Assessing the Safety & Efficacy of an Affordable Fracture External Fixation System (AEFIX)
AEFIX Trial: A Multicenter, Open-Label, Randomized Pivotal (Phase III) Clinical Trial Assessing the Safety and Efficacy of a Novel, Affordable External Fixation System for the Management of Femur and Tibia Fractures in Adults
The goal of this clinical trial is to learn whether AEFIX, a new low-cost external fixation system, works as well as the external fixators currently used in Rwandan public hospitals to hold broken thigh (femur) and shin (tibia) bones in position in adults. External fixation uses metal pins placed into the bone and connected by clamps and rods outside the body. It is commonly used for severe fractures, including open fractures, that cannot safely be treated with internal plates or rods right away.
The main questions it aims to answer are:
- Does AEFIX keep the broken bone in position as well as standard external fixators, as measured on X-rays taken after surgery and again before the fixator is removed?
- How do complications, quality of life, and fracture healing compare between the two groups?
Researchers will compare AEFIX to the external fixation systems already used as standard care at each participating hospital to see whether AEFIX is no worse than these systems at keeping the bone in place.
Participants will:
- Be randomly assigned, like a coin toss, to receive either AEFIX or the standard external fixator during their planned fracture surgery
- Have X-rays after surgery and before the external fixator is removed
- Return for follow-up visits about 6 weeks, 3 months, 6 months, and 12 months after surgery, where the study team will check pin sites, healing, pain, and ability to bear weight, and ask questions about quality of life
- Receive reimbursement for transport costs to attend follow-up visits
About 150 adults will take part at up to five hospitals in Rwanda.
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Background Musculoskeletal trauma is common and rising in Rwanda, driven largely by road traffic injuries, and open fractures of the tibia are among the most frequent and serious injuries treated at referral hospitals. External fixation is the standard of care for temporary, and sometimes definitive, stabilization of fractures that cannot safely undergo internal fixation because of infection risk, soft tissue injury, or patient instability. Industry-standard external fixator clamps cost approximately 500 USD each, which limits their availability in public hospitals in low- and middle-income countries, where many fixators in use are donated or reprocessed. AEFIX is an affordable modular external fixation system (approximately 15 USD per clamp) made from medical-grade hard coat anodized aluminum and stainless steel. Laboratory mechanical testing has shown performance comparable to industry-standard clamps. This trial evaluates whether AEFIX is non-inferior to locally available external fixation systems in routine clinical practice in Rwanda.
Design This is a multicenter, pragmatic, open-label, parallel-arm randomized controlled trial with a non-inferiority design. Eligible participants are randomized 1:1 in the operating theatre, after final confirmation of eligibility, using a centralized web-based randomization system. Participants in the comparator arm receive the external fixation system routinely used at the participating site. The brand and model of each comparator construct, and whether components were previously used and reprocessed, are recorded for every participant, and each construct is photographed at application. Comparator systems at participating sites are predominantly Stryker Hoffmann 3. All participating surgeons complete a dedicated instructional course on the AEFIX technique before using the device.
Staged site activation Enrollment begins at the University Teaching Hospital of Kigali (CHUK) and the University Teaching Hospital of Butare (CHUB). Approximately the first 70 participants constitute an initial feasibility stage assessing recruitment rate (target of more than 3 participants per site per month), retention, and adherence to randomized allocation. Three district hospitals (Kabgayi, Kibagabaga, and Kibogora) will be activated following review of feasibility data by the independent Data and Safety Monitoring Committee (DSMC), or earlier if recruitment at CHUK and CHUB remains below target after three months of enrollment.
Sample size Assuming approximately 95% maintenance of fracture reduction in both arms, 74 participants (37 per arm) provide 90% power to demonstrate non-inferiority with a one-sided alpha of 0.05 and a non-inferiority margin of 15%. Allowing for up to 50% loss to follow-up, the trial will enroll 150 participants (75 per arm).
Statistical analysis The primary analysis follows the intention-to-treat principle and includes all comparator systems, reflecting routine practice. Per-protocol and as-treated analyses will assess robustness given the possibility of intraoperative device crossover. A pre-specified secondary analysis repeats the non-inferiority comparison among participants treated with AEFIX or Stryker Hoffmann 3, the predominant comparator, to provide a direct device-to-device comparison. Missing data will be handled by multiple imputation under a missing-at-random assumption, with sensitivity analyses. The trial biostatistician remains blinded to treatment allocation until database lock; the allocation key is held by an independent data manager with no role in outcome assessment or analysis.
Safety oversight An independent five-member DSMC with expertise in surgery, clinical research, research ethics, and biostatistics, based in Rwanda and the United States, meets quarterly and as needed. DSMC members have no financial relationship with the manufacturer of the investigational device or of the comparator devices. Causality of all adverse events is determined by the DSMC, independently of the study investigators and the device developer. Serious adverse device effects are reported to the Rwanda Food and Drugs Authority and the Rwanda National Research Ethics Committee in accordance with national requirements and ISO 14155:2020.
Conflict of interest The AEFIX device is developed and donated by SONA Global, a nonprofit organization founded by a study co-investigator, who receives no income, compensation, or equity from the organization.
Typ studiów
Typ studiów
Zapisy (Szacowany)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
Kontakt w sprawie studiów
- Nazwa: Jean de la Croix Allen Ingabire, MD, PhD
- Numer telefonu: +250 788 549 975
- E-mail: ijea2000@gmail.com
Kopia zapasowa kontaktu do badania
- Nazwa: Kiran Jay Agarwal-Harding, MD, MPH
- Numer telefonu: 240-506-4472
- E-mail: kahardin@bidmc.harvard.edu
Lokalizacje studiów
-
-
-
Huye, Rwanda
- University Teaching Hospital of Butare (CHUB)
-
Kontakt:
- Jean de la Croix Allen Ingabire, MD, PhD
- Numer telefonu: +250 788 549 975
- E-mail: ijea2000@gmail.com
-
Kigali, Rwanda
- University Teaching Hospital of Kigali (CHUK)
-
Kontakt:
- Jean Claude Byiringiro, MD
- Numer telefonu: +250 788 868 240
- E-mail: jcbyiringiro@gmail.com
-
Kontakt:
- Marie Grace Kansayisa, MD
- Numer telefonu: +250 788 503 841
- E-mail: gracekansayisa@gmail.com
-
Główny śledczy:
- Marie Grace Kansayisa, MD
-
Kigali, Rwanda
- Kibagabaga District Hospital
-
Kontakt:
- Jean de la Croix Allen Ingabire, MD, PhD
- Numer telefonu: +250 788 549 975
- E-mail: ijea2000@gmail.com
-
Muhanga, Rwanda
- Kabgayi District Hospital
-
Kontakt:
- Jean de la Croix Allen Ingabire, MD, PhD
- Numer telefonu: +250 788 549 975
- E-mail: ijea2000@gmail.com
-
Nyamasheke, Rwanda
- Kibogora District Hospital
-
Kontakt:
- Jean de la Croix Allen Ingabire, MD, PhD
- Numer telefonu: +250 788 549 975
- E-mail: ijea2000@gmail.com
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Age 18 years or older.
- Closed or open fracture of the femur and/or tibia, including fractures of the proximal femur, femoral diaphysis, extra-articular and intra-articular fractures of the distal femur and proximal tibia, tibial diaphysis, and extra-articular and intra-articular fractures of the distal tibia, including pilon and ankle fractures.
- Fracture not amenable to internal fixation due to risk of infection, inadequate soft tissue coverage, severe soft tissue trauma, or hemodynamic instability, and therefore indicated for external fixation by the treating surgeon.
- All planned surgeries to be performed by a participating surgeon or delegate at a study site (no pre-operative plan for transfer to another facility or surgeon after external fixation).
- Informed consent obtained from the patient or, if the patient is unable to consent because of their injury, from a healthcare proxy or legally authorized representative.
Exclusion Criteria:
- Established fracture malunion or nonunion, including any patient undergoing correction of deformity or management of a malunion, nonunion, or delayed union.
- Established chronic osteomyelitis or pathologic fracture.
- Limb deformity correction or bone transport.
- Periprosthetic fracture.
- Incarceration.
- Current enrollment in another study that does not permit co-enrollment.
- Unable to provide informed consent due to language barriers.
- Prior enrollment in this study.
- Fracture pattern or anatomical condition precluding safe placement of Schanz pins in established anatomical safe zones, as determined intraoperatively by the participating surgeon.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: AEFIX External Fixation
Participants receive fracture external fixation using the AEFIX system, an affordable modular external fixator consisting of AEFIX clamps (hard coat anodized aluminum), 11 mm aluminum connecting rods, and 5 mm Schanz pins. Components are steam sterilized on site before use. Pins are placed bicortically in anatomical safe zones and connected by clamps and rods in a unilateral double-rod or modular frame construct. The fixator remains in place until removal by the treating surgeon for staged conversion to internal fixation or after definitive treatment. |
Investigational modular external fixation system (clamps, connecting rods, and Schanz pins) designed for affordability in resource-limited settings. Clamps are made of medical-grade hard coat anodized aluminum and stainless steel, supplied non-sterile, and steam sterilized before single use. Manufactured by an ISO 13485-certified contract manufacturer for SONA Global. |
|
Aktywny komparator: Standard of Care External Fixation
Participants receive fracture external fixation using the locally available external fixation system routinely used as standard of care at the participating hospital, most commonly donated or reprocessed modular systems from established manufacturers (predominantly Stryker Hoffmann 3; also DePuy Synthes and others). The brand and model of each comparator construct, and whether components were previously used and reprocessed, are recorded for every participant, and each construct is photographed at application. The fixator remains in place until removal by the treating surgeon for staged conversion to internal fixation or after definitive treatment. |
Commercially available modular external fixation systems already in routine clinical use at participating hospitals, not supplied by the sponsor. Device brand, model, and reprocessing history are documented for each participant. |
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Loss of Fracture Reduction
Ramy czasowe: From initial postoperative radiograph (within 24 hours of external fixator application) to final radiograph (within 48 hours before external fixator removal), up to 12 months
|
Proportion of participants with loss of fracture reduction, defined as any of the following between the initial postoperative radiograph and the final radiograph before external fixator removal: angular deformity change greater than 5 degrees in the coronal or sagittal plane; translational displacement greater than 10 millimeters in any plane; or increase in fracture gap greater than 10 millimeters, measured using calibrated digital radiographic tools. Participants with more than one fracture treated with external fixation are counted as having loss of reduction if it occurs in any treated fracture. Non-inferiority of AEFIX relative to locally available external fixation systems is assessed using a pre-specified margin of 15% and a one-sided alpha of 0.05. |
From initial postoperative radiograph (within 24 hours of external fixator application) to final radiograph (within 48 hours before external fixator removal), up to 12 months
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of Participants With Clinical Complications, by Type
Ramy czasowe: 6 weeks, 3 months, 6 months, and 12 months after initial surgery
|
Clinical complications include pin tract infection, superficial infection, deep infection, iatrogenic neurovascular injury, malunion, nonunion, amputation, and death, reported as the number of participants experiencing each complication per treatment arm. |
6 weeks, 3 months, 6 months, and 12 months after initial surgery
|
|
Health-Related Quality of Life (EQ-5D-5L Index Score)
Ramy czasowe: 6 weeks, 3 months, 6 months, and 12 months after initial surgery
|
The EQ-5D-5L measures five dimensions of health (mobility, self-care, usual activities, pain/discomfort, anxiety/depression), each rated on five levels, and is summarized as an index score where 1 represents full health and 0 represents a state equivalent to death; values below 0 are possible. Higher scores indicate better health-related quality of life. A difference of 0.074 is considered the minimum clinically important difference. |
6 weeks, 3 months, 6 months, and 12 months after initial surgery
|
|
Functional Fracture Healing (Functional IndeX for Trauma [FIX-IT] Score)
Ramy czasowe: 6 weeks, 3 months, 6 months, and 12 months after initial surgery
|
The FIX-IT score assesses ability to bear weight (0 to 6 points) and pain at the fracture site (0 to 6 points), for a total score ranging from 0 to 12. Higher scores indicate better clinical fracture healing and function. A change of 2 or more points is considered clinically meaningful. |
6 weeks, 3 months, 6 months, and 12 months after initial surgery
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Główny śledczy: Jean de la Croix Allen Ingabire, MD, PhD, University of Rwanda
Publikacje i pomocne linki
Publikacje ogólne
- Momenzadeh K, Garcia MJ, Zhao L, Chainani P, Simister SK, Hua C, Miller T, Hontzsch D, Nazarian A, Agarwal-Harding KJ. Assessment of the Mechanical Performance of an Affordable External Fixator (AEFIX) Designed for Resource-Limited Settings. J Bone Joint Surg Am. 2025 Oct 15;107(20):2289-2299. doi: 10.2106/JBJS.24.01463. Epub 2025 Sep 3.
- Mpirimbanyi C, Abahuje E, Hirwa AD, Gasakure M, Rwagahirima E, Niyonzima C, Hakizimana AN, Ishimwe E, Ntirenganya F, Rickard J. Defining the Three Delays in Referral of Surgical Emergencies from District Hospitals to University Teaching Hospital of Kigali, Rwanda. World J Surg. 2019 Aug;43(8):1871-1879. doi: 10.1007/s00268-019-04991-3.
- Kwizera I, Byiringiro JC, Ingabire JCA, Murwanashyaka E, Mwizerwa JL. Assessment of applicability of Ganga Hospital Score in the management of open tibia fracture. Bone Jt Open. 2025 Apr 21;6(4):463-468. doi: 10.1302/2633-1462.64.BJO-2024-0207.R1.
- Agarwal-Harding KJ, Meara JG, Greenberg SL, Hagander LE, Zurakowski D, Dyer GS. Estimating the global incidence of femoral fracture from road traffic collisions: a literature review. J Bone Joint Surg Am. 2015 Mar 18;97(6):e31. doi: 10.2106/JBJS.N.00314.
- Agarwal-Harding KJ, von Keudell A, Zirkle LG, Meara JG, Dyer GS. Understanding and Addressing the Global Need for Orthopaedic Trauma Care. J Bone Joint Surg Am. 2016 Nov 2;98(21):1844-1853. doi: 10.2106/JBJS.16.00323.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Rozpoczęcie studiów
Zakończenie podstawowe (Szacowany)
Zakończenie podstawowe
Ukończenie studiów (Szacowany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- RNEC986/2025
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Opis planu IPD
De-identified individual participant data underlying the results reported in publications, including primary and secondary outcome data and baseline characteristics, will be made available to qualified researchers upon reasonable request. Data are owned by the University of Rwanda; sharing is subject to approval by the University of Rwanda and the Rwanda National Research Ethics Committee, compliance with Rwandan data protection law, and execution of a data use agreement.
Ramy czasowe udostępniania IPD
Beginning 6 months after publication of the primary results and ending 5 years after publication.
Kryteria dostępu do udostępniania IPD
Requests from qualified researchers with a methodologically sound proposal will be reviewed by the study investigators and the University of Rwanda. Approved requesters must sign a data use agreement prohibiting re-identification and limiting use to the approved proposal. Requests should be directed to the Principal Investigator.
Typ informacji pomocniczych dotyczących udostępniania IPD
- PROTOKÓŁ BADANIA
- SOK ROŚLINNY
- ICF
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .