Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

ORASIS in Breast Reconstruction

29. juni 2026 oppdatert av: Duke University

ORASIS and Microsurgical Anastomosis Outcomes in DIEP Flap Breast Reconstruction: A Crossover Randomized Controlled Trial

The purpose of this study is to assess the use of ORASIS during microsurgical anastomosis formation in Deep Inferior Epigastric Perforator (DIEP) flap breast reconstruction and its potential effects on surgical precision, surgeon efficiency, and anastomosis outcomes. The investigators hypothesize that the use of ORASIS will decrease the amount of time needed to perform microsurgical anastomoses, reduce interruptions for irrigation and suction, and increase the quality of anastomoses in DIEP flap breast reconstruction.

Studieoversikt

Status

Har ikke rekruttert ennå

Forhold

Intervensjon / Behandling

Studietype

Intervensjonell

Registrering (Antatt)

30

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Studer Kontakt Backup

Studiesteder

    • North Carolina
      • Durham, North Carolina, Forente stater, 27710
        • Duke University Medical Center
        • Ta kontakt med:
      • Raleigh, North Carolina, Forente stater, 27609
        • Duke Raleigh Hospital
        • Ta kontakt med:

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Nei

Beskrivelse

Inclusion:

  • Female Deep Inferior Epigastric Perforator (DIEP) flap breast reconstruction patients who have received a prior mastectomy (either unilateral or bilateral) on the breast undergoing reconstruction
  • Patients who received mastectomies for oncologic or prophylactic indications
  • Patients receiving either immediate or delayed DIEP flap breast reconstruction
  • Age 18 or older at the time of patient consent and DIEP flap surgery

Exclusion:

  • History of any prior tissue expander placement or breast reconstruction on the breast undergoing DIEP flap reconstruction
  • Patients receiving DIEP flap breast reconstruction for indications other than oncologic or prophylactic post-mastectomy breast reconstruction
  • Under the age of 18 at the time of patient consent or DIEP flap surgery

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: Randomisert
  • Intervensjonsmodell: Crossover-oppdrag
  • Masking: Enkelt

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Ingen inngripen: Control Arm
In the control arm, surgeons will perform two microsurgical anastomoses without the use of ORASIS in either bilateral or unilateral Deep Inferior Epigastric Perforator (DIEP) flap reconstruction. If bilateral DIEP flap reconstruction is performed in the control arm, only the first microsurgical anastomosis for each bilateral DIEP flap reconstruction will be assessed. In both study arms, surgeons will perform end-to-end anastomosis using current standard-of-care techniques. This will include the formation of anastomoses between the deep inferior epigastric artery (DIEA) perforators and internal mammary artery (IMA) in the antegrade direction of blood flow using 8-0 nylon sutures, as well as the deep inferior epigastric vein (DIEV) perforators and internal mammary vein (IMV).
Eksperimentell: ORASIS Arm
In the ORASIS arm, surgeons will perform two microsurgical anastomoses with the use of ORASIS in either bilateral or unilateral Deep Inferior Epigastric Perforator (DIEP) flap reconstruction. If bilateral DIEP flap reconstruction is performed in the treatment arm, ORASIS will only be used in the first microsurgical anastomosis performed in each bilateral DIEP flap reconstruction; only the breast reconstructed with the use of ORASIS will be assessed. In both study arms, surgeons will perform end-to-end anastomosis using current standard-of-care techniques. This will include the formation of anastomoses between the deep inferior epigastric artery (DIEA) and internal mammary artery (IMA) in the antegrade direction of blood flow using 8-0 nylon sutures, as well as the deep inferior epigastric vein (DIEV) perforators and internal mammary vein (IMV).
The study intervention is the use of the ORASIS device during Deep Inferior Epigastric Perforator (DIEP) flap breast reconstruction. ORASIS is a dual irrigation and suction device that can be placed in the surgical field during the formation of microsurgical anastomoses. The device was previously registered with the Food and Drug Administration (FDA) under registration number 878.4200; the device is currently not registered with the FDA as it is pending renewal. The device is manufactured by a partner company (Spectroplast/Ricoh UK) with compliance to international quality standards. The manufacturer has successfully implemented the ISO 9001 Quality Management System across operational areas following a comprehensive audit process that supports compliance with FDA Current Good Manufacturing Practice (cGMP) requirements (21 CFR Part 820) for Class I medical devices. Spectroplast/Ricoh UK is certified under FDA ISO 10993 standards for biological evaluation of medical devices.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Mean anastomosis time (minutes)
Tidsramme: From first suture placement to anastomosis completion
Total anastomosis time will be defined as the number of minutes from first suture placement to anastomosis completion.
From first suture placement to anastomosis completion
Mean ischemia time (minutes)
Tidsramme: From pedicle transection to anastomosis completion
Total ischemia time will be defined as the number of minutes from flap division to flap reperfusion.
From pedicle transection to anastomosis completion

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Mean number of interruptions per procedure
Tidsramme: From beginning of microsurgical anastomosis to end of microsurgical anastomosis
Interruptions will be defined as instances where the surgeon pauses for suction/irrigation in the control arm vs. automatic suction/irrigation in the ORASIS arm.
From beginning of microsurgical anastomosis to end of microsurgical anastomosis
Surgeon Survey
Tidsramme: Within 1 month after conclusion of DIEP flap surgery procedure
A post-procedure survey (Likert scale) will be administered after each procedure assessing ease of use, surgeon perception of precision, and overall satisfaction with the ORASIS device.
Within 1 month after conclusion of DIEP flap surgery procedure
Incidence of postoperative complications 0-48 hours after procedure
Tidsramme: Within 48 hours after DIEP flap surgery
Notable complications include flap failure, re-operation/take-back and wound dehiscence, seroma, hematoma, and surgical site infection.
Within 48 hours after DIEP flap surgery
Mean NASA-TLX (Task Load Index) score
Tidsramme: From beginning of microsurgical anastomosis to end of microsurgical anastomosis
The NASA Task Load Index (NASA-TLX) is a validated tool to measure cognitive and physical workload for surgeons, reported as a score between 0 to 100.
From beginning of microsurgical anastomosis to end of microsurgical anastomosis
Mean Surgical Assessment Metric Scale (SAMS) overall scores
Tidsramme: From beginning of microsurgical anastomosis to end of microsurgical anastomosis
The Surgical Assessment Metric Scale (SAMS) is a validated tool that assesses proficiency across key technical metrics such as suture placement, knot quality, and overall flow of the procedure on a scale of 1-5. Performed anastomoses will be recorded by the digital microscope, and the quality and precision of the anastomosis will be assessed by a blinded rater using the previously validated SAMS score checklist.
From beginning of microsurgical anastomosis to end of microsurgical anastomosis

Andre resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Number of surgeons per case
Tidsramme: During the entirety of the DIEP flap procedure
Number of surgeons per case, stratified by level of training (i.e. 1 vs 2 microsurgeons required +/- residents). For example, allowing a microsurgeon to perform the anastomosis alone as opposed to a co-surgeon case would reduce operative costs.
During the entirety of the DIEP flap procedure
Estimated cost difference per case (economic impact metrics)
Tidsramme: During the entirety of the DIEP flap procedure
Based on average operating room (OR) time cost for plastic surgery procedures at Duke (dollars per minute).
During the entirety of the DIEP flap procedure

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Sponsor

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

1. desember 2026

Primær fullføring (Antatt)

1. desember 2027

Studiet fullført (Antatt)

1. desember 2027

Datoer for studieregistrering

Først innsendt

22. juni 2026

Først innsendt som oppfylte QC-kriteriene

22. juni 2026

Først lagt ut (Faktiske)

26. juni 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

1. juli 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

29. juni 2026

Sist bekreftet

1. juni 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • Pro00118006

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

IPD-planbeskrivelse

Confidentiality of subject data will be ensured by de-identification of subject data. During data collection, subject identifiers and relevant data elements will be recorded in the database. Then, study-specific identification numbers will be assigned to each subject. Prior to dissemination of any information in this database beyond the DUMC's secure servers or firewall, all identifiers will be stripped from the database and data will only be referenced by the study-specific identification numbers.

The adequacy of the Duke Research Data Lifecycle will be evaluated and approved by the Surgery CRU and IT personnel prior to study conduct. Any publications or presentations that result from this research will not identify any subjects individually and will present data in aggregate form only. Data collected as part of this study will not be submitted to the FDA; data collected will only be used for publication as part of an assessment of device efficacy.

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Ja

produkt produsert i og eksportert fra USA

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .