Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Clinical Performance of Verofilcon A Toric Contact Lenses

7 maja 2026 zaktualizowane przez: Southern College of Optometry

Clinical Performance of Verofilcon A Toric Contact Lenses in Satisfied Wearers of Senofilcon A Toric Contact Lenses With Blue Light Filtration

The goal of this clinical trial is to [primary purpose: is to determine if Total30 Multi focal toric conntact lensesare comfortable and the willigness for those who have previously worn reusable toric contact lenses are willing to stay in Total30 MFT after 1 month of wear during the duration of the study. Healthy previous reusable toric contact lens weareres will be refit into total30 MFT contact lenses and will be asked to gauge their comfort while wearing the lenses. Healthy adult participants who are presybyopic between the ages of 18-40 can participant, sex and gender are not disqualifiers unless the participant is pregnant or breast feeding. The main question[s] it aims to answer [is/are]

[primary hypothesis or outcome measure 1Proportions of toric CL wearers who have positive visual acuity scores in comfort and vision after one month of wear.

[primary hypothesis or outcome measure 2]? Contact lens dry eye-8 scores will be less than 12 indicating high levels of comfort after one month of wear.

Przegląd badań

Status

Rekrutacyjny

Warunki

Interwencja / Leczenie

Szczegółowy opis

TOTAL30® Multifocal Toric contact lenses (CLs) are a 1-month, silicone hydrogel (lehfilcon A), studies have likewise found the lehfilcon A material to provides a comfortable wearing experience for the full life of the CL and for the full CL wear day.1 While initial TOTAL30 data are promising, the literature currently lacks data directly related to the Total30 MFT design and a targeted study aimed at evaluating how Total30 MFT performs with regards to overall comfort, vision, and satisfaction for those who are previous reusable toric CL wearers and are now presbyopic. This transition could be particularly important for patients who are presbyopic and astigmatic given that these two patients groups tend to struggle more with CLs than spherical CL wearers. Thus, the purpose of this work is to determine Total30 MFT overall comfort, vision, willingness to remain in CLs after the study, and satisfaction for those who currently wear reusable silicone hydrogel toric CLs and are now presbyopic. These data will provide valuable information to partitioners for patient educational purposes, and it will provide credence for refitting presbyopic patients who have astigmatism into Total30 MFT, especially after the onset of presbyopia.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

32

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

  • Nazwa: Chris Lievens, OD
  • Numer telefonu: (901) 722-3200
  • E-mail: clievens@sco.edu

Lokalizacje studiów

    • Tennessee
      • Memphis, Tennessee, Stany Zjednoczone, 38104
        • Rekrutacyjny
        • The Southern College of Optometry
        • Kontakt:

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły

Akceptuje zdrowych ochotników

Tak

Opis

Inclusion Criteria:

  • Adults, ≥40-year-old, CL wearers with best-corrected 20/20 distance visual acuity or better.
  • Requiring +0.75 ADD or more at standard near distance of 40 cm.
  • Participants will be required to have worn reusable silicone hydrogel toric CLs in the past year and still at a minimum wearing the CLs occasionally without having significant discomfort or dryness.
  • All participants will be required to have a CLDEQ-8 score <12.
  • Participants will be required to be able to wear Total 30MFT CLs (presbyopic plus astigmatism both ≥0.75D OD and OS).
  • Astigmatism ranging from 0.75 D to 2.50 D in each eye.
  • Participants will be required to wear the study CLs for ≥13 hours each day with no overnight wear.
  • Willing to wear study CLs for ≥16 hours on the Day 1 (1st full day), Day 14, and Day 29 when responses will be collected via text message.
  • Participants will be willing to wear the CL every day of the week.
  • Participants will be required to provide a glasses prescription that is less than 3 years old.
  • Visual acuity with habitual reusable silicone hydrogel toric CLs is 20/25 or better in each eye.

Exclusion Criteria:

  • Have worn Total30 MFT in the past
  • Are past rigid CL wearers
  • Are currently wearing monovision CLs
  • Have a history of being diagnosed with dry eye or ocular allergies
  • Have known systemic health conditions that are thought to alter tear film physiology
  • Have a history of viral eye disease
  • Have a history of ocular surgery
  • Have a history of severe ocular trauma
  • Have a history of corneal dystrophies or degenerations
  • Have active ocular infection or inflammation
  • Are currently using isotretinoin-derivatives or ocular medications
  • Are pregnant or breast feeding

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Nie dotyczy
  • Model interwencyjny: Zadanie dla jednej grupy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: TOTAL30 Multifocal Toric contact lenses
This will be a prospective study to understand if reusable silicone hydrogel toric CL wearers who are presbyopic can be successfully refit into Total30 MFT CLs
Participants will be refit into total 30 contact lenses

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Visual acuity scores
Ramy czasowe: 1 month
This will be a prospective study to understand if reusable silicone hydrogel toric CL wearers who are presbyopic can be successfully refit into Total30 MFT CLs VAS scores will be judged from -50 to positive 50 with positive numbers being more comfortable and 0 being neutral.
1 month

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Contact lens dry eye 8 questionnaire scores
Ramy czasowe: 1 month
Proportion of reusable silicone hydrogel toric CL wearers who have asymptomatic Contact Lens Dry Eye-8 (CLDEQ-8; scores <12) scores one month after wearing Total30 MFT CL
1 month
Comfort VAS
Ramy czasowe: Day 1, Day 14 and day 29 text messages
Comfort VAS after application and at 8, 12, and 16 hours of wear on Day 1 (1st full day), Day14, and Day 29 via text.
Day 1, Day 14 and day 29 text messages

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

1 kwietnia 2026

Zakończenie podstawowe (Szacowany)

1 sierpnia 2026

Ukończenie studiów (Szacowany)

1 września 2026

Daty rejestracji na studia

Pierwszy przesłany

7 maja 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

7 maja 2026

Pierwszy wysłany (Rzeczywisty)

14 maja 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

14 maja 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

7 maja 2026

Ostatnia weryfikacja

1 maja 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • IRB00006763-Total30MFT

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Tak

produkt wyprodukowany i wyeksportowany z USA

Tak

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .