Evaluation of an Karajishi Contour Investigational Blood Glucose Monitoring System (ISO/FDA Study)
User Performance of the Karajishi Contour Blood Glucose Monitoring System (ISO/FDA Study)
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
California
-
Escondido, California, Stany Zjednoczone, 92026
- AMCR Institute
-
-
Washington
-
Renton, Washington, Stany Zjednoczone, 98057
- Rainier Clinical Research Center
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Males and females, 18 years of age and older
- Able to speak, read, and understand English
- Willing to complete all study procedures
Exclusion Criteria:
- Hemophilia or any other bleeding disorder
- Pregnancy
- Physical, visual, or neurological impairments that would make the person unable to perform testing with the BGM
- Previously participated in a BG monitor study using the Karajishi Contour BGMS (or used a Bayer Contour meter)
- Work for a medical laboratory, hospital, or other clinical setting that involves training on and clinical use of blood glucose monitors
- Work for a competitive medical device company, or having an immediate family member who works for such a company
- A condition which, in the opinion of the investigator or designee, would put the person or study conduct at risk
General enrollment guidelines:
- Most subjects will be persons with type 1 or type 2 diabetes
- At least 10% of subjects with diabetes will have type 1 diabetes
- Approximately 10% of subjects will be persons without diabetes
- At least 60% of subjects will be younger than age 65
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie podtrzymujące
- Przydział: Nielosowe
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: Persons With Diabetes
Untrained subjects WITH Diabetes use Karajishi Contour BGMS (Blood Glucose Monitoring System).
|
Untrained subjects WITH diabetes use the Karajishi Contour BGMS (Blood Glucose Monitoring System).
Subjects tested capillary fingerstick blood (and study staff tested subject fingerstick blood) using the Karajishi Contour BGMS.
All BG results were compared to reference method results obtained with subject capillary plasma.
Also, study staff tested subject venous blood and BG results were compared to reference method results obtained from subject venous plasma.
|
|
Eksperymentalny: Persons With and Without Diabetes
Untrained subjects WITH/WITHOUT Diabetes use Karajishi Contour BGMS (Blood Glucose Monitoring System).
|
Untrained subjects WITH and WITHOUT diabetes use Karajishi Contour BGMS (Blood Glucose Monitoring System).
Subjects tested capillary fingerstick blood (and study staff tested subject fingerstick blood) using the Karajishi Contour BGMS.
All BG results were compared to reference method results obtained with subject capillary plasma.
Also, study staff tested subject venous blood and BG results were compared to reference method results obtained from subject venous plasma.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of Self-Test Fingerstick Blood Glucose (BG) Results Within +/- 15 mg/dL (<100 mg/dL) and Within +/- 15% (>=100 mg/dL) of Laboratory Glucose Method
Ramy czasowe: 1 hour
|
Untrained subjects WITH diabetes (329) self-tested fingerstick blood using an investigational Blood Glucose Monitoring System (BGMS).
BGMS results were compared with subject capillary plasma BG results obtained with a Yellow Springs Instrument (YSI) Analyzer.
YSI Analyzer BG results were used to calculate the number of BGMS results within +/-15 mg/dL (<100 mg/dL YSI capillary plasma) and +/-15% (>=100 mg/dL YSI capillary plasma).
|
1 hour
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of Venous Blood Glucose (BG) Results Within +/- 15 mg/dL (<100 mg/dL) and Within +/- 15% (>=100 mg/dL) of Laboratory Glucose Method
Ramy czasowe: 1 hour
|
Study staff tested venous blood of subjects WITH diabetes (329) using an investigational Blood Glucose Monitoring System (BGMS).
Venous BGMS results were compared with subject venous plasma BG results obtained with a Yellow Springs Instrument (YSI) Analyzer.
YSI Analyzer venous plasma BG results were used to calculate the number of BGMS results within +/-15 mg/dL (<100 mg/dL YSI venous plasma) and +/-15% (>=100 mg/dL YSI venous plasma).
|
1 hour
|
|
Number of Fingerstick Blood Glucose (BG) Results Within +/- 15 mg/dL (<100 mg/dL) and Within +/- 15% (>=100 mg/dL) of Laboratory Glucose Method When Obtained and Tested by Study Staff
Ramy czasowe: 1 hour
|
Study staff obtained and tested subject (329 WITH diabetes) fingerstick blood using an investigational Blood Glucose Monitoring System (BGMS).
BGMS results were compared with subject capillary plasma BG results obtained with a Yellow Springs Instrument (YSI) Analyzer.
YSI capillary plasma results were used to calculate the number of BGMS results within +/-15 mg/dL (<100 mg/dL YSI capillary plasma) and +/-15% (>=100 mg/dL YSI capillary plasma).
|
1 hour
|
|
Number of Responses From Persons With Diabetes That Either 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire Statements
Ramy czasowe: 1 hour
|
Staff obtained responses from persons WITH diabetes (329) using short questionnaires to provide feedback on instructions for use and the basic operation of the BGMS.
Subjects could respond 'Strongly Agree' or 'Agree' or 'Neutral' or 'Disagree' or 'Strongly Disagree.'
|
1 hour
|
|
Number of Self-Test Fingerstick Blood Glucose (BG) Results Within +/- 15% of Laboratory Glucose Method Across the Tested Glucose Range
Ramy czasowe: 1 hour
|
Untrained subjects WITH diabetes (329) and WITHOUT diabetes (43) self-tested fingerstick blood using an investigational Blood Glucose Monitoring System (BGMS).
BGMS results were compared with subject capillary plasma BG results obtained with a Yellow Springs Instrument (YSI) Analyzer.
YSI Analyzer BG results were used to calculate the number of BGMS results within +/-15% of the laboratory method across the entire tested YSI glucose range.
|
1 hour
|
|
Number of Self-Test Fingerstick Blood Glucose (BG) Results Within +/- 20% of Laboratory Glucose Method Across the Tested Glucose Range
Ramy czasowe: 1 hour
|
Untrained subjects WITH diabetes (329) and WITHOUT diabetes (43) self-tested fingerstick blood using an investigational Blood Glucose Monitoring System (BGMS).
BGMS results were compared with subject capillary plasma BG results obtained with a Yellow Springs Instrument (YSI) Analyzer.
YSI Analyzer BG results were used to calculate the number of BGMS results within +/-20% of the laboratory method across the entire tested YSI glucose range.
|
1 hour
|
|
Number of Subject Fingerstick Blood Glucose (BG) Results Within +/- 15% of Laboratory Glucose Method When Obtained and Tested by Study Staff
Ramy czasowe: 1 hour
|
Study staff obtained and tested subject (WITH and WITHOUT diabetes) fingerstick blood using an investigational Blood Glucose Monitoring System (BGMS).
BGMS results were compared with subject capillary plasma BG results obtained with a Yellow Springs Instrument (YSI) Analyzer.
YSI capillary plasma results were used to calculate the number of BGMS results within +/-15% across the tested YSI glucose range.
|
1 hour
|
|
Number of Subject Fingerstick Blood Glucose (BG) Results Within +/- 20% of Laboratory Glucose Method When Obtained and Tested by Study Staff
Ramy czasowe: 1 hour
|
Study staff obtained and tested subject (WITH and WITHOUT diabetes) fingerstick blood using an investigational Blood Glucose Monitoring System (BGMS).
BGMS results were compared with subject capillary plasma BG results obtained with a Yellow Springs Instrument (YSI) Analyzer.
YSI capillary plasma results were used to calculate the number of BGMS results within +/-20% across the tested YSI glucose range.
|
1 hour
|
|
Number of Subject Responses That Either 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire Statements
Ramy czasowe: 1 hour
|
Staff obtained responses from subjects WITH and WITHOUT diabetes using short questionnaires to provide feedback on instructions for use and the basic operation of the BGMS.
Subjects could respond 'Strongly Agree' or 'Agree' or 'Neutral' or 'Disagree' or 'Strongly Disagree.'
|
1 hour
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Główny śledczy: Leslie J Klaff, MD, Rainier Clinical Research Center
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- GCA-2014-002-01
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .