Hemodynamic Responses of Different Laryngoscopes
Comparison of Different Laryngoscopes in Terms of Hemodynamic Responses
During laryngoscopy and endotracheal intubation, stimulation of supraglottic regions leads to an increase in the plasma catecholamine concentrations due to the activation of the sympatho-adrenal system. Prevention or reduction of this increment is important for hemodynamic control. Therefore, various methods such as providing adequate depth of anesthesia and shortening the time of laryngoscopy were used. On the other hand; alternative laryngoscopy devices and techniques have recently started to be used.
In this randomized single blind study, the aim is to compare the hemodynamic responses of four different laryngoscopy techniques with Macintosh laryngoscope, McCoy laryngoscope, C-Mac videolaryngoscope and McGrath videolaryngoscope in patients with normal predictive airway.
Обзор исследования
Статус
Подробное описание
During laryngoscopy and endotracheal intubation, stimulation of supraglottic regions leads to an increase in the plasma catecholamine concentrations due to the activation of the sympatho-adrenal system. Prevention or reduction of this increment is important for hemodynamic control. Therefore, various methods such as providing adequate depth of anesthesia and shortening the time of laryngoscopy were used. On the other hand; alternative laryngoscopy devices and methods have recently started to be used.
In this randomized single blind study, our aim is to compare the hemodynamic responses of four different laryngoscopy techniques with Macintosh laryngoscope, McCoy laryngoscope, C-Mac videolaryngoscope and McGrath videolaryngoscope in patients with normal predictive airway.
After obtaining Institutional Ethics Committee approval and patient consents, 170 patients (18-65 years old) with ASA I-II status requiring general anesthesia with endotracheal intubation, were enrolled to this prospective randomized study.
Besides routine monitorization (noninvasive blood pressure (NIBP), electrocardiography (ECG), heart rate (HR), peripheral oxygen saturation (SPO2)), continuous BIS monitorization was also performed. Sedation was performed using a standard dose of IV fentanyl (1.5 μg/kg) and midazolam (0.05 mg/kg). Baseline systolic, diastolic and mean arterial blood pressures, HR and SPO2 values were recorded as T0. After a stabilization period of 10 minutes, propofol 2-3 mg/kg IV bolus was applied incrementally until a clinically desirable sedation level was achieved. If necessary, additional propofol boluses were given to maintain a BIS level of 60. As soon as BIS level was reduced to 60, patients were put on 0.6 mg/kg IV rocuronium. 100% oxygen was applied with a facemask for a period of 3 minutes. Then, post induction values (T1) were recorded.
One hundred seventy patients were randomly allocated equally to Macintosh laryngoscope, Mc-Coy laryngoscope, C-Mac videolaryngoscope and McGrath videolaryngoscope groups. Endotracheal tube (ETT) of 7.0 mm and 7.5 mm were placed to female and male patients, respectively. All intubation procedures were performed by a single experienced anesthesiologist. Intubation stylet was provided, if necessary. Cuff pressures of endotracheal tubes were standartized to 30 cmH2O via a manometer. The following measurements were recorded immediately after intubation (T2) and at one minute intervals for 5 minutes (T3, T4, T5, T6 and T7).
Moreover; the number of intubation attempts, stylet needs, Cormack-Lehane scales, and the complications occurred during intubation procedures were recorded as the second outcomes. Patients were also questioned for possible sore throat at postoperative 2 hours. Patients requiring more than one attempt to achieve successful intubation were excluded from statistical analysis of data.
Тип исследования
Регистрация (Действительный)
Фаза
- Фаза 4
Контакты и местонахождение
Места учебы
-
-
-
Istanbul, Турция, 34093
- Istanbul University, Department of anesthesiology
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- Patients with ASA I-II status, requiring general anesthesia with endotracheal intubation
Exclusion Criteria:
- ASA status higher than II, a history or suspected of difficult airway, hypertansion, under treatment known to affect blood pressure or heart rate (Beta blocker/ Ca-channel blocker), BIS value > 60
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Скрининг
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Одинокий
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Активный компаратор: Macintosh laryngoscope
Endotracheal intubation with classic (Macintosh) laryngoscope
|
Hemodynamic parameters after endotracheal intubation with Classic laryngoscope (Macintosh)
|
|
Активный компаратор: Mc-Coy laryngoscope
Endotracheal intubation with Mc-Coy laryngoscope
|
Hemodynamic parameters after endotracheal intubation with Mc-Coy laryngoscope
|
|
Активный компаратор: C-Mac videolaryngoscope
Endotracheal intubation with C-Mac videolaryngoscope
|
Hemodynamic parameters after endotracheal intubation with C-Mac videolaryngoscope
|
|
Активный компаратор: McGrath videolaryngoscope
Endotracheal intubation with McGrath videolaryngoscope
|
Hemodynamic parameters after endotracheal intubation with McGrath videolaryngoscope
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Arterial blood pressure
Временное ограничение: Change from baseline in blood pressures at first 20 minutes
|
Hemodynamic parameters as systolic, diastolic and mean arterial blood pressures were recorded during and after induction
|
Change from baseline in blood pressures at first 20 minutes
|
|
Heart rate
Временное ограничение: Change from baseline in heart rates at first 20 minutes
|
Hemodynamic parameters as heart rates were recorded during and after induction
|
Change from baseline in heart rates at first 20 minutes
|
|
SPO2 value
Временное ограничение: Change from baseline in SPO2 values at first 20 minutes
|
Hemodynamic parameters as SPO2 values were recorded during and after induction
|
Change from baseline in SPO2 values at first 20 minutes
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Number of intubation attempts
Временное ограничение: During endotracheal intubation
|
Number of intubation attempts were recorded
|
During endotracheal intubation
|
|
Stylet need
Временное ограничение: During endotracheal intubation
|
Stylet need was recorded
|
During endotracheal intubation
|
|
Cormach-Lehane scales
Временное ограничение: During endotracheal intubation
|
Cormack-Lehane scales were recorded
|
During endotracheal intubation
|
|
Complications
Временное ограничение: During endotracheal intubation
|
Possible complications were recorded
|
During endotracheal intubation
|
|
Sore throat
Временное ограничение: Postoperative 2 hours
|
Possible sore throat was recorded
|
Postoperative 2 hours
|
Соавторы и исследователи
Спонсор
Следователи
- Главный следователь: Demet Altun, MD, Istanbul University, Department of Anesthesiology an Reanimation
Даты записи исследования
Изучение основных дат
Начало исследования
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Оценивать)
Обновления учебных записей
Последнее опубликованное обновление (Оценивать)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- 2014/1191
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .
Клинические исследования Macintosh laryngoscope
-
Aga Khan UniversityЗавершенный
-
Hitit UniversityIzmir City HospitalЗавершенныйЭндотрахеальная интубация | Управление дыхательными путями | Интубация трахеи, плановая хирургияТурция (Туркие)
-
AnestesiaRНеизвестныйОжирение | Эндотрахеальная интубация | Вентиляция | ДесатурацияИспания
-
Imam Abdulrahman Bin Faisal UniversityMansoura UniversityЗавершенный
-
The University of Texas Health Science Center,...KARL STORZ Endoscopy-America, Inc.ЗавершенныйИнтубация, эндотрахеальнаяСоединенные Штаты
-
University of the Basque Country (UPV/EHU)НеизвестныйНарушение дыхания | Сложная интубация | Остановка сердца | Осложнение интубации анестезииИспания
-
Alexandria UniversityЗавершенныйНеблагоприятные эффекты эндотрахеальной интубацииЕгипет
-
Van Bölge Eğitim ve Araştırma HastanesiЗавершенный
-
Johannes Gutenberg University MainzWestern University, Canada; Mutterhaus der Borromäerinnen, Germany; Christophorus Hospital...ЗавершенныйОценка видеоларингоскопии (Video Macintosh-лезвие) и прямой ларингоскопии (EMMA-исследование) (EMMA)Заболеваемость дыхательных путейГермания
-
Glostrup University Hospital, CopenhagenЗавершенныйОжирение | Анестезия, общая | Интубация, эндотрахеальнаяДания