Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness†
J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier, J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier
Abstract
Background: Dynamic indices, such as pulse pressure variation (PPV), are inaccurate predictors of fluid responsiveness in mechanically ventilated patients with low tidal volume. This study aimed to test whether changes in continuous cardiac index (CCI), PPV, and stroke volume variation (SVV) after a mini-fluid challenge (100 ml of fluid during 1 min) could predict fluid responsiveness in these patients.
Methods: We prospectively studied 49 critically ill, deeply sedated, and mechanically ventilated patients (tidal volume <8 ml kg(-1) of ideal body weight) without cardiac arrhythmias, in whom a fluid challenge was indicated because of circulatory failure. The CCI, SVV (PiCCO™; Pulsion), and PPV (MP70™; Philips) were measured before and after 100 ml of colloid infusion during 1 min, and then after the additional infusion of 400 ml during 14 min. Responders were defined as subjects with a ≥15% increase in cardiac index (transpulmonary thermodilution) after the full (500 ml) fluid challenge. Areas under the receiver operating characteristic curves (AUCs) and the grey zones were determined for changes in CCI (ΔCCI100), SVV (ΔSVV100), and PPV (ΔPPV100) after 100 ml fluid challenge.
Results: Twenty-two subjects were responders. The ΔCCI100 predicted fluid responsiveness with an AUC of 0.78. The grey zone was large and included 67% of subjects. The ΔSVV100 and ΔPPV100 predicted fluid responsiveness with AUCs of 0.91 and 0.92, respectively. Grey zones were small, including ≤12% of subjects for both indices.
Conclusions: The ΔSVV100 and ΔPPV100 predict fluid responsiveness accurately and better than ΔCCI100 (PiCCO™; Pulsion) in patients with circulatory failure and ventilated with low volumes.
Keywords: cardiac output; fluid therapy; goal-directed therapy; haemodynamics; monitoring; pulse pressure.
© The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Source: PubMed
即将进行的临床试验
-
NCT07680075尚未招聘
-
NCT07680101尚未招聘
-
NCT07680140尚未招聘氯胺酮 | 功能磁共振成像 | 抑郁症 - 重度抑郁症 | 经颅磁刺激 | 难治性抑郁症 (TRD)
-
NCT07680153尚未招聘功能磁共振成像 | 双相情感障碍 (BD) | 经颅磁刺激 | 双极 1 抑郁症
-
NCT07680205招聘中嗜铬细胞瘤 | 嗜铬细胞瘤/副神经节瘤 | 嗜铬细胞瘤,转移性 | 嗜铬细胞瘤恶性 | 嗜铬细胞瘤和paraganglioma(PPGL)
-
NCT07680244招聘中视网膜前膜 | 视网膜疾病 | 干性年龄相关性黄斑变性 | 玻璃体视网膜异常 | Macular Abnormalities | Intraretinal Hyporeflective Space | Subretinal Hyporeflective Space | IS/OS (Ellipsoid Zone) Disruption | Retinal Pigment Epithelium (RPE) Elevation | Retinal Pigment Epithelium (RPE) Atrophy