Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Randomized Controlled Trial on Dimensional Changes Following Immediate Post-Extraction Implant Placement With a Gap ≥2 mm, With or Without Bone Regeneration Using a Xenograft.

20 listopada 2026 zaktualizowane przez: Miguel Gómez Polo

The goal of this clinical trial is to determine whether bone grafting is necessary for bone healing following immediate dental implant placement in adults aged 18 years or older who require extraction and replacement of a posterior tooth (premolar or molar) and have a gap of at least 2 mm between the implant and the surrounding buccal bone.

The main questions it aims to answer are:

  • Does placing a dental implant without a bone graft result in bone healing that is not clinically worse than placing an implant with a bone graft?
  • Are there differences in bone thickness, bone height, and changes in the width of the jawbone between the two treatment approaches? Researchers will compare immediate dental implant placement with a bone graft to immediate implant placement without a bone graft to evaluate bone healing and changes in the surrounding bone over 24 months.

Participants will:

  • Undergo tooth extraction and immediate placement of a dental implant, with or without a bone graft, according to random group assignment.
  • Receive a permanent implant-supported dental crown approximately 10 weeks after surgery.
  • Attend scheduled follow-up visits over 24 months for clinical examinations and assessment of implant health.
  • Undergo dental X-rays, three-dimensional cone-beam computed tomography (CBCT) scans, and digital intraoral scans to evaluate bone healing and changes in the tissues surrounding the implant.

Przegląd badań

Status

Rekrutacyjny

Warunki

Interwencja / Leczenie

Szczegółowy opis

This prospective, randomized, controlled, parallel-group, non-inferiority clinical trial aims to evaluate peri-implant bone healing and dimensional changes following immediate implant placement in posterior extraction sockets presenting a horizontal buccal gap ≥2 mm, with or without xenograft placement.

The study will be conducted at Clínica Santamaría (Madrid, Spain) and will include 34 adult participants requiring extraction and replacement of a single posterior tooth (premolar or molar). Each participant will contribute one implant and will be randomly allocated in a 1:1 ratio to one of two treatment groups: immediate implant placement with xenograft filling of the peri-implant gap (control group) or immediate implant placement without bone grafting (experimental group). Randomization will be performed using a computer-generated sequence, with allocation concealment maintained through sequentially numbered, opaque, sealed envelopes.

All participants will receive MultiNeO NH implants (Alpha-Bio Tec Ltd.), characterized by a superhydrophilic nanostructured surface. Surgical procedures will be performed by a single experienced surgeon following a standardized flapless approach. After atraumatic tooth extraction, implants will be placed in a prosthetically driven three-dimensional position, approximately 1 mm subcrestally, provided that adequate primary stability (≥35 Ncm) is achieved. The presence of an intact buccal bone wall and a horizontal peri-implant gap ≥2 mm will be confirmed intraoperatively.

In the control group, the peri-implant gap will be filled with a xenogeneic bone substitute (MatrixOss, Alpha-Bio Tec Ltd.), whereas in the experimental group, the gap will be left ungrafted. A healing abutment will be placed in both groups, allowing healing by secondary intention without primary soft tissue closure. An X-shaped suture will be used to stabilize the blood clot.

The clinical protocol will include nine scheduled visits: initial evaluation, surgical intervention, postoperative assessment at one week, clinical evaluation and digital impression at eight weeks, definitive prosthetic restoration at ten weeks, and follow-up assessments at 6, 12, 18, and 24 months. Definitive rehabilitation will consist of a screw-retained monolithic zirconia crown supported by a titanium base.

Radiographic evaluation will be performed using cone-beam computed tomography (CBCT) and standardized periapical radiographs. CBCT scans obtained at baseline, 6 months, and 24 months will be used to assess peri-implant bone healing and dimensional changes. Buccal bone thickness will be measured at the implant platform and at 1, 3, and 5 mm apical to the platform. Additional radiographic measurements will include buccal bone height, horizontal changes in alveolar ridge width, and the presence of complete or incomplete bone fill within the initial peri-implant gap. Marginal bone levels will be assessed using standardized periapical radiographs obtained at predefined follow-up visits.

Digital intraoral scans will be obtained during the prosthetic and follow-up phases to assess dimensional changes through superimposition of STL files. Clinical outcomes will include implant survival, peri-implant probing depth, bleeding on probing, plaque accumulation, peri-implant mucosal recession, and keratinized tissue or mucosa width.

Due to the nature of the interventions, blinding of the surgeon will not be possible. However, radiographic and digital measurements will be performed by independent, calibrated examiners blinded to treatment allocation. Clinical outcome assessments will also be performed by blinded examiners whenever feasible, and statistical analyses will be conducted using coded data.

The study follows a non-inferiority design with a predefined non-inferiority margin of 5%. The primary efficacy analysis will be conducted in the per-protocol population, while the intention-to-treat population will be used primarily for safety analyses. Sensitivity analyses will be performed to evaluate the potential impact of missing data.

The findings are expected to provide evidence regarding the necessity of xenograft placement in immediate posterior implant sites with a horizontal buccal gap ≥2 mm and to support clinical decision-making concerning peri-implant bone regeneration.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

17

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

  • Nazwa: Miguel Gómez Polo, DDS, PhD
  • Numer telefonu: +34913942029
  • E-mail: mgomezpo@ucm.es

Kopia zapasowa kontaktu do badania

  • Nazwa: Angel Garcia Cañas, DDS, MSc
  • Numer telefonu: +34 638 26 61 53
  • E-mail: Angelg23@ucm.es

Lokalizacje studiów

    • Madrid
      • Madrid, Madrid, Hiszpania, 28040
        • Rekrutacyjny
        • Clínica Universitaria de Odontología, Universidad Complutense de Madrid
        • Kontakt:
          • Angel Garcia Cañas, DDS, MSc
          • Numer telefonu: +34 638 26 61 53
          • E-mail: Angelg23@ucm.es
        • Kontakt:
          • Miguel Gómez Polo, DDS, PhD
          • Numer telefonu: +34 913942029
          • E-mail: mgomezpo@ucm.es

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dziecko
  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  • Patients aged 18 years or older, partially edentulous, requiring replacement of a single tooth in the posterior region (premolar or molar) by means of immediate post-extraction implant placement.
  • Presence of a post-extraction socket with a horizontal buccal gap ≥2 mm, confirmed intraoperatively after implant placement.
  • Intact buccal bone wall (without dehiscence or fenestration), clinically confirmed after tooth extraction.
  • Clinical conditions allowing adequate primary implant stability to be achieved (≥35 Ncm).
  • Patients classified as ASA I or ASA II according to the American Society of Anesthesiologists classification.
  • Patients who understand the nature of the study, sign the informed consent form, and agree to attend all scheduled follow-up visits over the 24-month study period.
  • Availability to undergo the radiographic assessments (CBCT and periapical radiographs) required by the study protocol.

Exclusion Criteria:

  • Patients classified as ASA III or ASA IV, or with uncontrolled systemic diseases that may interfere with bone healing or clinical follow-up.
  • Presence of uncontrolled acute infection at the extraction site that contraindicates immediate implant placement.
  • Buccal bone defects involving loss of the buccal bone wall (dehiscence or fenestration).
  • Need for additional regenerative procedures other than those established in the study protocol.
  • Treatment with medications that may significantly affect bone metabolism (e.g., intravenous bisphosphonates or immunosuppressive agents).
  • Pregnancy or breastfeeding.
  • Heavy smoking (according to the threshold defined in the study protocol).
  • Inability to comply with the scheduled follow-up visits or complete the required assessments.
  • Any condition that, in the investigator's judgment, may compromise adherence to the study protocol, data validity, or patient well-being.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Pojedynczy

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: Immediate Implant Placement With Xenograft

Participants allocated to the control group will undergo atraumatic tooth extraction followed by immediate placement of a MultiNeO NH implant (Alpha-Bio Tec Ltd.) in a posterior extraction socket with an intact buccal bone wall and a horizontal buccal gap ≥2 mm. The peri-implant gap will be filled with a xenogeneic bone substitute (MatrixOss, Alpha-Bio Tec Ltd.). A healing abutment will be placed, and healing will occur by secondary intention. Definitive restoration with a screw-retained monolithic zirconia crown will be performed approximately 10 weeks after surgery. Participants will be followed for 24 months.

Atraumatic extraction of a posterior tooth followed by immediate placement of a MultiNeO NH implant (Alpha-Bio Tec Ltd.) using a flapless surgical approach. Following confirmation of an intact buccal bone wall and a horizontal peri-implant gap ≥2 mm, the gap will be filled with a xenogeneic bone substitute (MatrixOss, Alpha-Bio Tec Ltd.). The implant will be positioned approximately 1 mm subcrestally, with a minimum insertion torque of 35 Ncm. A healing abutment and an X-shaped suture will be placed, allowing healing by secondary intention without primary soft tissue closure.

Eksperymentalny: Immediate Implant Placement Without Xenograft

Participants allocated to the experimental group will undergo atraumatic tooth extraction followed by immediate placement of a MultiNeO NH implant (Alpha-Bio Tec Ltd.) in a posterior extraction socket with an intact buccal bone wall and a horizontal buccal gap ≥2 mm. No bone grafting material will be placed in the peri-implant gap, allowing spontaneous bone healing. A healing abutment will be placed, and healing will occur by secondary intention. Definitive restoration with a screw-retained monolithic zirconia crown will be performed approximately 10 weeks after surgery. Participants will be followed for 24 months.

Atraumatic extraction of a posterior tooth followed by immediate placement of a MultiNeO NH implant (Alpha-Bio Tec Ltd.) using a flapless surgical approach. Following confirmation of an intact buccal bone wall and a horizontal peri-implant gap ≥2 mm, the peri-implant gap will be left ungrafted to allow spontaneous bone healing. The implant will be positioned approximately 1 mm subcrestally, with a minimum insertion torque of 35 Ncm. A healing abutment and an X-shaped suture will be placed, allowing healing by secondary intention without primary soft tissue closure.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Peri-Implant Buccal Bone Thickness (BBT)
Ramy czasowe: 6 and 24 months after implant placement

Buccal bone height will be measured as the vertical distance between the implant platform and the most coronal point of the buccal bone in contact with or in close proximity to the buccal implant surface. Measurements will be performed on standardized CBCT cross-sectional slices oriented along the long axis of the implant. Values will be expressed in millimeters (mm).

6 and 24 months after implant placement

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Buccal Bone Height (BBH)
Ramy czasowe: 6 and 24 months after implant placement

Buccal bone height will be measured as the vertical distance between the implant platform and the most coronal point of the buccal bone in contact with or in close proximity to the buccal implant surface. Measurements will be performed on standardized CBCT cross-sectional slices oriented along the long axis of the implant. Values will be expressed in millimeters (mm).

6 and 24 months after implant placement
Horizontal Changes in Alveolar Ridge Width (RW)
Ramy czasowe: Baseline, 6 and 24 months after implant placement

Alveolar ridge width will be measured as the horizontal distance between the outer buccal bone contour and the outer lingual/palatal bone contour on standardized CBCT cross-sectional slices at predefined reproducible anatomical reference levels. Dimensional changes will be calculated as follow-up ridge width minus baseline ridge width (ΔRW). Results will be expressed in millimeters (mm) and may also be expressed as percentage change relative to baseline (%).

Baseline, 6 and 24 months after implant placement
Complete Peri-Implant Gap Bone Fill
Ramy czasowe: 6 and 24 months after implant placement

Bone fill within the region corresponding to the initial buccal peri-implant gap will be assessed using standardized CBCT cross-sectional slices oriented along the long axis of the implant. Radiographic bone continuity within the initial gap region will be evaluated and classified as a dichotomous outcome: complete bone fill (Yes) or incomplete bone fill (No).

6 and 24 months after implant placement
Implant Survival Rate
Ramy czasowe: 10 weeks and 6, 12, 18 and 24 months after implant placement

Implant survival will be defined as the presence of the implant in situ and in function, regardless of biological or prosthetic complications that have not required implant removal. Survival will be recorded as a dichotomous variable (Yes/No) through clinical examination and review of clinical records. The cumulative survival rate will be expressed as the percentage of implants remaining in situ relative to the total number of implants in each group. Implant loss, date, and cause will be recorded when available.

10 weeks and 6, 12, 18 and 24 months after implant placement
Peri-Implant Probing Depth (PPD)
Ramy czasowe: 10 weeks and 6, 12, 18 and 24 months after implant placement

Bleeding on probing will be assessed immediately following gentle peri-implant probing at six sites per implant. Bleeding will be recorded at each site using a binary score: 0 = absence of bleeding and 1 = presence of bleeding. The percentage of bleeding-positive sites per implant will be calculated as the number of sites with bleeding divided by six, multiplied by 100. Suppuration, when present, will be recorded separately.

10 weeks and 6, 12, 18 and 24 months after implant placement
Peri-Implant Plaque Index
Ramy czasowe: 10 weeks and 6, 12, 18 and 24 months after implant placement

Plaque accumulation around the implant-supported restoration will be assessed by clinical inspection and gentle probing at six peri-implant sites. Plaque presence will be recorded using a binary score: 0 = no detectable plaque and 1 = detectable plaque. The percentage of plaque-positive sites per implant will be calculated as the number of sites with detectable plaque divided by six, multiplied by 100.

10 weeks and 6, 12, 18 and 24 months after implant placement
Peri-Implant Mucosal Recession
Ramy czasowe: 10 weeks and 6, 12, 18 and 24 months after implant placement

Peri-implant mucosal recession will be assessed at the mid-buccal site by measuring the vertical distance between the mucosal margin and a fixed, reproducible prosthetic reference point on the definitive restoration. Recession will be defined as the apical displacement of the mucosal margin relative to its position at definitive restoration placement. Absolute measurements and changes from the prosthetic baseline will be recorded in millimeters (mm).

10 weeks and 6, 12, 18 and 24 months after implant placement
Keratinized Tissue/Mucosa Width (KTW/KMW)
Ramy czasowe: Baseline and scheduled follow-up visits through 24 months

At the pre-extraction baseline, keratinized tissue width (KTW) will be measured from the mid-buccal gingival margin of the natural tooth to the mucogingival junction. Following implant placement, keratinized mucosa width (KMW) will be measured from the mid-buccal peri-implant mucosal margin to the mucogingival junction using a calibrated periodontal probe. The mucogingival junction will be identified clinically, with the roll test when necessary. Values will be recorded in millimeters (mm). Changes relative to baseline will be considered exploratory.

Baseline and scheduled follow-up visits through 24 months
Marginal Bone Level Changes (MBL)
Ramy czasowe: Immediately after implant placement; 8 and 10 weeks; 6, 12, 18 and 24 months

Marginal bone level will be measured as the vertical distance between the implant platform/shoulder and the first radiographically identifiable bone-to-implant contact at the mesial and distal implant aspects. Standardized periapical radiographs obtained using the paralleling technique will be used, with calibration when necessary. Mesial, distal, and mean marginal bone levels will be recorded in millimeters (mm). Longitudinal changes (ΔMBL) will be calculated relative to the radiographic baseline at definitive restoration placement. The immediate postoperative radiograph will serve as an additional surgical reference.

Immediately after implant placement; 8 and 10 weeks; 6, 12, 18 and 24 months

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Współpracownicy

Śledczy

  • Dyrektor Studium: Miguel Gómez Polo, DDS, MSc, Complutense University od Madrid
  • Główny śledczy: Angel Garcia Cañas, DDS, MSc, Universidad Complutense de Madrid

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Publikacje ogólne

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

1 sierpnia 2026

Zakończenie podstawowe (Szacowany)

1 kwietnia 2028

Ukończenie studiów (Szacowany)

1 lutego 2029

Daty rejestracji na studia

Pierwszy przesłany

20 listopada 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

20 listopada 2026

Pierwszy wysłany (Rzeczywisty)

27 listopada 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

27 listopada 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

20 listopada 2026

Ostatnia weryfikacja

1 listopada 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 26/397-EC_X

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Opis planu IPD

Individual participant data will not be made publicly available due to patient confidentiality and data protection considerations. Study results will be reported in aggregate form through scientific publications.

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .