Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Collecting Data on Retinal Blood Blood Flow and Blood Vessel Shape/Appearance Using an Investigational Device, XyCAM CRE, and to Then Compare Those Images With Images Collected From a Patient's Routine Clinical Examination.

6 czerwca 2026 zaktualizowane przez: Oday Alsheikh M.D., Stuart Terry Eye Associates

Evaluation of Patients With Retinal Disorders Utilizing the XyCAM CRE Camera.

The primary objective of the XyCAM CRE Camera Study is to evaluate retinal blood flow, choroidal blood flow, and retinal structural features and their association with the progression and characterization of retinal diseases using the XyCAM CRE Camera. The XyCAM CRE is an investigational, noninvasive optical imaging instrument manufactured by Vasoptic Medical, Inc.

XyCAM CRE imaging data will be collected and compared with established retinal imaging modalities currently used in ophthalmic clinical practice, including Color Fundus Photography (CFP), Optical Coherence Tomography (OCT), Optical Coherence Tomography Angiography (OCTA), and Fluorescein Angiography (FA). Imaging data obtained from XyCAM CRE and reference modalities will be assessed to investigate correlations, agreement, and differences between measurements in order to evaluate the potential of XyCAM CRE to provide complementary diagnostic and disease management information in retinal disease.

Secondary objectives of the study include:

Comparing image quality and image-derived information obtained from XyCAM CRE with other clinical reference imaging modalities across different operators and a diverse study population representative of the general population; Investigating the relationship between XyCAM CRE imaging data and established clinical indicators of glaucoma, macular degeneration, hypertensive retinopathy, diabetic retinopathy, inherited retinal disease, and retinal vascular disease.

Przegląd badań

Status

Jeszcze nie rekrutacja

Warunki

Interwencja / Leczenie

Szczegółowy opis

This XyCAM CRE Camera Study is a prospective longitudinal observational cohort imaging study. It is a non-randomized, non-masked, early feasibility study designed to collect retinal imaging data from healthy adults with normal retinal findings and from patients diagnosed with retinal and ocular diseases.

The study will consist of two phases: 1) screening and 2) testing. Patients presenting for routine ophthalmic standard of care evaluations will be screened for eligibility.

Eligible participants will complete four testing visits scheduled approximately 4 months apart (±2 months). At each testing visit, the Principal Investigator (PI) and designated study personnel will document participants' clinical status, obtain intraocular pressure (IOP) and blood pressure (BP) measurements, and acquire repeat XyCAM CRE retinal images. No additional follow-up will be required after completion of Visit 4 procedures.

The XyCAM CRE is an investigational, noninvasive optical imaging system manufactured by Vasoptic Medical, Inc. The device acquires rapid sequential digital retinal images while illuminating the retina with a low-power laser. Proprietary software algorithms analyze the image sequences to estimate retinal blood flow dynamics and generate additional quantitative vascular and structural measurements that may have diagnostic or disease-monitoring value.

The purpose of this study is to investigate the clinical utility of retinal and choroidal blood flow imaging and to evaluate the potential role of XyCAM CRE-derived measurements in the diagnosis and management of ocular disease. Up to 350 participants will be enrolled at Stuart Terry Eye Associates

During study visits, retinal imaging data obtained using XyCAM CRE will be compared with data obtained from established retinal imaging modalities currently used in ophthalmic clinical practice, including Color Fundus Photography (CFP), Optical Coherence Tomography (OCT), Optical Coherence Tomography Angiography (OCTA), and Fluorescein Angiography (FA). The study will utilize:

  1. Laser Speckle Contrast Imaging (LSCI) using the investigational XyCAM CRE system; and
  2. Retrospective and/or clinically acquired reference imaging data from CFP, OCT, OCTA, and FA obtained using standard clinical imaging systems.

LSCI-based retinal blood flow imaging has demonstrated potential as a diagnostic biomarker for assessing disease presence, severity, and progression. Accordingly, LSCI technology implemented in the investigational XyCAM CRE system is the primary imaging modality under evaluation in this study.

XyCAM CRE will be used to obtain retinal blood flow (RBF) measurements from one or more retinal regions. Imaging data will be stored in de-identified form and analyzed to generate region-specific RBF metrics for comparison with participant clinical status and measurements derived from reference imaging modalities.

This study also seeks to establish a broader reference dataset of retinal blood flow measurements obtained from both healthy and diseased eyes. Currently, there is limited widely accepted normative retinal blood flow data available for clinical comparison. Data collected in this study may contribute to future statistical analyses and support the development of reference datasets for subsequent clinical and research applications.

Alterations in retinal perfusion are associated with multiple vision-threatening ocular conditions, including glaucoma, diabetic retinopathy, retinal vein occlusion, and age-related macular degeneration, as well as systemic and neurologic disorders such as cardiovascular disease and cognitive impairment. In addition, intravitreal anti-vascular endothelial growth factor (anti-VEGF) therapy may influence retinal blood flow, suggesting a potential role for retinal perfusion imaging in treatment monitoring and clinical decision-making.

Through longitudinal retinal and choroidal blood flow imaging, this study aims to further characterize the relationship between microvascular perfusion abnormalities and the progression of common retinal diseases.

Typ studiów

Obserwacyjny

Zapisy (Szacowany)

350

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

  • Nazwa: Yvette L Macias, BA in Biology and Chemistry
  • Numer telefonu: 210-600-0040
  • E-mail: yvettem@lenzaadmin.com

Lokalizacje studiów

    • Texas
      • San Antonio, Texas, Stany Zjednoczone, 78212
        • Stuart Terry Eye Associates
        • Kontakt:

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Tak

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

Adult patient with or without the presence of Retinal Disease, who meets the Inclusion/Exclusion Criteria.

Opis

Inclusion Criteria:

  • The Subject present to the ophthalmology/optometry clinic for eye examination. A signed/dated consent form has been obtained from a Subject who is capable of giving informed consent and compliant with the restrictions and requirements if the protocol.

The Subject is 21 years old with binocular vision.

Exclusion Criteria:

  • The Subject has significant media opacity (eg: a significant corneal scar) The Subject's medical history or health status suggests that the Subject may have an adverse reaction to administration of tropicamide or fluorescein dye.

The Subject has more than 15 dioptors of refractive error. The Subject is less that 21 years of age. The Subject is unable to follow instructions or otherwise unable to complete the study procedures.

The Subject has medical conditions such as nystagmus that will likely prevent the Subject from being able to hold their gaze steady during imaging, reducing the likelihood that high quality data can be acquired from the Subject.

The Subject is pregnant.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
Group A, Healthy Subjects
Subjects with no retinal disease present upon examination.
The investigational XyCAM CRE imaging system will be used to acquire retinal blood flow and structural imaging data. No therapeutic intervention is administered; the device is used for observational imaging and data collection only.
Group B, Subjects with Moderate to Severe Glaucoma
Subjects diagnosed with moderate to severe glaucoma in at least one eye, as determined by the Hodapp-Anderson criteria for glaucomatous visual field loss.
The investigational XyCAM CRE imaging system will be used to acquire retinal blood flow and structural imaging data. No therapeutic intervention is administered; the device is used for observational imaging and data collection only.
Group C, Glaucoma Suspect or Mild Glaucoma Subjects
Subjects diagnosed as glaucoma suspects or with mild glaucoma in at least one eye based on clinical findings including elevated intraocular pressure (IOP), suspicious optic nerve appearance, borderline or early visual field abnormalities, and/or retinal nerve fiber layer (RNFL) thinning identified by Optical Coherence Tomography (OCT).
The investigational XyCAM CRE imaging system will be used to acquire retinal blood flow and structural imaging data. No therapeutic intervention is administered; the device is used for observational imaging and data collection only.
Group D, Subjects with AMD
The Subject has been diagnosed with AMD based on clinical diagnostic criteria for AMD
The investigational XyCAM CRE imaging system will be used to acquire retinal blood flow and structural imaging data. No therapeutic intervention is administered; the device is used for observational imaging and data collection only.
Group E, Subjects with Diabetic Eye Disease
The Subject has been diagnosed via clinical diagnostic guidelines with diabetic eye disease, such as non-proliferative diabetic retinopathy (NPDR), proliferative diabetic retinopathy (PDR), diabetic macular edema (DME), and diabetes without significant ocular pathology visible on fundus examination.
The investigational XyCAM CRE imaging system will be used to acquire retinal blood flow and structural imaging data. No therapeutic intervention is administered; the device is used for observational imaging and data collection only.
Group F, Subjects with Hypertensive Retinopathy
The Subject has been diagnosed with Hypertensive Retinopathy based on clinical diagnostic criteria for Hypertensive Retinopathy.
The investigational XyCAM CRE imaging system will be used to acquire retinal blood flow and structural imaging data. No therapeutic intervention is administered; the device is used for observational imaging and data collection only.
Group G, Pilot Subjects with other ocular pathologies and interventions
The Subject is determined by the Principal Investigator to have pathology or has undergone interventions that may significantly reduce or elevate ocular blood flow; and Subjects in this group are recruited on a pilot basis to assess the preliminary (with limited statistical power) promise of RBF monitoring in a diverse set of pathologies.
The investigational XyCAM CRE imaging system will be used to acquire retinal blood flow and structural imaging data. No therapeutic intervention is administered; the device is used for observational imaging and data collection only.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Correlation of XyCAM CRE retinal blood flow measurements with reference retinal imaging modalities in retinal disease
Ramy czasowe: From enrollment through completion of Visit 4 (approximately 12-18 months). Participants will complete four testing visits scheduled approximately 4 months apart (±2 months).
Retinal blood flow (RBF) data will be obtained using XyCAM CRE imaging and compared with retinal imaging modalities currently used as standard of care in ophthalmology, including Color Fundus Photography (CFP), Optical Coherence Tomography (OCT), Optical Coherence Tomography Angiography (OCTA), and Fluorescein Angiography (FA). Measurements obtained from XyCAM CRE and reference imaging modalities will be assessed for correlation, agreement, and differences to evaluate the potential of XyCAM CRE to provide complementary information for the diagnosis and management of retinal disease.
From enrollment through completion of Visit 4 (approximately 12-18 months). Participants will complete four testing visits scheduled approximately 4 months apart (±2 months).

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Publikacje ogólne

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

15 czerwca 2026

Zakończenie podstawowe (Szacowany)

15 czerwca 2029

Ukończenie studiów (Szacowany)

15 czerwca 2030

Daty rejestracji na studia

Pierwszy przesłany

6 czerwca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

6 czerwca 2026

Pierwszy wysłany (Rzeczywisty)

11 czerwca 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

11 czerwca 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

6 czerwca 2026

Ostatnia weryfikacja

1 maja 2026

Więcej informacji

Terminy związane z tym badaniem

Słowa kluczowe

Dodatkowe istotne warunki MeSH

Inne numery identyfikacyjne badania

  • 20260857

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIEZDECYDOWANY

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Tak

produkt wyprodukowany i wyeksportowany z USA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .