Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Clinical and Biomechanical Evaluation of a Modified Custom-Made Double T Titanium Miniplate for Fixation of Mandibular Angle Fractures

18. november 2026 oppdatert av: hazem naguib, Suez Canal University

Mandibular angle fractures are among the most common and biomechanically challenging maxillofacial injuries due to complex muscular forces and proximity to dental roots. While conventional two-miniplate fixation provides reliable stability, it increases hardware bulk, periosteal stripping, and the risk of iatrogenic injury to adjacent molar roots.

This randomized controlled clinical trial aims to evaluate the clinical and biomechanical performance of a modified custom-made double T titanium miniplate compared to conventional two-miniplate fixation in the management of mandibular angle fractures. Sixteen adult patients with non-comminuted mandibular angle fractures will be randomly assigned into two equal groups (8 patients per group). Group A will undergo open reduction and internal fixation (ORIF) using a preoperative computed tomography (CT)-based, virtually planned, custom-made modified double T titanium miniplate, whereas Group B will be treated using conventional titanium miniplates placed according to Champy's lines of osteosynthesis. Patients will be followed up clinically and radiographically over a 6-month postoperative period to assess fracture stability, bone healing, functional recovery, and postoperative complications.

Studieoversikt

Status

Har ikke rekruttert ennå

Forhold

Intervensjon / Behandling

Detaljert beskrivelse

Study Design and Randomization:

This prospective, parallel-group, randomized clinical trial will be conducted at the Outpatient Clinic of the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Suez Canal University. A total of 16 adult dentate patients (aged 21 years or older) presenting with non-comminuted mandibular angle fractures indicated for open reduction and internal fixation (ORIF) will be enrolled after signing written informed consent. Participants will be randomly allocated in a 1:1 ratio using a computer-generated randomization sequence (Randomizer.org) into two groups:

  • Group A (Study Group, n = 8): Patients will receive a patient-specific, modified custom-made double T titanium miniplate designed via preoperative CT-based virtual surgical planning to provide biplanar stabilization while avoiding mandibular molar roots.
  • Group B (Control Group, n = 8): Patients will receive standard titanium miniplate fixation applied according to Champy's principles of osteosynthesis.

Surgical Protocol:

All surgical procedures will be performed under general anesthesia with nasotracheal intubation via an intraoral approach. Intraoperative maxillomandibular fixation (MMF) will be applied to establish proper occlusion prior to fracture reduction and plate fixation, and will be released 2 days postoperatively. All patients will receive standardized postoperative medications (amoxicillin-clavulanate 1 g every 12 hours for 5 days and ibuprofen 600 mg three times daily for 4 days) along with oral hygiene and soft-diet instructions for 4 weeks.

Follow-up and Evaluation:

Clinical assessments will be conducted at 1 week, 1 month, 3 months, and 6 months postoperatively to evaluate fracture segment mobility, occlusion, pain (Visual Analogue Scale), facial edema (facial linear measurements), maximum mouth opening (digital caliper), inferior alveolar nerve sensory function (cotton wisp test), and wound healing/infection (periodontal probe). Radiographic evaluations using panoramic radiographs and cone-beam computed tomography (CBCT) will be performed at 1 month and 3 months postoperatively to assess fracture reduction and bone density/healing, alongside finite element analysis (FEA) for biomechanical stress distribution.

Studietype

Intervensjonell

Registrering (Antatt)

16

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Studiesteder

    • Ismailia Governorate
      • Ismailia, Ismailia Governorate, Egypt, 41522
        • Faculty of Dentistry , Suez Canal University

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

21 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Adult dentate patients aged 21 years or older.
  • Non-comminuted mandibular angle fracture indicated for open reduction and internal fixation (ORIF).
  • Adequate occlusal stability or correctable occlusion after fracture reduction.
  • Ability and willingness to attend all scheduled postoperative follow-up visits (1 week, 1 month, 3 months, and 6 months).
  • Willingness to provide written informed consent.

Exclusion Criteria:

  • Comminuted mandibular angle fractures or pathological fractures.
  • Edentulous mandible or severely periodontally compromised molars in the fixation zone.
  • Medically compromised patients contraindicating surgical intervention or general anesthesia.
  • Patients presenting with infected mandibular fractures.
  • Patients with malunion fractures.
  • Patients with bone gap defects resulting from gunshot wounds.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: Randomisert
  • Intervensjonsmodell: Parallell tildeling
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: Modified Custom-Made Double T Titanium Miniplate Group

Eight patients with non-comminuted mandibular angle fractures treated via an intraoral open reduction and internal fixation (ORIF) approach using a preoperative CT-based, virtually planned, patient-specific modified double T titanium miniplate and titanium screws.

A patient-specific titanium bone plate with a modified double T configuration designed preoperatively using computed tomography (CT)-based virtual planning and manufactured by Arab Engineer's. During intraoral open reduction and internal fixation (ORIF) under general anesthesia, the plate is adapted across the mandibular angle fracture line to achieve biplanar stabilization while avoiding molar tooth roots, and secured with titanium monocortical screws. Intraoperative maxillomandibular fixation (MMF) is applied and removed 2 days postoperatively.

Andre navn:
  • Patient-Specific Double T Bone Plate
Aktiv komparator: Conventional Titanium Miniplates Group

Eight patients with non-comminuted mandibular angle fractures treated via an intraoral open reduction and internal fixation (ORIF) approach using conventional titanium miniplates and screws placed according to Champy's lines of osteosynthesis.

Standard straight/curved titanium miniplates manufactured by Arab Engineer's. During intraoral open reduction and internal fixation (ORIF) under general anesthesia, conventional miniplates are adapted and fixed across the mandibular angle fracture along Champy's ideal lines of osteosynthesis using titanium screws. Intraoperative maxillomandibular fixation (MMF) is applied and removed 2 days postoperatively.

Andre navn:
  • Standard Champy Titanium Miniplates

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Clinical Fixation Stability at the Fracture Site
Tidsramme: Immediately postoperative, 1 month, 3 months, and 6 months postoperatively

Clinical stability of the proximal and distal mandibular angle fracture segments assessed through gentle bimanual digital manipulation and palpation (Panesar & Susarla method), recorded dichotomously as stable (absence of interfragmentary mobility) or unstable (presence of palpable mobility).

Immediately postoperative, 1 month, 3 months, and 6 months postoperatively
Radiographic Bone Union and Bone Density via Cone-Beam Computed Tomography (CBCT)
Tidsramme: 1 month and 3 months postoperatively

Evaluation of bone healing and osseous union across the mandibular angle fracture line using cone-beam computed tomography (CBCT), quantified by measuring mean bone density in grayscale values / Hounsfield Units (HU) at the fracture site.

1 month and 3 months postoperatively

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Postoperative Pain Intensity Measured by Visual Analogue Scale (VAS)
Tidsramme: 1 week, 1 month, 3 months, and 6 months postoperatively

Subjective postoperative pain intensity evaluated using a 10-cm Visual Analogue Scale (VAS), where 0 indicates no pain and 10 indicates the worst imaginable pain.

1 week, 1 month, 3 months, and 6 months postoperatively
Postoperative Facial Edema Measured by Craniometric Linear Tape Measurements
Tidsramme: 1 week, 1 month, and 3 months postoperatively

Assessment of postoperative facial swelling in millimeters (mm) using standard facial linear measurements between fixed anatomical landmarks (Gabka and Matsumura method) compared to preoperative baseline values.

1 week, 1 month, and 3 months postoperatively
Maximum Interincisal Mouth Opening (Trismus) Measured by Digital Caliper
Tidsramme: 1 week, 1 month, 3 months, and 6 months postoperatively

Evaluation of mandibular functional range of motion by measuring the maximum interincisal distance in millimeters (mm) between the upper and lower central incisors using a calibrated digital caliper.

1 week, 1 month, 3 months, and 6 months postoperatively
Inferior Alveolar Nerve Neurosensory Function Assessed by Cotton Wisp Test
Tidsramme: 1 week, 1 month, 3 months, and 6 months postoperatively

Assessment of lower lip and chin paresthesia/neurosensory recovery using the directional light-touch cotton wisp test (Zuniga & Essick method), scored as normal sensation, hypoesthesia, or anesthesia.

1 week, 1 month, 3 months, and 6 months postoperatively
Mucosal Wound Dehiscence Length Measured by Graduated Periodontal Probe
Tidsramme: 1 week, 1 month, and 3 months postoperatively

Clinical measurement of mucosal wound dehiscence (gap separation along the incision line) in millimeters (mm) using a graduated periodontal probe (Pippi method).

1 week, 1 month, and 3 months postoperatively
Postoperative Dental Occlusion Stability Assessed by Clinical Intercuspation Examination
Tidsramme: Immediately postoperative, 1 week, 1 month, 3 months, and 6 months postoperatively

Clinical evaluation of dental occlusion stability and intercuspation, recorded as satisfactory pre-trauma occlusion, minor occlusal discrepancy requiring guiding elastics (for 1-2 weeks), or malocclusion.

Immediately postoperative, 1 week, 1 month, 3 months, and 6 months postoperatively
Incidence of Surgical Site Infection Assessed by Clinical Inspection
Tidsramme: • 1 week, 1 month, and 3 months postoperatively

Number and percentage of participants developing clinical signs of surgical site infection (purulent discharge, localized erythema, or hardware exposure) assessed via direct intraoral clinical examination.

• 1 week, 1 month, and 3 months postoperatively

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Sponsor

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

15. desember 2026

Primær fullføring (Antatt)

15. desember 2027

Studiet fullført (Antatt)

15. januar 2028

Datoer for studieregistrering

Først innsendt

14. november 2026

Først innsendt som oppfylte QC-kriteriene

18. november 2026

Først lagt ut (Faktiske)

25. november 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

25. november 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

18. november 2026

Sist bekreftet

1. juli 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • 1142/2026

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

IPD-planbeskrivelse

Individual participant data (IPD) will not be publicly shared in order to protect patient confidentiality and comply with the privacy regulations of the Research Ethics Committee at the Faculty of Dentistry, Suez Canal University. De-identified aggregate results will be published in the doctoral thesis and peer-reviewed scientific journals.

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .