Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Internal Jugular Vein Respiratory Variability as a Marker of Disease Severity in Infant Bronchiolitis (IJV-BRONCH)

20 sierpnia 2026 zaktualizowane przez: Emre Güngör, Eskisehir Osmangazi University

Respiratory Variation of Internal Jugular Vein Diameter as a Novel Ultrasonographic Marker of Disease Severity in Infants With Acute Bronchiolitis: A Prospective Observational Cohort Study

This prospective observational cohort study evaluates whether respiratory-cycle variation in internal jugular vein (IJV) diameter, measured by point-of-care ultrasound, correlates with clinical disease severity in infants 1-23 months of age presenting with acute bronchiolitis. Using a standardized M-mode protocol, the IJV Variability Index ([IJVmax-IJVmin]/IJVmax x 100) will be calculated and compared with the Wang Bronchiolitis Severity Score, four additional validated clinical severity instruments (Modified Tal Score, Respiratory Distress Assessment Instrument, Kristjansson Respiratory Score, Respiratory Assessment Change Score), oxygen saturation, respiratory rate, need for high-flow nasal cannula or supplemental oxygen, pediatric intensive care unit admission, and length of hospital stay. Concurrent lung and diaphragm point-of-care ultrasound will be performed to build a multimodal ultrasound severity model. No intervention is assigned; all ultrasound assessments are performed in addition to standard clinical care and do not alter treatment decisions.

Przegląd badań

Status

Jeszcze nie rekrutacja

Warunki

Interwencja / Leczenie

Szczegółowy opis

Bronchiolitis is among the leading causes of hospitalization in infants under 2 years of age. Existing clinical severity scores show limited inter-observer agreement and weak correlation with oxygenation. Point-of-care ultrasound (lung ultrasound, diaphragm ultrasound) has been studied as an adjunct severity marker in bronchiolitis. Still, respiratory-cycle variability of the internal jugular vein (IJV) diameter has not previously been investigated in this population. A prior reliability study in healthy children demonstrated that right internal jugular vein (RIJV) diameter can be reliably measured by M-mode ultrasound and does not vary significantly across the respiratory cycle in the absence of respiratory distress; the study authors explicitly proposed that RIJV diameter and its respiratory variation be investigated as a surrogate marker of pulmonary function in children with respiratory distress. This study extends that proposed application to infants with acute bronchiolitis. Eligible infants aged 1-23 months meeting AAP (2014) clinical criteria for acute bronchiolitis will undergo a standardized ultrasound protocol (45-degree head elevation, linear probe, right internal jugular vein imaged approximately 1 cm cephalad to the sternoclavicular junction, B-mode identification followed by M-mode measurement of maximal inspiratory and expiratory diameters) performed by a blinded, trained sonographer. We will record concurrent clinical severity scoring, lung ultrasound, and diaphragm ultrasound (excursion, thickening fraction). The primary analysis will test the correlation between the IJV Variability Index and the Wang Bronchiolitis Severity Score; secondary analyses will examine correlations with additional validated severity scores, physiologic parameters, and clinical outcomes (respiratory support escalation, length of stay), as well as inter-/intra-observer reliability and the discriminative performance of a multimodal point-of-care ultrasound model.

Typ studiów

Obserwacyjny

Zapisy (Szacowany)

120

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Lokalizacje studiów

    • Eskişehir
      • Eskişehir, Eskişehir, Turcja (Türkiye), 26480
        • Eskisehir Osmangazi University Faculty of Medicine, Pediatric Emergency Department
        • Kontakt:

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dziecko

Akceptuje zdrowych ochotników

Nie

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

Infants aged 1 to 23 months presenting to the Pediatric Emergency Department with a clinical diagnosis of acute bronchiolitis according to the American Academy of Pediatrics (AAP) clinical criteria will be prospectively enrolled. Eligible participants will be evaluated within the first 6 hours of emergency department presentation after written informed consent is obtained from a parent or legal guardian. Participants will undergo standardized clinical severity assessment and point-of-care ultrasonography of the internal jugular vein, lungs, and diaphragm in addition to routine clinical care. No study-specific therapeutic intervention will be assigned.

Opis

Inclusion Criteria:

  • Infants aged 1-23 months
  • Clinical diagnosis of acute bronchiolitis per AAP (2014) criteria (first wheezing episode following an upper respiratory infection prodrome, with tachypnea, retractions, and/or crackles)
  • Written informed consent obtained from parent/legal guardian
  • Evaluable within the first 6 hours of emergency department presentation

Exclusion Criteria:

  • Underlying congenital heart disease
  • Chronic lung disease (bronchopulmonary dysplasia, cystic fibrosis)
  • Prior history of recurrent wheezing/suspected asthma
  • Anatomical abnormality of the neck or prior history of central venous catheterization or jugular vein thrombosis
  • Hemodynamic instability/shock
  • Immediate need for intubation/mechanical ventilation precluding ultrasound assessment
  • Parent/legal guardian declines consent

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
Acute Bronchiolitis Cohort
Infants aged 1-23 months diagnosed with acute bronchiolitis per AAP (2014) clinical practice guideline criteria, undergoing a standardized point-of-care ultrasound assessment (internal jugular vein, lung, and diaphragm) in addition to standard clinical evaluation and treatment. No intervention is assigned as part of this study; the cohort will be stratified post hoc by clinical severity scores for descriptive and exploratory subgroup analyses.
A standardized point-of-care ultrasonography assessment will be performed in addition to routine clinical evaluation. The protocol includes M-mode assessment of the right internal jugular vein (IJV) to measure maximal and minimal respiratory-cycle diameters and calculate the IJV Variability Index ([IJVmax-IJVmin]/IJVmax × 100). Concurrent lung ultrasonography and diaphragm ultrasonography, including diaphragm excursion and thickening fraction, will also be performed. Ultrasonographic assessments are performed for research measurements only and do not determine or modify clinical treatment decisions.
Inne nazwy:
  • POKUS

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Correlation Between Internal Jugular Vein Respiratory Variability Index and Wang Bronchiolitis Severity Score
Ramy czasowe: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the Internal Jugular Vein (IJV) Variability Index and the Wang Bronchiolitis Severity Score. The IJV Variability Index will be calculated as ([IJVmax - IJVmin] / IJVmax) × 100, where IJVmax and IJVmin represent the maximum and minimum IJV diameters measured during the respiratory cycle. The Wang Bronchiolitis Severity Score ranges from 0 to 12, with higher scores indicating greater disease severity. The association will be quantified using Pearson or Spearman correlation coefficients, as appropriate.
At enrollment (baseline, within 6 hours of emergency department presentation)

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Correlation Between IJV Variability Index and Oxygen Saturation, Respiratory Rate, and Retraction Severity
Ramy czasowe: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and oxygen saturation (SpO2, %), respiratory rate (breaths/minute), and the retraction component of the Wang Bronchiolitis Severity Score. The retraction component ranges from 0 to 3, with higher scores indicating more severe retractions.
At enrollment (baseline, within 6 hours of emergency department presentation)
Association Between IJV Variability Index and Need for High-Flow Nasal Cannula or Supplemental Oxygen Therapy
Ramy czasowe: From enrollment through hospital discharge, assessed up to approximately 7 days
Comparison of baseline IJV Variability Index between infants who require and do not require high-flow nasal cannula (HFNC) or supplemental oxygen therapy during hospitalization.
From enrollment through hospital discharge, assessed up to approximately 7 days
Association Between IJV Variability Index and Pediatric Intensive Care Unit Admission
Ramy czasowe: From enrollment through hospital discharge, assessed up to approximately 7 days
Comparison of baseline IJV Variability Index between infants admitted and not admitted to the pediatric intensive care unit (PICU) during hospitalization.
From enrollment through hospital discharge, assessed up to approximately 7 days
Correlation Between Diaphragm Ultrasound Parameters and IJV Variability Index and Clinical Severity Scores
Ramy czasowe: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation of diaphragm excursion, diaphragm thickening fraction, and inspiratory/expiratory ratio with the IJV Variability Index and clinical severity scores. Clinical severity measures will include the Wang Bronchiolitis Severity Score (range 0-12), Modified Tal Score (range 0-12), Respiratory Distress Assessment Instrument (range 0-17), and Kristjansson Respiratory Score (range 0-10). For all four clinical severity scores, higher scores indicate greater disease or respiratory distress severity.
At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation Between IJV Variability Index and Modified Tal Score
Ramy czasowe: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Modified Tal Score. The Modified Tal Score ranges from 0 to 12, with higher scores indicating greater bronchiolitis severity.
At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation Between IJV Variability Index and Respiratory Distress Assessment Instrument
Ramy czasowe: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Respiratory Distress Assessment Instrument (RDAI). The RDAI assesses wheezing and retractions and ranges from 0 to 17, with higher scores indicating greater respiratory distress.
At enrollment (baseline, within 6 hours of emergency department presentation)
Association Between IJV Variability Index and Respiratory Assessment Change Score
Ramy czasowe: Baseline and 2-4 hours after enrollment
Association between the baseline IJV Variability Index and the Respiratory Assessment Change Score (RACS). RACS quantifies change in respiratory status using the change in the Respiratory Distress Assessment Instrument together with a standardized change in respiratory rate between baseline and follow-up assessment. RACS is a change measure rather than a bounded scale and therefore does not have a fixed theoretical minimum or maximum.
Baseline and 2-4 hours after enrollment
Correlation Between IJV Variability Index and Kristjansson Respiratory Score
Ramy czasowe: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Kristjansson Respiratory Score. The Kristjansson Respiratory Score ranges from 0 to 10, with higher scores indicating greater respiratory disease severity.
At enrollment (baseline, within 6 hours of emergency department presentation)

Inne miary wyników

Miara wyniku
Opis środka
Ramy czasowe
Discriminative Performance of a Multimodal Point-of-Care Ultrasound Model Versus Wang Bronchiolitis Severity Score for Predicting Escalated Respiratory Support
Ramy czasowe: From enrollment through 24 hours after enrollment
Area under the receiver operating characteristic curve (AUC, 95% confidence interval) for a multimodal model combining baseline IJV Variability Index, lung ultrasound score, and diaphragm ultrasound parameters, compared with the Wang Bronchiolitis Severity Score alone using the DeLong test. The lung ultrasound score ranges from 0 to 36, with higher scores indicating greater pulmonary aeration abnormality. The Wang Bronchiolitis Severity Score ranges from 0 to 12, with higher scores indicating greater bronchiolitis severity.
From enrollment through 24 hours after enrollment

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Śledczy

  • Główny śledczy: Emre Güngör, Medical Doctor, Eskisehir Osmangazi University Faculty of Medicine, Department of Pediatrics, Division of Pediatric Emergency Medicine

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Publikacje ogólne

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

1 września 2026

Zakończenie podstawowe (Szacowany)

31 marca 2027

Ukończenie studiów (Szacowany)

31 sierpnia 2027

Daty rejestracji na studia

Pierwszy przesłany

15 sierpnia 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

20 sierpnia 2026

Pierwszy wysłany (Rzeczywisty)

21 sierpnia 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

21 sierpnia 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

20 sierpnia 2026

Ostatnia weryfikacja

1 sierpnia 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • IJVBRONCH-2026-01

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIEZDECYDOWANY

Opis planu IPD

The plan for sharing de-identified individual participant data has not yet been finalized. A data-sharing decision will be made before publication, taking into account participant confidentiality, ethics committee requirements, institutional policies, and applicable data protection regulations.

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .