Continuous Glucose Monitoring Alerts, Accuracy, and Patient Outcomes in Adults With Inherited Metabolic Disorders
Continuous Glucose Monitoring Alerts, Accuracy, and Patient Outcomes in Adults With Inherited Metabolic Disorders Prone to Hypoglycemia
The goal of this clinical trial is to learn if a continuous glucose monitor (CGM) with predictive alerts works better than a CGM with standard alerts to prevent low blood sugar (hypoglycemia) in adults with inherited metabolic disorders (IMDs), such as glycogen storage disorders (GSDs) and congenital hyperinsulinism (CH).
The main questions it aims to answer are:
Does a CGM with predictive alerts lower the time spent with low blood sugar compared to a CGM with standard alerts? Do participants feel better and behave differently when using a CGM with predictive alerts? How accurate are the two CGM devices in this group of people? Researchers will compare two CGM devices - Dexcom G7 (with predictive and standard alerts) and Dexcom ONE+ (with standard alerts only) - to see if predictive alerts help reduce low blood sugar episodes and improve quality of life.
Participants will:
Wear each CGM device for 30 days Have a 30-day break between the two devices Check blood sugar levels and record food intake Complete questionnaires about their experience with each device
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Padova
-
Padova, Padova, Włochy, 35128
- University Hospital Of Padova
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Age 18 years or older
- Genetic or biochemical diagnosis of Glycogen Storage Disease (GSD) or Congenital Hyperinsulinism (CH)
- At least one clinical and biochemical follow-up at the hospital outpatient service within the last one or two years
- Ability to sign informed consent and comply with study procedures
Exclusion Criteria:
- Inability to sign informed consent or comply with study procedures
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie podtrzymujące
- Przydział: Randomizowane
- Model interwencyjny: Zadanie krzyżowe
- Maskowanie: Brak (otwarta etykieta)
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Aktywny komparator: Dexcom G7 (Threshold + Predictive Alerts)
|
The Dexcom G7 is a CE-marked continuous glucose monitoring (CGM) device worn for 30 days.
It provides real-time interstitial glucose readings every 5 minutes.
The device offers both threshold-based alerts, activated when glucose levels fall below or rise above pre-set values, and predictive alerts, activated when glucose levels are predicted to reach a threshold within 20 minutes.
The low glucose alert threshold was set at 70 mg/dL for all participants.
|
|
Aktywny komparator: Dexcom ONE+ (Threshold-Only Alerts)
|
The Dexcom ONE+ is a CE-marked continuous glucose monitoring (CGM) device worn for 30 days.
It provides real-time interstitial glucose readings every 5 minutes.
The device offers threshold-based alerts only, activated when glucose levels fall below or rise above pre-set values, without predictive alert functionality.
The low glucose alert threshold was set at 70 mg/dL for all participants.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Time Below Range (TBR)
Ramy czasowe: 30 days per device (total study duration: approximately 90 days including washout period)
|
Percentage of time spent with interstitial glucose levels below 70 mg/dL, as measured by continuous glucose monitoring (CGM). TBR is reported at two thresholds: TBR1 (54-69 mg/dL) and TBR2 (<54 mg/dL), both expressed as percentage of monitoring time (%), over 30 days for each device. Unit of Measure: % of monitoring time |
30 days per device (total study duration: approximately 90 days including washout period)
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Time in Range (TIR)
Ramy czasowe: Time Frame: 30 days per device
|
Percentage of time spent with interstitial glucose levels within the target range of 70-140 mg/dL, as measured by CGM over 30 days for each device. Expressed as percentage of monitoring time (%). Unit of Measure: % of monitoring time |
Time Frame: 30 days per device
|
|
Time Above Range (TAR)
Ramy czasowe: Time Frame: 30 days per device
|
Percentage of time spent with interstitial glucose levels above 140 mg/dL, as measured by CGM over 30 days for each device. Expressed as percentage of monitoring time (%). Unit of Measure: % of monitoring time |
Time Frame: 30 days per device
|
|
Mean Glucose Level
Ramy czasowe: Time Frame: 30 days per device
|
Mean interstitial glucose levels calculated over 24 hours and during nighttime (00:00-07:00), as measured by CGM over 30 days for each device. Unit of Measure: mg/dL |
Time Frame: 30 days per device
|
|
Sensor Accuracy - median absolute relative difference (MARD)
Ramy czasowe: 30 days per device
|
Accuracy of CGM readings compared to capillary blood glucose reference values (Accu-Check Instant, Roche), expressed as Median Absolute Relative Difference (MARD). Capillary and CGM values matched within a ±5-minute time window. Unit of Measure: % |
30 days per device
|
|
Dietary Intake Assessment
Ramy czasowe: 7 days per device
|
Total daily energy intake measured during each device wear period Unit of Measure: kcal/day Total daily macronutrient intake measured during each device wear period Unit of Measure: grams/day Daily uncooked cornstarch intake measured during each device wear period Unit of Measure: grams/day All dietary intakes were assessed by 7-day food diary analyzed with Metadieta® software (Meteda Srl, Italy), completed during CGM monitoring and reviewed by an experienced metabolic dietitian.
|
7 days per device
|
|
Hypoglycemia Fear and Protective Behaviors Assessment
Ramy czasowe: baseline and after 30 days per device
|
Assessed using the Hypoglycemia Fear Survey (HFS), comprising two subscales: Worry (HFS-W) and Behavior (HFS-B). Each item scored 0-4; total range 0-132; higher scores indicate greater fear of hypoglycemia and more behaviors engaged to avoid hypoglycemic episodes. Unit of Measure: Score (0-132) |
baseline and after 30 days per device
|
|
Hypoglycemia Awareness Assessment
Ramy czasowe: baseline and after 30 days per device
|
Assessed using the Clarke Hypoglycemia Awareness Questionnaire (CHAQ), comprising 8 items on hypoglycemia awareness and recognition. Range 0-7; scores ≥4 indicate impaired awareness of hypoglycemia; higher scores indicate worse hypoglycemia awareness. Unit of Measure: Score (0-7) |
baseline and after 30 days per device
|
|
Sleep Quality Assessment
Ramy czasowe: Baseline and after 30 days per device
|
assessed using the Pittsburgh Sleep Quality Index (PSQI), a self-report questionnaire assessing sleep quality and disturbances over the previous month. Global score ranges from 0 to 21; scores >5 indicate poor sleep quality; higher scores indicate worse sleep quality. Unit of Measure: Score (0-21) |
Baseline and after 30 days per device
|
|
Health-Related Quality of Life Assessment
Ramy czasowe: Baseline and after 30 days per device
|
Assessed using the 12-Item Short Form Health Survey (SF-12), yielding Physical Component Summary (PCS) and Mental Component Summary (MCS) standardized scores. Higher scores indicate better quality of life. Unit of Measure: Standardized score for Italian population |
Baseline and after 30 days per device
|
|
Body Mass Index (BMI)
Ramy czasowe: Baseline and after 30 days per device
|
Height measured at baseline; weight measured at the start and end of each CGM period using a calibrated mechanical scale (Seca 700). BMI calculated as weight (kg)/height² (m²), interpreted according to WHO classification: <18.5 underweight; 18.5-25 healthy weight; 25-30 overweight; >30 obesity. Unit of Measure: kg/m² |
Baseline and after 30 days per device
|
Współpracownicy i badacze
Sponsor
Sponsor
Współpracownicy
Współpracownicy
Publikacje i pomocne linki
Publikacje ogólne
- Gugelmo G, Maines E, Boscari F, Lenzini L, Fadini GP, Burlina A, Avogaro A, Vitturi N. Continuous glucose monitoring in patients with inherited metabolic disorders at risk for Hypoglycemia and Nutritional implications. Rev Endocr Metab Disord. 2024 Oct;25(5):897-910. doi: 10.1007/s11154-024-09903-y. Epub 2024 Oct 1.
- Rossi A, Venema A, Haarsma P, Feldbrugge L, Burghard R, Rodriguez-Buritica D, Parenti G, Oosterveer MH, Derks TGJ. A Prospective Study on Continuous Glucose Monitoring in Glycogen Storage Disease Type Ia: Toward Glycemic Targets. J Clin Endocrinol Metab. 2022 Aug 18;107(9):e3612-e3623. doi: 10.1210/clinem/dgac411.
- Overduin RJ, Venema A, Lubout CMA, Fokkert-Wilts MJ, De Boer F, Schreuder AB, Rossi A, Derks TGJ. Continuous glucose monitoring metrics in people with liver glycogen storage disease and idiopathic ketotic hypoglycemia: A single-center, retrospective, observational study. Mol Genet Metab. 2024 Sep-Oct;143(1-2):108573. doi: 10.1016/j.ymgme.2024.108573. Epub 2024 Aug 30.
- Peeks F, Hoogeveen IJ, Feldbrugge RL, Burghard R, de Boer F, Fokkert-Wilts MJ, van der Klauw MM, Oosterveer MH, Derks TGJ. A retrospective in-depth analysis of continuous glucose monitoring datasets for patients with hepatic glycogen storage disease: Recommended outcome parameters for glucose management. J Inherit Metab Dis. 2021 Sep;44(5):1136-1150. doi: 10.1002/jimd.12383. Epub 2021 May 5.
- Ferreira CR, Rahman S, Keller M, Zschocke J; ICIMD Advisory Group. An international classification of inherited metabolic disorders (ICIMD). J Inherit Metab Dis. 2021 Jan;44(1):164-177. doi: 10.1002/jimd.12348.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
- Metabolizm, Wrodzone Błędy
- Choroby genetyczne, wrodzone
- Choroby metaboliczne
- Choroby Układu Pokarmowego
- Niemowlę, noworodek, choroby
- Zaburzenia metabolizmu glukozy
- Choroby trzustki
- Hiperinsulinizm
- Metabolizm węglowodanów, błędy wrodzone
- Wrodzone, dziedziczne i noworodkowe choroby i nieprawidłowości
- Choroby żywieniowe i metaboliczne
- Hipoglikemia
- Choroba spichrzeniowa glikogenu
- Wrodzony hiperinsulinizm
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- CET 6104/AO/24, URC AOP3544
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .