Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Impact of Stepwise Pressure-Increasing NC Balloon Post-Dilation on Stent Expansion (SPND)

28. september 2026 oppdatert av: Mingyou Zhang, Jilin University

This is a prospective, single-center, single-arm exploratory observational study aiming to evaluate the impact of stepwise pressure-increasing non-compliant (NC) balloon post-dilation on stent expansion rate in patients undergoing single-stent implantation for coronary artery stenosis, with stent sizing guided by intravascular ultrasound-external elastic membrane (IVUS-EEM) measurement.

A total of 150 eligible patients will be enrolled at The First Hospital of Jilin University. All participants will receive standard single-stent implantation followed by multi-stage stepwise pressure-increasing NC balloon post-dilation under IVUS monitoring. The post-dilation protocol includes sequential inflation at nominal pressure, rated burst pressure, and 24 atm, with IVUS assessment performed after each stage. All treatment procedures are conducted in accordance with routine clinical practice; no additional randomization or mandatory intervention is applied beyond the standard of care. The study solely observes and records outcomes associated with this treatment strategy.

Studieoversikt

Status

Rekruttering

Forhold

Intervensjon / Behandling

Detaljert beskrivelse

Coronary atherosclerotic heart disease remains one of the leading causes of mortality and disability worldwide. Coronary stent implantation is a principal therapeutic strategy for coronary artery stenosis. The adequacy of stent expansion is a critical determinant of treatment efficacy; inadequate stent expansion may lead to stent malapposition, in-stent restenosis, stent thrombosis, and other adverse events that significantly compromise patient prognosis.

Intravascular ultrasound (IVUS), as an invasive vascular imaging modality, enables clear visualization of vessel wall architecture, plaque characteristics, and immediate post-stent implantation outcomes. Among its measurements, the external elastic membrane (EEM) cross-sectional area serves as a key reference for stent sizing, effectively overcoming the inherent limitation of conventional coronary angiography, which relies solely on luminal imaging for stent diameter selection.

Non-compliant (NC) balloon post-dilation is an essential step in optimizing stent implantation outcomes. Gradual incremental increases in balloon pressure may further promote adequate stent expansion and improve stent-vessel wall apposition. However, the specific impact of NC balloon post-dilation at different pressures and durations on stent expansion rate has not been systematically validated. To date, there remains a paucity of dedicated studies investigating the dynamic changes in stent expansion rate under a stepwise pressure-increasing protocol.

This study utilizes IVUS-EEM measurements to guide stent sizing and adopts a single-stent implantation strategy combined with multi-stage stepwise pressure-increasing NC balloon post-dilation. after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation. IVUS measurement will be made after each step and stent expansion and Minimal stent area will be documented.

Primary Endpoint. Minimum Stent Area (MSA)

IVUS-measured minimum lumen cross-sectional area within the stented segment post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation)

Secondary endpoints:

Stent Expansion Rate

IVUS-measured stent expansion rate immediately post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation), calculated as: (minimum stent cross-sectional area [MSA] measured by IVUS / manufacturer's nominal MSA) × 100%.

rates of stent edge dissection, hematoma, perforation.

Studietype

Intervensjonell

Registrering (Antatt)

150

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

  • Navn: Mingyou Zhang, M.D.
  • Telefonnummer: 8613689842200
  • E-post: zmy@jlu.edu.cn

Studiesteder

    • Jilin
      • Changchun, Jilin, Kina, 130000
        • Rekruttering
        • The First Hospital of Jilin University

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Age ≥18 years regardless of gender;
  • Coronary angiography confirms single-vessel coronary artery stenosis ≥50%, meeting the indication for single-stent implantation;
  • Preoperative IVUS examination can clearly visualize the vessel EEM, allowing for stent size measurement and assessment of stent expansion-related parameters;
  • The patient voluntarily participates in this study and signs the informed consent form;
  • No contraindications related to IVUS examination, stent implantation, or balloon angioplasty.

Exclusion Criteria:

  • Hemodynamically unstable
  • Presence of anatomical or pathological factors preventing IVUS catheter crossing.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Intervensjonsmodell: Enkeltgruppeoppdrag
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: Serial pressure dilation

After stent nominal pressure deployment stent will be postdilated at 12atm*10s, 18atm *10s, 24atm*10s.Final post-dilation will be attempted at 24 atm for up to 120 seconds, with the duration limited to the patient's maximum tolerated time if premature intolerance occurs.IVUS measurement will be done after each dilation for the MSA and stent expansion

Coronary stent implantation followed by serial pressure post-dilation using non-compliant balloon under IVUS guidance

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Minimum Stent Area (MSA)
Tidsramme: 3 days

IVUS-measured minimum lumen cross-sectional area within the stented segment post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation), Final post-dilation will be attempted at 24 atm for up to 120 seconds, with the duration limited to the patient's maximum tolerated time if premature intolerance occurs.

3 days

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Sponsor

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

7. januar 2026

Primær fullføring (Antatt)

30. desember 2026

Studiet fullført (Antatt)

30. desember 2026

Datoer for studieregistrering

Først innsendt

23. september 2026

Først innsendt som oppfylte QC-kriteriene

28. september 2026

Først lagt ut (Faktiske)

1. oktober 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

1. oktober 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

28. september 2026

Sist bekreftet

1. september 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • stepwise stent postdilation

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

UBESLUTTE

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

produkt produsert i og eksportert fra USA

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .