Origin of Premature Atrial Beats Induced by Simulated Obstructive Sleep Apnea
Electroanatomic Origin of Premature Atrial Beats in Patients With Paroxysmal Atrial Fibrillation Induced by Intra-thoracic Pressure Swings Simulating Obstructive Sleep Apnea
Studieoversikt
Status
Status
Forhold
Forhold
Intervensjon / Behandling
Intervensjon / Behandling
Studietype
Studietype
Registrering (Faktiske)
Registrering
Fase
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
Canton of Zurich
-
Zurich, Canton of Zurich, Sveits, 8091
- University Hospital of Zurich
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- History of ECG-documented paroxysmal atrial fibrillation within the last 12 months and currently in sinus rhythm
- Scheduled for circumferential pulmonary venous isolation treatment
- 18 to 75 years of age
- Signed informed consent
Exclusion Criteria:
- Treated with class III anti-arrhythmic agents (at the moment of pulmonary venous isolation)
- Treated for obstructive sleep apnea
- Previous catheter ablation in the pulmonary veins or left atrium
- Severe structural heart disease
- Mental or physical disability precluding informed consent or compliance with the protocol
- Enrolled in another study that would confound the results of this trial
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Grunnvitenskap
- Tildeling: Ikke-randomisert
- Intervensjonsmodell: Enkeltgruppeoppdrag
- Masking: Ingen (Open Label)
Antall våpen
Våpen og intervensjoner
Deltakergruppe / ArmDeltakergruppe / Arm |
Intervensjon / BehandlingIntervensjon / Behandling |
|---|---|
|
Annen: Pulmonary vein isolation
Intra-thoracic pressure swings induced by breathing manoeuvres during standard catheter-ablation procedure.
Catheter-based electrical mapping and pressure in the left atrium and pulmonary veins during standard catheter-ablation procedure.
Only patients with an apnea-hypopnea index > 5/h and documented premature atrial beats during the Mueller manoeuvre will be eligible for the catheter-based electrical mapping.
Follow-up after 1 year for atrial fibrillation recurrence.
|
The MM will be carried out during a elective standard pulmonary vein isolation procedure.
The MM will be performed using an occluded mouthpiece with a small air leak to prevent complete closure of the glottis during inspiration and thus assure negative pressure throughout the entire airway.
After expiration, inspiration with a target negative intrathoracic pressure of -40mmHg will be carried out against the mouthpiece.
|
|
Ingen inngripen: No intevention
Intra-thoracic pressure swings induced by breathing manoeuvres during ECG-monitoring.
Only patients with an apnea-hypopnea index < 5/h and no premature atrial beats during the Mueller manoeuvre will be assigned to the no intervention arm.
|
Hva måler studien?
Primære resultatmål
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Electroanatomical origin of premature atrial beats
Tidsramme: Participants will be followed for the duration of pulmonary vein isolation, an expected average of 3 hours
|
(Loop-)Catheter-based origin detection in patients with apnea-hypopnea index > 5/h in home sleep study and documented premature atrial beats during three time points: baseline (normal breathing), inspiration through a threshold load device, and the Mueller Manoeuvre (MM).
Origins will be quantitatively marked at a left atrial map.
|
Participants will be followed for the duration of pulmonary vein isolation, an expected average of 3 hours
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Catheter-based pressure in the left atrium and pulmonary veins during intra-thoracic pressure changes
Tidsramme: Participants will be followed for the duration of pulmonary vein isolation, an expected average of 3 hours
|
Catheter-based left atrial pressure measurement in patients with apnea-hypopnea index > 5/h in home sleep study and documented premature atrial beats during three time points: baseline (normal breathing), inspiration through a threshold load device, and the Mueller Manoeuvre.
Changes in left atrial pressure will be recorded in cmH2O.
|
Participants will be followed for the duration of pulmonary vein isolation, an expected average of 3 hours
|
Samarbeidspartnere og etterforskere
Sponsor
Sponsor
Etterforskere
Etterforskere
- Hovedetterforsker: Malcolm Kohler, MD, Prof, University of Zurich
Studierekorddatoer
Studer hoveddatoer
Studiestart
Studiestart
Primær fullføring (Faktiske)
Primær fullføring
Studiet fullført (Faktiske)
Studiet fullført
Datoer for studieregistrering
Først innsendt
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Anslag)
Først lagt ut
Oppdateringer av studieposter
Sist oppdatering lagt ut (Anslag)
Sist oppdatering lagt ut
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Ytterligere relevante MeSH-vilkår
- Patologiske prosesser
- Hjertesykdommer
- Kardiovaskulære sykdommer
- Sykdommer i nervesystemet
- Sykdommer i luftveiene
- Respirasjonsforstyrrelser
- Søvnforstyrrelser, iboende
- Dyssomnier
- Søvnvåkenforstyrrelser
- Tegn og symptomer, luftveier
- Arytmier, hjerte
- Sykdom i hjertets ledningssystem
- Graviditetskomplikasjoner
- Obstetriske arbeidskomplikasjoner
- Obstetrisk arbeid, prematur
- Hjertekomplekser, for tidlig
- Søvnapné syndromer
- Søvnapné, obstruktiv
- Apné
- Atrieflimmer
- For tidlig fødsel
- Atrielle premature komplekser
Andre studie-ID-numre
Andre studie-ID-numre
- KEK-ZH-Nr. 2014-0203
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .