Lung Ultrasound Signs and Patterns in COVID-19 Pregnant Women (PINK-CO)
Lung Ultrasound Signs and Patterns in COVID-19 Pregnant Women - "The PINK-CO Protocol"
SARS-CoV-2 impact on pregnant women is not well known yet. Some authors demonstrated that lung ultrasound can give similar results if compared to chest computed tomography and better results if compared to chest x-rays without radiations and limited risks for mother and fetus.
The Lung Ultrasound Score (LUS) can be used to asses the entity and monitor the evolution of lung impairment.
Some authors described an artifact, the "light beam", as a typical ultrasound sign in COVID-19 positive patients.
With our study we hypothesize to understand the prevalence of this sign and other ultrasound signs in pregnant COVID-19 positive patients.
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Udine, Włochy, 33100
- Anesthesiology and Intensive Care Clinic - Department of Medicine - ASUIUD
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- All pregnant COVID 19 positive patients admitted at our institution who had lung ultrasound performed
Exclusion Criteria:
- are < 18 years old
- history of rheumatic disease
- history of spontaneous pneumothorax
- fibrothorax
- history of thoracic surgery
- no consent given
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Light Beam
Ramy czasowe: 24 hours after admission
|
Evaluate the prevalence of the light beam sign
|
24 hours after admission
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Ultrasound patterns
Ramy czasowe: 24 hours after admission
|
Evaluate the prevalence of ultrasound signs and patterns during pregnancy
|
24 hours after admission
|
|
Lung ultrasound score
Ramy czasowe: 24 hours after admission
|
Evaluate if the Lung ultrasound score relates with the clinical presentation of the patient
|
24 hours after admission
|
|
Illness severity
Ramy czasowe: 24 hours after admission
|
Evaluate if the lung ultrasound score relates with the prognosis
|
24 hours after admission
|
|
Length of stay
Ramy czasowe: 24 hours after admission
|
Evaluate if the lung ultrasound score relates with the length of stay
|
24 hours after admission
|
Współpracownicy i badacze
Sponsor
Sponsor
Publikacje i pomocne linki
Publikacje ogólne
- Lichtenstein D. Lung ultrasound in the critically ill. Curr Opin Crit Care. 2014 Jun;20(3):315-22. doi: 10.1097/MCC.0000000000000096.
- Vetrugno L, Bove T, Orso D, Barbariol F, Bassi F, Boero E, Ferrari G, Kong R. Our Italian experience using lung ultrasound for identification, grading and serial follow-up of severity of lung involvement for management of patients with COVID-19. Echocardiography. 2020 Apr;37(4):625-627. doi: 10.1111/echo.14664. Epub 2020 Apr 15.
- Lichter Y, Topilsky Y, Taieb P, Banai A, Hochstadt A, Merdler I, Gal Oz A, Vine J, Goren O, Cohen B, Sapir O, Granot Y, Mann T, Friedman S, Angel Y, Adi N, Laufer-Perl M, Ingbir M, Arbel Y, Matot I, Szekely Y. Lung ultrasound predicts clinical course and outcomes in COVID-19 patients. Intensive Care Med. 2020 Oct;46(10):1873-1883. doi: 10.1007/s00134-020-06212-1. Epub 2020 Aug 28. Erratum In: Intensive Care Med. 2020 Sep 25;:
- Rasmussen SA, Smulian JC, Lednicky JA, Wen TS, Jamieson DJ. Coronavirus Disease 2019 (COVID-19) and pregnancy: what obstetricians need to know. Am J Obstet Gynecol. 2020 May;222(5):415-426. doi: 10.1016/j.ajog.2020.02.017. Epub 2020 Feb 24.
- Bouhemad B, Mongodi S, Via G, Rouquette I. Ultrasound for "lung monitoring" of ventilated patients. Anesthesiology. 2015 Feb;122(2):437-47. doi: 10.1097/ALN.0000000000000558. No abstract available.
- Li J, Long X, Wang X, Fang F, Lv X, Zhang D, Sun Y, Hu S, Lin Z, Xiong N. Radiology indispensable for tracking COVID-19. Diagn Interv Imaging. 2021 Feb;102(2):69-75. doi: 10.1016/j.diii.2020.11.008. Epub 2020 Nov 24.
- Convissar DL, Gibson LE, Berra L, Bittner EA, Chang MG. Application of Lung Ultrasound During the COVID-19 Pandemic: A Narrative Review. Anesth Analg. 2020 Aug;131(2):345-350. doi: 10.1213/ANE.0000000000004929.
- Vetrugno L, Sala A, Orso D, Meroi F, Fabbro S, Boero E, Valent F, Cammarota G, Restaino S, Vizzielli G, Girometti R, Merelli M, Tascini C, Bove T, Driul L; PINK-CO study investigators. Lung Ultrasound Signs and Their Correlation With Clinical Symptoms in COVID-19 Pregnant Women: The "PINK-CO" Observational Study. Front Med (Lausanne). 2022 Jan 21;8:768261. doi: 10.3389/fmed.2021.768261. eCollection 2021.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- CEUR-2021-223
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .