Left Ventricular Torsional Hysteresis: A Global Parameter for Diastolic Function
Diastolic dysfunction refers to abnormal mechanical properties of the myocardium and includes abnormal LV diastolic distensibility, impaired filling and slow or delayed relaxation- regardless of whether the ejection fraction is normal or depressed and whether the patient is asymptomatic or symptomatic. Epidemiologic studies have demonstrated high prevalence of diastolic heart failure (DHF). The quality of life of these patients is impaired and the clinical outcomes are similar to those with heart failure with systolic dysfunction. Therefore diastolic dysfunction has significant adverse economic impact that is expected to grow further with time. Clinical characteristics alone may not be sufficient to diagnose diastolic dysfunction. A number of invasive and non-invasive parameters have been proposed to diagnose diastolic dysfunction. Most of the presently used non-invasive parameters have a number of limitations. High fidelity measurement of the left ventricular pressures is needed to accurately diagnose diastolic dysfunction. Obtaining it in routine clinical practice is impractical.
In this protocol the investigators have proposed a novel non-invasive parameter called 'Torsional Hysteresis' as a measure of diastolic function. This will be measured using non-invasive cardiac MRI technique. During left ventricular contraction and relaxation, myocardium deforms. During cardiac cycle the myocardium goes back to baseline state prior to beginning of each contraction. However the rate with which it returns to the baseline state is variable. Torsion indicates relative wringing motion of the ventricle around a left ventricular axis and is a global parameter of left ventricular deformation. The parameters have defined a new parameter called torsional hysteresis based on non invasive cardiac MRI assessment. The parameters have hypothesized that for diastolic dysfunction, the torsional hysteresis area is increased as compared to no diastolic dysfunction group.
Przegląd badań
Status
Status
Warunki
Warunki
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Alabama
-
Birmingham, Alabama, Stany Zjednoczone, 35243
- VA Medical Center
-
Birmingham, Alabama, Stany Zjednoczone, 35294
- UAB Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
Major inclusion criteria: Normal screening LV ejection fraction.
Exclusion Criteria:
- Atrial fibrillation or other significant cardiac arrhythmia on ECG
- Presence of pacemaker or defibrillator
- Angioplasty or primary coronary intervention PCI/PTCA during index cardiac catheterization.
- Patient is unable to undergo cardiac MRI due to contraindication to MRI (MRI incompatible metal prosthesis or implants or significant claustrophobia).
- Patient taking phosphodiesterase 5 inhibitor (eg. sildenafil) will be excluded due to potential interaction with nitroglycerin.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Modele obserwacyjne: Tylko przypadek
- Perspektywy czasowe: Spodziewany
Liczba grup / kohort
Kohorty i interwencje
Grupa / KohortaGrupa / Kohorta |
|---|
|
Diastolic Function
Patients scheduled for cardiac catheterization.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
To show that torsional hysteresis relates to invasive hemodynamic measure of diastolic function
Ramy czasowe: one time at enrollment
|
To show that torsional hysteresis relates to invasive hemodynamic measure of diastolic function: a) Exponential fall of pressure during isovolumic relaxation phase by the time constant of relaxation, tau and b) LV end diastolic pressure-volume relationship (EDPVR).
|
one time at enrollment
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
To demonstrate that torsional hysteresis is a relatively load independent measure of global diastolic function
Ramy czasowe: one time at enrollment
|
To demonstrate that torsional hysteresis is a relatively load independent measure of global diastolic function by evaluating effects of nitroglycerin (NTG) on torsional hysteresis and correlating it to invasive hemodynamic measure of diastolic function including a) tau and b) EDPVR.
|
one time at enrollment
|
|
To evaluate the sensitivity and specificity of torsional hysteresis in diagnosing diastolic dysfunction
Ramy czasowe: one time at enrollment
|
To evaluate the sensitivity and specificity of torsional hysteresis in diagnosing diastolic dysfunction (as defined by invasive hemodynamic parameters: tau, EDPVR) and compare it to echocardiographic tissue Doppler assessment in patients undergoing cardiac catheterization for suspected diastolic dysfunction
|
one time at enrollment
|
Współpracownicy i badacze
Sponsor
Sponsor
Współpracownicy
Współpracownicy
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- F101215002
- 5R01HL104018 (Grant/umowa NIH USA)
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .