A Prospective, Multi-Center, Pivotal Study to Evaluate the Safety and Effectiveness of the NovaCross™ Micro-catheter in Facilitating Crossing Chronic Total Occlusion (CTO) Coronary Lesions
A Prospective, Multi-Center, Non-randomized, Single Arm, Open Label, Pivotal Study to Evaluate the Safety and Effectiveness of the NovaCross™ Micro-catheter in Facilitating Crossing Chronic Total Occlusion (CTO) Coronary Lesions
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Krakow, Polska
- SPZOZ University Hospital in Krakow
-
-
-
-
Arkansas
-
Little Rock, Arkansas, Stany Zjednoczone, 72205
- Central Arkansas Veterans Healthcare System
-
-
Illinois
-
Naperville, Illinois, Stany Zjednoczone, 60540
- Edward Hospital
-
-
New York
-
New York, New York, Stany Zjednoczone, 10032
- Columbia University Medical Center/New York Presbyterian Hospital
-
-
Pennsylvania
-
York, Pennsylvania, Stany Zjednoczone, 17403
- York Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Adult aged 25-80
- Patient understands and has signed the study informed consent form.
- Patient has an angiographic documented Chronic Total Occlusion (i.e. >3 months occlusion duration) showing distal TIMI flow 0.
- Suitable candidate for non-emergent, coronary angioplasty
- Documented coronary angiography preceding the PCI reveals at least one CTO lesion situated in a non-infarct related coronary artery or its side branches
- Body Mass Index (BMI) < 40
- Left ventricle ejection fraction > 25%
Exclusion Criteria:
- Patient unable to give informed consent.
- Current participation in another study with any investigational drug or device.
- Patient is known or suspected not to tolerate the contrast agent.
- Aorta-ostial CTO location (Ostial bifurcation origins may be considered), SVG CTO, in-stent CTO.
- Intolerance to Aspirin and/or inability to tolerate a second antiplatelet agent (Clopidogrel and Prasugrel and Ticagrelor).
- Appearance of a fresh thrombus or intraluminal filling defects.
- Recent major cerebrovascular event (history of stroke or TIA within 1 month)
- Cardiac intervention within 4 weeks of the procedure
- Renal insufficiency (serum creatinine of > 2.3mg/dl or 203μmol/L)
- Active gastrointestinal bleeding
- Active infection or fever that may be due to infection
- Life expectancy < 2 years due to other illnesses
- Significant anemia (hemoglobin < 8.0 mg / dl)
- Severe uncontrolled systemic hypertension (> 240 mmHg within 1 month of procedure)
- Severe electrolyte imbalance
- Congestive heart failure [New York Heart Association (NYHA) Class III\IV] CSA Class IV.
- Unstable angina requiring emergent percutaneous trans-luminal coronary angioplasty (PTCA) or coronary artery bypass graft (CABG)
- Recent myocardial infarction (MI) (within the past two weeks)
- Uncontrolled diabetes >2 serum glucose concentrations of >350 mg/dl within 7 days.
- Unwillingness or inability to comply with any protocol requirements
- Pregnant or nursing
- Extensive prior dissection from a coronary guidewire use
- Drug abuse or alcoholism.
- Patients under custodial care.
- Bleeding diathesis or coagulation disorder;
- Kawasaki's disease or other vasculitis
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: NovaCross
NovaCross microcatheter will be used.
|
The NovaCross™ is a guidewire positioning and support microcatheter for improving chronic total occlusion (CTO) crossability.
The NovaCross™ gains its supportive characteristics through the use of a unique operator-controlled Nitinol scaffold and an extendable segment, both at its distal tip.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
MACE
Ramy czasowe: 30 days
|
30 day MACE, defined as the composite of death, myocardial infarction (MI), or urgent revascularization (target vessel revascularization (TVR) or urgent coronary artery bypass surgery (CABG)).
|
30 days
|
|
Intra-procedural technical success
Ramy czasowe: Intra-procedure
|
Intra-procedural technical success, defined as the ability of the NovaCross™ micro-catheter to successfully facilitate placement of a guidewire beyond a native coronary chronic total occlusion (CTO) in the true vessel lumen.
|
Intra-procedure
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
1. The ability to cross the lesion with a guidewire in the true lumen, effectively dilate the CTO lesion, and place a coronary stent with residual lumen stenosis of less than 30% while restoring antegrade TIMI 3 flow.
Ramy czasowe: Procedure
|
1.
The ability to cross the lesion with a guidewire in the true lumen, effectively dilate the CTO lesion, and place a coronary stent with residual lumen stenosis of less than 30% while restoring antegrade TIMI 3 flow.
|
Procedure
|
|
Proximal cap (ability of the NovaCross™ micro-catheter to facilitate a guidewire successfully penetrating the proximal cap of the CTO.)
Ramy czasowe: Procedure
|
2. The ability of the NovaCross™ micro-catheter to facilitate a guidewire successfully penetrating the proximal cap of the CTO.
|
Procedure
|
|
Effectiveness of extendable portion (effectiveness of the extendable portion in intra-CTO microcatheter crossability)
Ramy czasowe: Procedure
|
3. The effectiveness of the extendable portion in intra-CTO microcatheter crossability.
|
Procedure
|
|
Visualization (ability to have full visualization of the NovaCross during the CTO procedure)
Ramy czasowe: Procedure
|
4. The ability to have full visualization of the NovaCross during the CTO procedure.
|
Procedure
|
|
Usability (Assess the usability of the NovaCross™ by the operator)
Ramy czasowe: Procedure
|
5. Assess the usability of the NovaCross™ by the operator.
|
Procedure
|
|
Device-related perforation (at the site of target coronary lesion and/or its proximal reference segment)
Ramy czasowe: Procedure
|
6. Device-related perforation at the site of target coronary lesion and/or its proximal reference segment.
|
Procedure
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Główny śledczy: Simon Walsh, MD, Belfast Health And Social Care Trust
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- NT-CLP-01
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .