl dose, a dose of 1.5 mg/kg of propofol slowly over 2 minutes.
|
|
Experimenteel: Group S
Patient received 8% sevoflurane through sealed plastic facemask at 8 L/min flow of oxygen.
|
Patients were given 1.5 mcg/Kg of fentanyl intravenously.
two minutes after the fentanyl dose, patient received 8% inhalational sevoflurane through sealed plastic face mask at 8 L/min flow of oxygen.
|
|
Experimenteel: Group C
Patient received 4% sevoflurane through sealed plastic facemask at 8 L/min flow of oxygen for 2 minutes, followed by a dose of 0.75 mg/kg of propofol given slowly.
|
Patients were given 1.5 mcg/Kg of fentanyl intravenously.
two minutes after the fentanyl dose, patient received 4% sevoflurane through sealed plastic face mask at 8 L/min flow of oxygen for 2 minutes, followed by a dose of 0.75 mg/kg of propofol given slowly.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Intraoperative respiratory adverse events
Tijdsspanne: 8 months
|
The investigators recorded the occurrence of transient apnea intraoperatively, in addition to laryngeal spasm, coughing, gagging and increased salivation.
The study chart included the documentation these common adverse events, the timing of occurrence, and the intervention required to manage these events.
|
8 months
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Time for successful laryngeal mask airway insertion
Tijdsspanne: 8 months
|
The investigators assessed the time needed for LMA insertion.
The timer was started upon giving the fentanyl, recording the time till successful insertion of laryngeal mask airway.
|
8 months
|
|
Blood pressure stability
Tijdsspanne: 8 months
|
The investigators recorded patients' blood pressure readings throughout the induction procedure.
|
8 months
|
|
Heart rate stability
Tijdsspanne: 8 months
|
The investigators recorded patients' heart rate throughout the induction procedure.
|
8 months
|
|
Changes in oxygen saturation
Tijdsspanne: 8 months
|
The investigators recorded patients' oxygen saturation throughout the induction procedure.
|
8 months
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 10/2016/4597
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .