Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Restoring Sinus Rhythm Using Dual-Shock Technique in Patients With Atrial Fibrillation (DUAL-SHOCK)

25 lipca 2026 zaktualizowane przez: Martín Negreira Caamaño, MD, PhD

Restoring Sinus Rhythm Using DUAL-electrical SHOCK Technique: the DUAL-SHOCK Trial

The goal of this clinical trial is to assess the efficacy and acute safety of the dual electrical cardioversion (ECV) technique compared with the conventional ECV in patients with persistent atrial fibrillation. The main question it aims to answer are:

  • Is dual ECV more effective than conventional ECV to achieve sinus rhythm restoration?
  • Is dual ECV safe compared with conventional ECV?
  • Which are the main factors associated with cardioversion success?

Researchers will compare a dual ECV technique with 400J with dual ECV with 200J and conventional ECV.

Participants will be randomized to one ECV configuration. The primary efficacy endpoint will be considered the percentage of patients with successful cardioversion with the first shock. The coprimary safety endpoint will be the occurrence of adverse events during ECV.

Przegląd badań

Status

Jeszcze nie rekrutacja

Warunki

Interwencja / Leczenie

Typ studiów

Interwencyjne

Zapisy (Szacowany)

177

Faza

  • Faza 2
  • Faza 3

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Opis

Inclusion Criteria:

  • Diagnosis of persistent AF.
  • Effective anticoagulation for at least 3 weeks prior to the procedure or exclusion of intra-atrial thrombus by transesophageal echocardiography within the last 24 hours.
  • Informed consent obtained.

Exclusion Criteria:

  • Long-standing persistent atrial fibrillation (more than 1 year of uninterrupted AF rhythm).
  • Emergency indication (hemodynamic instability).
  • Cardiac defibrillation following catheter ablation procedures. Cardiac defibrillation performed during the same procedure will be permitted if it is carried out prior to ablation.
  • Pregnancy.
  • Age <18 years or legal incapacity.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Zadanie sekwencyjne
  • Maskowanie: Podwójnie

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: Conventional Electrical Cardioversion
Conventional ECV with single pad configurataion in antero-lateral or antero-posterior location. Energy deliver: 200J

Defibrillation pads will be placed in the anteroposterior or anterolateral position. An initial biphasic shock of 200 J will be delivered. If sinus rhythm is not restored, a second dual shock of 400 J (crossover) will be administered.

The procedures will be performed in the designated area for such procedures at each center, under deep sedation in accordance with each center's standard protocols. The choice of medication used for sedation will be at the investigator's discretion. All shocks will be delivered using biphasic energy and ECG-synchronized.

Eksperymentalny: Dual-Shock 400J
ECV with dual shock technique. Double pad configuration with electrodes both in antero-lateral and antero-posterior location. Total energy deliver: 400J.

Two pairs of defibrillation pads connected to two different defibrillators will be used. One pair of pads will be placed in the anterolateral position and the second pair in the anteroposterior position. Both defibrillators will be programmed to deliver a biphasic shock of 100 J each (200 J group) or 200 J each (400 J group) simultaneously. The maximum number of CVE attempts per patient will be 3.

The procedures will be performed in the designated area for such procedures at each center, under deep sedation in accordance with each center's standard protocols. The choice of medication used for sedation will be at the investigator's discretion. All shocks will be delivered using biphasic energy and synchronized with the QRS complex.

Eksperymentalny: Dual-Shock 200J
ECV with dual shock technique. Double pad configuration with electrodes both in antero-lateral and antero-posterior location. Total energy deliver: 200J.

Two pairs of defibrillation pads connected to two different defibrillators will be used. One pair of pads will be placed in the anterolateral position and the second pair in the anteroposterior position. Both defibrillators will be programmed to deliver a biphasic shock of 100 J each (200 J group) or 200 J each (400 J group) simultaneously. The maximum number of CVE attempts per patient will be 3.

The procedures will be performed in the designated area for such procedures at each center, under deep sedation in accordance with each center's standard protocols. The choice of medication used for sedation will be at the investigator's discretion. All shocks will be delivered using biphasic energy and synchronized with the QRS complex.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Primary Efficacy Outcome - Patients achieving sinus rhythm with the first shock
Ramy czasowe: First minute after first shock delivery
Percentage of patients achieving sinus rhythm with the first shock deliver. Three consecutive beats in sinus rhythm are neccesary to consider sinus rhythm achieved.
First minute after first shock delivery
Primary Safety Outcome - Adverse events during the procedure
Ramy czasowe: Before patient are discharged
Ocurrence of any complication during the ECV. Arrhythmic recurrences of atrial fibrillation will not be considered as complications.
Before patient are discharged

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Overall Procedural Sucess
Ramy czasowe: The end of the procedure
Percentage of patients achieving stable sinus rhythm after any number of shocks
The end of the procedure
Overall Intervention-Specific Success
Ramy czasowe: First minute after shock delivery
Number of successful shocks / Overall delivered shock within the same pad configuration.
First minute after shock delivery
Total Energy Delivered
Ramy czasowe: End of the procedure
Total energy administered (J) before the procedure is completed
End of the procedure
Sub-acute procedural success
Ramy czasowe: At 30 (25-35) days after the procedure
Percentage of patients in sinus rhythm at 30 days after the ECV
At 30 (25-35) days after the procedure

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

1 sierpnia 2026

Zakończenie podstawowe (Szacowany)

31 grudnia 2027

Ukończenie studiów (Szacowany)

27 lutego 2028

Daty rejestracji na studia

Pierwszy przesłany

21 kwietnia 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

28 kwietnia 2026

Pierwszy wysłany (Rzeczywisty)

1 maja 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

28 lipca 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

25 lipca 2026

Ostatnia weryfikacja

1 lipca 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 25-129

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

TAK

Opis planu IPD

Study protocol will be sent for publication

Typ informacji pomocniczych dotyczących udostępniania IPD

  • PROTOKÓŁ BADANIA

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .